video corpo

METRON
28Pages

{{requestButtons}}

Catalog excerpts

METRON - 1

SReeR Your future's safe! product catalogue

Open the catalog to page 1
METRON - 2

METRON Aluminum casing Anodized -10 ... +55° C Operating temperature Uscite analogiche e digitali 2 uscite Caps Glass reinforced polypropylene Measurement and automation light curtains... 2

Open the catalog to page 2
METRON - 3

Software configuration Easy to use and extensive parameters choice 7-segment display and LEDs for operating status and light curtain self-diagnosis

Open the catalog to page 3
METRON - 4

OVERVIEW Light curtains for industrial and civil applications where it is necessary to detect, measure, and recognise objects. Depending on the number and position of the beams engaged by an object, Micron and Metron can provide real time information to a PLC or PC in order to: Detect the presence or absence of objects Detect a shape or a profile Measure dimensions TYPICAL APPLICATIONS Measurement of the height of objects in transit on conveyor systems Quality control: verification of presence / absence / position of holes Two-dimensional detection of objects in transit on conveyor systems...

Open the catalog to page 4
METRON - 5

Measurement and identification of cylinders of various sizes Detection of position and profile of pieces in automatic painting systems Loop control Quality control: verification of correct positioning of objects Detection of overall dimensional limits of vehicles for vehicle handling in automatic parking garages Measurement of the width and position of panels or sheets of material in transit on roller units or conveyor belts SPECIAL APPLICATION Automatic warehouse versions Special Micron models with beams spacing: 25, 50, 75 mm The special optics of these light curtains allow detection of...

Open the catalog to page 5
METRON - 6

Ideal for object recognition, quality control, detection of dimensional limits. Ideal for dimensional measurement, detection of object profile and position. Ideal for piece counting and detection of object presence/absence in the controlled field. Four solid state outputs (0 - 24 VDC) with programmable functions. RS 485 serial interface with programmable functions. Two antivalent solid state outputs. Two solid state outputs (0 - 24 VDC) with programmable functions. Solution providing simple on/off information related to the occurrence of the programmed conditions. Solution providing...

Open the catalog to page 6
METRON - 7

£TECHNICAL FEATURES - 2 - models with beams spacing 5 mm Max. range (m) - 6 - models with beam spacing 25, 50, 75 mm - 16 - models with beam spacing 10, 30 mm Measurement time (2.25 ms + 70 js x n beams) x 2 Outputs 4 solid state programmable 0 or 24V (PNP 100 mA 24 VDC) Inputs (on receiver) 1 digital with programmable functions - 0 or 24V Synchronisation between emitter Optical or via cable, selectable and receiver Connector M12 8-pole (emitter) Electrical Connector M16 12-pole (receiver) connections Connector M8 3-pole for RS 232 line programming (receiver) Status display 7-segment...

Open the catalog to page 7
METRON - 8

£ PART NUMBERS Metron A - Beam spacing 5 mm Beam spacing ME ME ME ME ME ME ME ME Metron A - Beam spacing 10 mm Metron A - Beam spacing 25 mm Metron A - Beam spacing 30 mm Metron A - Beam spacing 50 mm Metron A - Beam spacing 75 mm LIGHT CURTAINS FOR MEASUREMENT AND AUTOMATION

Open the catalog to page 8
METRON - 9

£TECHNICAL FEATURES - 2 - models with beams spacing 5 mm Max. range (m) - 6 - models with beam spacing 25, 50, 75 mm - 16 - models with beam spacing 10, 30 mm Measurement time (2.25 ms + 70 js x n beams) x 2 Outputs RS 485 Serial line (up to 8 nodes) 2 solid state programmable 0 or 24V (PNP 100 mA 24 VDC) Inputs (on receiver) 1 digital with programmable functions - 0 or 24V Synchronisation between emitter Optical or via cable, selectable and receiver Connector M12 8-pole (emitter) Electrical Connector M16 12-pole (receiver) connections Connector M8 3-pole for RS 232 line programming...

Open the catalog to page 9
METRON - 10

X PART NUMBERS Metron B - Beam spacing 5 mm Beam spacing ME ME ME ME ME ME ME ME Metron B - Beam spacing 10 mm Metron B - Beam spacing 25 mm Metron B - Beam spacing 30 mm Metron B - Beam spacing 50 mm Metron B - Beam spacing 75 mm LIGHT CURTAINS FOR MEASUREMENT AND AUTOMATION

Open the catalog to page 10
METRON - 11

METRONMETRON CXTECHNICAL FEATURES - 2 - models with beams spacing 5 mm Max. range (m) - 6 - models with beam spacing 25, 50, 75 mm - 16 - models with beam spacing 10, 30 mm Measurement time (2.25 ms + 70 ps x n beams) x 2 Outputs 2 solid state 0 or 24V antivalent (PNP 100 mA 24 VDC) Inputs (on receiver) 1 digital with programmable functions - 0 or 24V Synchronisation between emitter Optical or via cable, selectable and receiver Electrical connections Connector M12 5-pole (emitter and receiver) Status display 7-segment display and LEDs for operating status and light curtain self-diagnosis...

Open the catalog to page 11
METRON - 12

X PART NUMBERS Metron C - Beam spacing 5 mm Beam spacing ME ME ME ME ME ME ME ME Metron C - Beam spacing 10 mm LIGHT CURTAINS FOR MEASUREMENT AND AUTOMATION

Open the catalog to page 12
METRON - 13

METRON CONFIGURATION SOFTWARE Software for PC, with graphic user interface, is supplied with each light curtain (Metron models A and B only). Metron models A and B are provided with an M8 3-pole connector for parameter configuration and monitoring of the light curtain, to be connected to a PC using the CSL 3 cable. ”MetroConf” CHARACTERISTICS Possibility for on-line display on PC screen during operation: (via RS 232) Status of each individual beam and solid state outputs Configurable parameters Operating logic (conditions for output activation) Parameters of the RS 485 serial line...

Open the catalog to page 13
METRON - 14

MECHANICAL DATA Model ME B = (number of beams -1) x beam spacing (with cable synchronisation) B = (number of beams -2) x beam spacing (with optical synchronisation)* 85 (for 10, 30 models) - 93 (for 25, 50, 75 models) Complete set of 4 LS type brackets included in the package B = (number of beams -1) x beam spacing (with cable synchronisation) B (controlled height) B = (number of beams -2) x beam spacing (with optical synchronisation)* C (1st beam position) 85 (for 10 - 30 models) - 93 (for 25-50-75 models) Mounting Complete set of 6 LS type brackets included in the package * In the case of...

Open the catalog to page 14
METRON - 15

FIELD BUS INTERFACES MI - Bs FIELD BUS INTERFACES FOR MICRON Expansion unit for connect Micron light curtain to the most common industrial Field-bus systems for diagnostics and data communication. APPLICATION EXAMPLE In all applications where it is required a communication between the Micron light curtains and PLC control. TECHNICAL FEATURES Ports RS 485 serial ports for I/O BUS expansion USB port for configuration Operating temperature (°C) -10 ... +55 °C Storage temperature (°C) Protection rating ■■ MI - BP - Profibus DP ■■ MI - BD - DeviceNET ■■ MI - BC - CANopen ■■ MI - BEC - EtherCAT...

Open the catalog to page 15

All REER catalogs and technical brochures

  1. EOS

    56 Pages

  2. PI-Safe

    7 Pages

  3. EOS4

    7 Pages

  4. Safety sensors

    52 Pages

  5. SAFELOCK

    3 Pages

  6. Safety Guide

    76 Pages