Group: reer
Catalog excerpts
SENSORS safety contactless sensors and devices product catalogue
Open the catalog to page 1OVERVIEW PI-Safe Fail-safe inductive sensors. See page 4 Contactless RFID Safety Switches. See Page 9 22 mm interaxis Highly visible status LED 3 different coding levels Models R-SAFE RFID Plus (with M12 8 poles) R-SAFE RFID Pro (with M12 8 poles) R-SAFE RFID Basic (with M12 5 poles) M12 connector, Pigtail with M12 connector, 1, 3, 5 or 10 metres cable Anti-tampering protection caps SAFETY CONTACTLESS SENSORS AND DEVICES
Open the catalog to page 2Magnetic safety switches. See page 15 Type 2 safety photocells. See page 17 Type 2 safety photocells. See page 18 Safety Sin/Cos incremental encoder. See page 19 Safety switch with guard locking. See page 21 SAFETY CONTACTLESS SENSORS AND DEVICES
Open the catalog to page 3PI-Safe OVERVIEW The operating principle and thus the advantages of inductive sensors can be used for safety applications. Inductive safety applications are special applications which require a non-contact and safe detection of a metal object. A wear-free function due to the non-contact principle together with a high protection rating, guarantee a high uptime of machines and installations. The PI-Safe sensor increases the uptime and safety of installations and can be connected to approved evaluation units without cross-fault monitoring. Fail-safe inductive sensors A complete range of...
Open the catalog to page 4PI-Safe SAFETY LEVEL METAL THREAD M12 X 1 / L = 70 MM TECHNICAL FEATURES Mounting Housing material Enable zone (mm) Operating voltage (VDC) Current consumption (mA) Max. capacitive load (nF) Short-circuit protection Response time (ms) Non-flush mountable Body: stainless steel; Head: PBT 0,5 ... 4 19,2 ... 30 < 20 20 yes ≤1 ACCESSORIES ■ M12 angle bracket or M12 mounting clamp. See page 8 ■ M12 5-pole straight connectors. See page 26 METAL THREAD M18 X 1 / L = 70,5 MM SAFETY LEVEL TECHNICAL FEATURES Mounting Housing material Enable zone (mm) Operating voltage (VDC) Current consumption (mA)...
Open the catalog to page 5PI-Safe PI M18 FR SAFETY LEVEL TECHNICAL FEATURES Mounting Housing material Enable zone (mm) Operating voltage (VDC) Current rating (mA) Current consumption (mA) Max. capacitive load (nF) Short-circuit protection Response time (ms) SAFETY LEVEL ACCESSORIES ■ M18 angle bracket or M18 mounting clamp. See page 8 ■ M12 5-pole straight connectors. See page 26 METAL THREAD M30 X 1,5 / L = 70 MM TECHNICAL FEATURES Mounting Housing material Enable zone (mm) Operating voltage (VDC) Current rating (mA) Current consumption (mA) Max. capacitive load (nF) Short-circuit protection Response time (ms)...
Open the catalog to page 6PI-Safe PI M30 NF K SAFETY LEVEL High protection class IP69K for use in harsh environments. SAFETY LEVEL METAL THREAD M30 X 1,5 / L = 80 MM TECHNICAL FEATURES Mounting Response time (ms) Enable zone (mm) Operating voltage (VDC) Current rating (mA) Current consumption (mA) Max. capacitive load (nF) Short-circuit protection Housing material Non-flush mountable ≤ 10 6 ... 12 19,2 ... 30 100 < 30 20 yes Body: stainless steel; Head: PBT ACCESSORIES ■ M30 angle bracket or M30 mounting clamp. See page 8 ■ M12 5-pole straight connectors. See page 26 RECTANGULAR 40X40X66 MM TECHNICAL FEATURES...
