1. Catalogs
  2. Reece Safety Products
  3. New SCBKIT Starter MCB Kit

New SCBKIT Starter MCB Kit

New SCBKIT Starter MCB Kit

Product catalog summary
Product Information and Assembly Instructions - Starter Circuit Breaker Kit SCBKIT
Technical Data Sheet No. 43
Overview: The document provides assembly instructions for the Starter Circuit Breaker Kit SCBKIT, specifically focusing on the CB12 component used to lock circuit breakers without built-in locking facilities.
Assembly Instructions:
  • Step 1: Ensure the circuit breaker is in the OFF position.
  • Step 2: Position the CB12 over the circuit breaker toggle.
  • Step 3: Use a small screwdriver to tighten the internal grub screw, securing the CB12 onto the toggle.
  • Step 4: Insert a lockout padlock through the designated hole.
  • Step 5: Confirm that the circuit breaker toggle is securely fastened and cannot be switched on.
Additional Components: The document references other components (CB05, CB06, CB07, CB08) with similar instructions, emphasizing the importance of securing the circuit breaker toggle.
Contact Information: Reece Safety Products Ltd, Unit B9, Lowfields Close, Lowfields Business Park, Elland, West Yorkshire HX5 9DX. Tel: 01422 310456, Fax: 01422 311070, Email: [email protected], Website: www.reecesafety.co.uk
See more

Catalog excerpts

New SCBKIT Starter MCB Kit-1

TECHNICAL DATA SHEET No. 43Reece Safety Products Ltd Unit B9, Lowfields Close, Lowfields Business Park, Elland, West Yorkshire HX5 9DX Tel: 01422 310456 Fax: 01422 311070 Email [email protected] www.reecesafety.co.uk Product Information and Assembly Instructions - Starter Circuit Breaker Kit SCBKIT 3" The CB12 can be used to lock breakers which have no locking facilities. 1 Place circuit breaker in the OFF position (figure 1) 2 Place the CB12 over the circuit breaker toggle as shown (figure 2). 3 Using a small screwdriver, tighten the internal grub screw securing the CB12 onto the toggle (figure 3). 4 Place a lockout padlock through the hole as shown (figure 4). 5 Verify that the circuit breaker toggle is securely fastened and cannot be switched on (figure 5). Locates prongs CB05 Push button operated, the model CB05 fits most popular breakers up to 60 Amp. Will also fit multi-pole breakers. 1 Push the button to release the prongs 2 Hold in position and place the two prongs into the two locating holes either side of the circuit breaker switch. 3 Lock in place using a padlock Remember, the breaker must be in the “off’ position before installing CB06 Push Button operated, the model CB06 fits most popular breakers up to 60 Amp. Will also fit multi-pole breakers. 1 2 breaker switch. 3 Lock in place using a padlock Remember, the breaker must be in the “off1 position before installing CB07 Push button operated, the model CB07 fits most popular breakers up to 60 Amp. Will also fit multi-pole breakers. 1 Push the button to release the prongs 2 Hold in position and place the two prongs into the two locating holes either side of the circuit breaker switch. 3 Lock in place using a padlock Remember, the breaker must be in the “off' position before installing. CB08 Adjustable thumb wheel operation, model CB08 fits larger or multi-pole circuit breakers connected with a cross bar. No holes in the breakers are required. 1 2 as required. 3 Remember, the breaker must be in the “off” position before installing. © Reece Safety Products Ltd