Power Rider 25A
6Pages

{{requestButtons}}

Catalog excerpts

Power Rider 25A - 1

Power Rider – 25A Datasheet Power Rider 25– Protect, manage and maintain smart, electronic Circuit breaker and EPD building block Catalog number (P/N) - RD000085 Circuit breaker, relay and contactor in the same product 3 levels of protection: o Software – I2t, Over Current, Over Voltage, Over Temperature. o Hardware – 1μ second cutoff of over current o Mechanical Fuse Solid state-based technology Cascade option. Configurable – over 20 parameters flexible configuration. Building block for power management Input Voltage, Load (Output) Voltage, Current measurement and Temperature measurement. Supports high level of Maintenance -log of events, graphs, conditioned alerts Discrete I/O: 1-Digital Input, 1- Digital Output (Open Collector). Operational switch with smart background light. Indication Function of smart switch: Channel current consumption, Channel status, Fail indicators). Shut Down state. Page 1 of 6 Redler Technologies, Office : Ha’ Gavish 5, Kfar Saba Israel web: www.redler.c

Open the catalog to page 1
Power Rider 25A - 2

Power Rider 25A configuration # Table 1 Configuration Parameters Table Redler Technologies, Office : Ha’ Gavish 5, Kfar Saba Israel web: www.redler.co.il Tel: 972-9-7672980. Fax:972-9-8652381

Open the catalog to page 2
Power Rider 25A - 3

Mechanical dimensions Figure 1 Mechanical Dimension Redler Technologies, Office : Ha’ Gavish 5, Kfar Saba Israel web: www.redler.co.il Tel: 972-9-7672980. Fax:972-9-8652

Open the catalog to page 3
Power Rider 25A - 4

User Interface Description Figure 2 User Interface Connection Side Figure 3 User Interface Control Side Table 2 User Interface Table Redler Technologies, Office : Ha’ Gavish 5, Kfar Saba Israel web: www.redler.co.il Tel: 972-9-7672980. Fax:972-9-8652381

Open the catalog to page 4
Power Rider 25A - 5

Table 3 Control Connector Signal description Power Supply Parameter Table 4 Electrical interface 1 General Purpose Interface Parameter Table 5 Electrical interface 2 Communication Parameter Table 6 communication interfaces Temperature Parameter Redler Technologies, Office : Ha’ Gavish 5, Kfar Saba Israel web: www.redler.co.il Tel: 972-9-7672980. Fax:972-9-8652381

Open the catalog to page 5
Power Rider 25A - 6

Standards: MIL-STD 461E Bonding resistance CE102, conducted emission measurements CS101, conducted susceptibility to electromagnetic interference induced onto power leads CS114, conducted susceptibility, bulk cable injection CS115, conducted susceptibility, bulk cable injection, impulse excitation CS116, conducted susceptibility to damped sinusoidal transients RE101, magnetic field radiated emission measurements RS103, radiated susceptibility to electric field RE102, electric field radiated emission measurements CE101, conducted emission measurements on power leads RS101, radiated...