TECHNICAL DATA SHEET No. 43Reece Safety Products Ltd Unit B9, Lowfields Close, Lowfields Business Park, Elland, West Yorkshire HX5 9DX Tel: 01422 310456 Fax: 01422 311070 Email [email protected] www.reecesafety.co.uk Product Information and Assembly Instructions - Starter Circuit Breaker Kit SCBKIT 3" The CB12 can be used to lock breakers which have no locking facilities. 1 Place circuit breaker in the OFF position (figure 1) 2 Place the CB12 over the circuit breaker toggle as shown (figure 2). 3 Using a small screwdriver, tighten the internal grub screw securing the CB12 onto the toggle (figure 3). 4 Place a lockout padlock through the hole as shown (figure 4). 5 Verify that the circuit breaker toggle is securely fastened and cannot be switched on (figure 5). Locates prongs CB05 Push button operated, the model CB05 fits most popular breakers up to 60 Amp. Will also fit multi-pole breakers. 1 Push the button to release the prongs 2 Hold in position and place the two prongs into the two locating holes either side of the circuit breaker switch. 3 Lock in place using a padlock Remember, the breaker must be in the “off’ position before installing CB06 Push Button operated, the model CB06 fits most popular breakers up to 60 Amp. Will also fit multi-pole breakers. 1 2 breaker switch. 3 Lock in place using a padlock Remember, the breaker must be in the “off1 position before installing CB07 Push button operated, the model CB07 fits most popular breakers up to 60 Amp. Will also fit multi-pole breakers. 1 Push the button to release the prongs 2 Hold in position and place the two prongs into the two locating holes either side of the circuit breaker switch. 3 Lock in place using a padlock Remember, the breaker must be in the “off' position before installing. CB08 Adjustable thumb wheel operation, model CB08 fits larger or multi-pole circuit breakers connected with a cross bar. No holes in the breakers are required. 1 2 as required. 3 Remember, the breaker must be in the “off” position before installing. © Reece Safety Products Ltd

 Open the catalog to page 1

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.