Catalog excerpts
Reece Safety Products Ltd Premier House, Manchester Road, Mossley, Lancashire OL5 9AA Tel: 01457 831133 Fax: 01457 831144 Email: sales@reecesafety.co.uk www.reecesafety.co.uk Product information and assembly instructions - Subject Circuit Breaker Lockouts CB01 to CB04 Technical Data Sheet No: 9 Date: January 2004 © Reece Safety Products Ltd CB01 Our single pole breaker lockout requires a single switch with a recess hole in it. 1 To install, simply open the lock by sliding the base of the lock backwards. 2 Place over the switch, making sure that the small pole inside the lockout device is now inserted into the hole of the switch. Close the lockout by pushing the base forward after ensuring that the holes are aligned. 3 You are now ready to install your padlock. This model will accommodate breakers upto 12.5mm (1/2”) in width. Remember, the breaker must be in the “off” position before installing. CB02 Our double pole breaker lockout requires that there be two switches connected together with a cross bar. 1 to install, place over the switches with the slotted side of the lockout covering the switches. 2 Pull the slide bar out to attach padlock. This model will accommodate breakers with an overall width of 45mm (1.3/4”). Remember, the breaker must be in the “off” position before installing. CB03 This model is our single breaker lockout for circuit breakers that do not have a recess hole. 1 To install, the breaker must be in the “off” position. Place the breaker lockout over the switch. 2 Insert your screwdriver (star type) into the hole, tighten the screws well. 3 Insert your lock or tag and close. Make sure everything is tight. 4 Lock in place using a padlock This model will accommodate circuit breakers with an overall width of 12.mm (1/2”). Remember, the breaker must be in the “off” position before installing CB04 Our double pole breaker lockout requires that there be two switches connected together with a cross bar. 1 Pull the slider bar and place between the breaker lockout over the breakers. 2 Push back the slider bar and put your padlock over the breakers. This model will accommodate double or triple breakers. Remember, the breaker must be in the “off” position before installing CB01 CB02 CB03 CB04
Open the catalog to page 1All Reece Safety Products catalogs and technical brochures
-
Power Protection Seal
2 Pages
-
60kV Rescue Hook
1 Pages
-
ELE09 Switchboard Matting
4 Pages
-
CB13 CB14 S2390 S2391 CB12
1 Pages
-
New SCBKIT Starter MCB Kit
1 Pages
-
Lockable plug covers
1 Pages
-
Plug Block
1 Pages
-
Full 2015/16 Catalogue
100 Pages
-
R496B Light Switch Lockout
1 Pages
-
Electrical Safety Boots
1 Pages
-
Electrical Safety Gloves
1 Pages
-
RSPL1 Plug Lockout
1 Pages
-
Safety Tag Management System
1 Pages
-
ECBKIT MCB Lockout Kit
2 Pages
-
Pneumatic Lockouts
1 Pages
-
Plug Lockouts
1 Pages
-
BS18 Cable Lockout
1 Pages
-
CB15 Breaker Blocker Kit
1 Pages
-
Fuse Lock / Blockouts
1 Pages
-
IEC 60320 Lockout
1 Pages
-
CB16 / CB16A MCB Lockouts
1 Pages
-
CB12 to CB14 MCB Lockouts
1 Pages
-
LP550 Plug Lockouts
1 Pages
-
CB09 to CB11 MCB Lockouts
1 Pages
-
CB05 to CB08 MCB Lockouts
1 Pages
-
BS04 Butterfly Valve Lockout
1 Pages
-
V-Safe Gate Valve Lockouts
1 Pages
-
Power Protection Seal
2 Pages