REFUsol 50K-3T

REFUsol 50K-3T

REFUsol 50K-3T

Product catalog summary
Overview: The REFUsol 50K-3T inverter is designed for flexibility in commercial and industrial photovoltaic (PV) systems. It features multi-MPP tracking, a separate connection area, and is part of the new REFUsol series. With a 50 kVA output power, it is suitable for various project sizes and can be installed on rooftops or ground-mounted systems.
Specifications: The inverter supports a maximum recommended PV power of 66.5 kWp and a maximum input voltage of 1,000 V. It operates within an input voltage range of 250 to 960 V and has three independent MPP trackers. The AC data includes a rated power of 50 kW, a nominal grid voltage of 220/380 V or 230/400 V, and a maximum output current of 80 A. The inverter's efficiency is high, with a maximum efficiency of 98.5% and a weighted efficiency of 98.3%.
Protection and Safety: The inverter includes integrated DC switches and safety protections such as anti-islanding, DC reverse polarity, overtemperature, overvoltage, and overcurrent protection. It is equipped with surge protection devices type II on the DC side and has a protection class of I with an overvoltage category of DC: Type II standard and AC: Type III standard.
Communication and Monitoring: The REFUsol 50K-3T supports RS485 communication and has an SD card slot. Ethernet and WiFi connectivity are optional. The REFUlog monitoring portal is available for free during the 5-year warranty period.
Environmental and Physical Characteristics: The inverter operates in ambient temperatures ranging from -25°C to +60°C, with derating above 45°C. It has an IP65 protection degree, allowing for operation in various environmental conditions. The inverter measures 737 x 713 x 297 mm and weighs 66.5 kg.
Certifications: The inverter complies with several standards, including EN 61000-6-2, EN 61000-6-4, IEC62109-1/2, and VDE 0126, among others.
See more

Catalog excerpts

REFUsol 50K-3T-1

REFUsol 50K-3T The power for mid-size PV plants Multi MPP-Tracking Separate connection area The completely new REFUsol inverter is developed for a maximum of flexibility in commercial and industrial PV systems. With three MPP trackers, each system design can be realized, including different orientations and tilts. Compact dimensions paired with a high power density per weight gives more installation location flexibility – on the rooftop or on ground mounted systems. With 50 kVA output power, it fits to any project size. The inverters can be connected on the same RS485 Bus for monitoring and Park Control applications without the need for reconfiguration. Therefore, the devices are also best suited for extending existing PV plants equipped with legacy REFUsol inverters. Surge protection devices type II are pre-equipped on the DC side for additional protection. Four digital inputs support the feed-in management (i.e. 0 %, 30 %, 60 %, 10 0%). The REFUlog monitoring portal comes for free with each inverter during the warranty period of 5 years. The Ethernet Stick for internet connection is supplied as standard, a WiFi Stick can be ordered

 Open the catalog to page 1
REFUsol 50K-3T-2

TECHNICAL DATA DC DATA Max. recommended PV power (kWp) Max. input voltage (V) Operating input voltage range (V) Start-up input voltage (V) Rated input voltage (V) Number of independent MPPT Number of DC inputs per MPPT Rated power MPPT voltage range (V) Max. short circuit current per MPPT (A) AC DATA Rated power (kW) Nominal grid voltage (V) Nominal grid frequency (Hz) Max output current (A) Total harmonic distortion (THD) (%) Adjustable power factor range AC Connection <3 0.8 inductive … 0.8 capacitive ring cable lugs (M8) EFFICIENCY DIAGRAM Rated Output Power

 Open the catalog to page 2
REFUsol 50K-3T-3

Weighted efficiency (EU/CEC) (%) Feed-in start power (W) MPPT efficiency Safety protection Anti-islanding, DC reverse polarity, Overtemperature, Overvoltage, Overcurrent, RCMU, ground fault protection String monitoring each MPPT String fuses Protection class / overvoltage category External environment pollution degree Max. inverter back-feed current to the array (A) Class I / DC: Type II standard, AC: Type III standard 3 < 6 mA Output short circuit current (A) Output inrush current (A) COMMUNICATION Digital inputs GENERAL DATA Ambient temperature range (°C) Topology Degree of protection Allowable...

 Open the catalog to page 3
REFUsol 50K-3T-4

SINGLE LINE DIAGRAM 1 DC switch 2 DC+ connectors 3 DC- connectors 4 Relay contact 5 RS 485 input cable gland 6 RS 485 output cable gland 7 Ethernet / WiFi / GPRS connector 8 AC cable gland 9 Anti-condensation valve 10 Fans 11 Wall mount PERFORMANCE DIAGRAMS No responsibility is taken for the correctness of this information. Subject to modification. REFU Elektronik GmbH | Marktstraße 185 | 72793 Pfullingen | Germany | Tel. +49 7121 4332-0 | Fax +49 7121 4332-140 | [email protected] | www.refu.com Output Power vs. Grid Voltage Output Power vs. Input V