Open the catalog to page 7PI-Safe ACCESSORIES ANGLE BRACKET CLAMPS WITH END STOP ■ For mounting cylindrical sensors ■ Easy, quick and inexpensive fixing ■ End stop for defined installation position ■ Safe fixing of the sensor with click-fit mounting ■ Robust stainless steel design for use in harsh ■ Easy, quick and inexpensive fixing ■ Reliable mounting on a surface by means of two industrial environments ■ Reliable mounting on a surface by means of two Ordering code Ordering code CABLES NEEDED ■ M12 straight connector 5-pole for all models. See page 26
Open the catalog to page 8TECHNICAL CHARACTERISTICS Electrical specifications Supply voltage (VDC) Power consumption (W) Switching current safety output (mA) Switching current status output (mA) Safety outputs 2 OSSD active high Safety inputs Status output 2 inputs active high 1 output active high Monitored normally open Restart input in series with EDM R-Safe RFID Basic (with M12 5 poles) R-Safe RFID Pro (with M12 8 poles) R-Safe RFID Plus (with M12 8 poles) Safety switches for position control of movable guards. ■ RFID technology ■ 22 mm interaxis ■ IP65, IP67 and IP69K protection degree ■ Three types of...
Open the catalog to page 9MODELS Basic models Plus models Automatic restart without EDM Automatic restart with EDM Selectable Automatic/Manual restart with EDM Automatic restart without EDM Selctable Automatic/manual restart without EDM Digital inputs for series connection, thought OSSD outputs Digital inputs for series connection, thought OSSD outputs Individual status signal for each sensor (not serialisable) Serialisable status signal with individual status indication for each sensor Note: operating mode is selected by different wiring configurations. 2 Inputs available on R-Safe Plus and R-Safe Pro models only *...
Open the catalog to page 10CODE LEGEND (ORDERING INFORMATION) RRFID BASIC Model PRO Model PLUS Model C C M12 connector P M12 Pigtail connector 1 Cable 1 m 3 Cable 3 m 5 Cable 5 m X Cable 10 m C Combo S Sensor A Actuator G Generic coding T Teach-In coding U Unique coding CONNECTION Basic model pin-out 2 5 3 Plus model pin-out 1 - 24 VDC 6 2 - OSSD Safety input 1 for serial connection 5 3 - 0 Vcc 4 - Safety output 1 4 5 - Diagnostic output 6 - OSSD Safety input 2 for serial connection 7 - Safety output 2 8 - EDM input 1 - 24 VDC 6 2 - OSSD Safety input 1 for serial connection 5 3 - 0 Vcc 4 - Safety output 1 4 5 -...
Open the catalog to page 11SERIES CONNECTION PRO MODELS Up to PL e Performance Level according to EN ISO 13849-1 Splitter connector CRY12 - A* 5 poles 5 poles Auxiliary power supply Status output Status output Status output ACCESSORIES (for series connection) CRY12 - A [1292404] Used to connect the status signal CRY12 - C [1292405] Used for auxiliary power supply CRY12 - B [1292403] for the last sensor of the serie * In a serial connection where the use of the "Status" signal or external relay control (EDM) is required, the use of the CRY12 - A, CRY12 - B, CRY12 -TP splitter connectors is recommended. If the length...
Open the catalog to page 12All REER catalogs and technical brochures
-
Safety interfaces
7 Pages
-
SAFELOCK
4 Pages
-
SV MR0 - Brochure
4 Pages
-
PI-Safe
7 Pages
-
MICRON - Brochure
32 Pages
-
Brochure_MZERO_ENG_WebMail
4 Pages
-
SAFEGATE - Brochure
60 Pages
-
EOS
56 Pages
-
Panorama Catalogue
48 Pages
-
EOS4
7 Pages
Archived catalogs
-
Panorama Catalogue_2021
36 Pages
-
EOS - Brochure
7 Pages
-
MOSAIC - Brochure
5 Pages
-
Brochure JANUS
1 Pages
-
Brochure MAGNUS
2 Pages
-
ATEX Safety light curtains
2 Pages
-
SAFETY INCREMENTAL ENCODER
2 Pages
-
Mosaic - Leaflet
2 Pages
-
SAFETY RELAYS
2 Pages