Catalog excerpts
Power Rider – 25A Datasheet Power Rider 25– Protect, manage and maintain smart, electronic Circuit breaker and EPD building block Catalog number (P/N) - RD000085 Circuit breaker, relay and contactor in the same product 3 levels of protection: o Software – I2t, Over Current, Over Voltage, Over Temperature. o Hardware – 1μ second cutoff of over current o Mechanical Fuse Solid state-based technology Cascade option. Configurable – over 20 parameters flexible configuration. Building block for power management Input Voltage, Load (Output) Voltage, Current measurement and Temperature measurement. Supports high level of Maintenance -log of events, graphs, conditioned alerts Discrete I/O: 1-Digital Input, 1- Digital Output (Open Collector). Operational switch with smart background light. Indication Function of smart switch: Channel current consumption, Channel status, Fail indicators). Shut Down state. Page 1 of 6 Redler Technologies, Office : Ha’ Gavish 5, Kfar Saba Israel web: www.redler.c
Open the catalog to page 1Power Rider 25A configuration # Table 1 Configuration Parameters Table Redler Technologies, Office : Ha’ Gavish 5, Kfar Saba Israel web: www.redler.co.il Tel: 972-9-7672980. Fax:972-9-8652381
Open the catalog to page 2Mechanical dimensions Figure 1 Mechanical Dimension Redler Technologies, Office : Ha’ Gavish 5, Kfar Saba Israel web: www.redler.co.il Tel: 972-9-7672980. Fax:972-9-8652
Open the catalog to page 3User Interface Description Figure 2 User Interface Connection Side Figure 3 User Interface Control Side Table 2 User Interface Table Redler Technologies, Office : Ha’ Gavish 5, Kfar Saba Israel web: www.redler.co.il Tel: 972-9-7672980. Fax:972-9-8652381
Open the catalog to page 4Table 3 Control Connector Signal description Power Supply Parameter Table 4 Electrical interface 1 General Purpose Interface Parameter Table 5 Electrical interface 2 Communication Parameter Table 6 communication interfaces Temperature Parameter Redler Technologies, Office : Ha’ Gavish 5, Kfar Saba Israel web: www.redler.co.il Tel: 972-9-7672980. Fax:972-9-8652381
Open the catalog to page 5Standards: MIL-STD 461E Bonding resistance CE102, conducted emission measurements CS101, conducted susceptibility to electromagnetic interference induced onto power leads CS114, conducted susceptibility, bulk cable injection CS115, conducted susceptibility, bulk cable injection, impulse excitation CS116, conducted susceptibility to damped sinusoidal transients RE101, magnetic field radiated emission measurements RS103, radiated susceptibility to electric field RE102, electric field radiated emission measurements CE101, conducted emission measurements on power leads RS101, radiated...
Open the catalog to page 6All Redler technologies catalogs and technical brochures
-
Electronic Circuit Breaker
2 Pages
-
Rayion-DCHP
4 Pages
-
Rayon-EV
2 Pages
-
Rayon Critical Power
4 Pages
-
Rayon High Power
2 Pages
-
Slim Rayon
2 Pages
-
Rayion-MP
4 Pages
-
Power Rider 80A and 150A
2 Pages
-
Rayon 250A
3 Pages
-
Rayon 40A and 70A
2 Pages
-
Rayon Single board 25A
6 Pages
-
Micro Rayon 15A
2 Pages