DATASHEET Power Rider 25A Catalog number P/N: RD000085 Product rev.: 1.4 Document revision table: First release version Updated Mechanical and Electrical ICD Redler Technologies Ltd. ● Atir Yeda St. 15 ● Kfar Saba Israel 4442211 www.redler.co.il ● Tel: +972 9-7672980 ● Fax: +972 9-8652381
Open the catalog to page 1Power Rider 25A – Protect, Manage and Maintain Smart, electronic circuit breaker and EPD building block. Functionality: • Circuit breaker (fuse), relay, and contactor Three levels of protection: ∙ Software – I²t, over-current, over-voltage, over-temperature ∙ Hardware – 1μ second over-current cutoff ∙ Thermal fuse Solid-state based technology Circuit breaker support network Configurable – over 20 flexible configuration parameters Building block for ‘Power Distribution Unit’ Measurement of input voltage, output voltage, load current and temperature Advanced reporting and easy maintenance –...
Open the catalog to page 2Power Rider 25A Configuration: Over Current Parameter controlled by user Parameter controlled by user Voltage Error Parameter controlled by user (low voltage, high voltage) Temperature Error Parameter controlled by user (low temperature, high temperature) Trip Event (Software) Trip event software protection. Trip Event (Hardware) Trip event hardware protection (hard short). Not controlled by user. Trip Recovery Channel Logic Control Digital Output Logic Control Channel Control Timeout. Parameter controlled by user Digital Output control Timeout. Parameter controlled by user Status Report...
Open the catalog to page 3Electrical ICD Power Signal description: Signal Type Signal Name - Signal Description Power Input + (+Vin) Power Output (Load) Power Input return (-Vin) Table 2 Power Signal Table Control Connector Signal description: Signal Type Signal Name - Signal Description Signal Ground Open drain 0.25 Ampere output Table 3 Control Connector Table Redler Technologies Ltd. ● Atir Yeda St. 15 ● Kfar Saba Israel 4442211 www.redler.co.il ● Tel: +972 9-7672980 ● Fax: +972 9-8652381
Open the catalog to page 4Electrical Interface: Power Supply Parameter Power Input Voltage (Recommended Ratings) Power Input Voltage (Absolute Maximum Ratings) Power consumption (operating) Total channel Current (see Figure 2) Nominal channel resistance @ 25 deg General Purpose Interface Parameter Digital Output Voltage Digital Output Current Digital Input Current Digital Input Voltage Remarks open collector open collector active low active high Temperature Parameter Operating Temperature (*see Figure 2) Storage Temperature Redler Technologies Ltd. ● Atir Yeda St. 15 ● Kfar Saba Israel 4442211 www.redler.co.il ●...
Open the catalog to page 5Physical connections for Digital input: Dinxx – DIN (J1/pin 2) GND_ISO1 – Ground (J1/pin1) Active High connection Dinxx – DIN (J1/pin 2) GND_ISO1 – Ground (J1/pin1) Physical connections for Digital output: Protected Output (D-out) - J1/5 PWR_GND – Power GND Redler Technologies Ltd. ● Atir Yeda St. 15 ● Kfar Saba Israel 4442211 www.redler.co.il ● Tel: +972 9-7672980 ● Fax: +972 9-865238
Open the catalog to page 6Mechanical ICD User Interface Description Figure 2 User Interface Connection Side Parallel Pin Surface Mount Nut Control Switch Figure 1 User Interface Control Side Figure 3 User Interface Connection Redler Technologies Ltd. ● Atir Yeda St. 15 ● Kfar Saba Israel 4442211 www.redler.co.il ● Tel: +972 9-7672980 ● Fax: +972 9-8652381
Open the catalog to page 7IN/OUT Phillips Pan Head Machine Screw, MS51957-26, 6-32x1/4 (for IN/OUT) ,see figure 3. GND Phillips Pan Head Machine Screw, MS5195713, 4-40x1/4 (for GND) ,see figure 3. IN/OUT Split Helical Lock Washer, MS35338-136, #6 (for IN/OUT) ,see figure 3. GND Split Helical Lock Washer, MS35338-135, #4 (for GND) ,see figure 3. GND Ring cable lug, Ring Tongue 32441, #4, 14-16 AWG, or equivalent (for GND) ,see figure 3. IN/OUT Ring cable lug, Ring Tongue 34852-1, #6, 10-12 AWG, or equivalent (for IN/OUT),see figure 3. J1 Communication and digital interface. Control Connector. See Figure2/Table 3...
Open the catalog to page 8Mechanical dimensions: (in mm unless otherwise noted) Figure 4 Mechanical Dimension Redler Technologies Ltd. ● Atir Yeda St. 15 ● Kfar Saba Israel 4442211 www.redler.co.il ● Tel: +972 9-7672980 ● Fax: +972 9-8652381
Open the catalog to page 9Derating Table: Current [A] No Cooling Plate With Cooling Plate Figure 5 Power Rider 25A Derating Table Cooling Plate dimension: 190x105x5 mm Redler Technologies Ltd. ● Atir Yeda St. 15 ● Kfar Saba Israel 4442211 www.redler.co.il ● Tel: +972 9-7672980 ● Fax: +972 9-8652381
Open the catalog to page 10Accessories: Harnesses CANBUS Kvaser Control Harness RD000167 Figure 6 CANBUS Kvaser Control Harness RD000167 Redler Technologies Ltd. ● Atir Yeda St. 15 ● Kfar Saba Israel 4442211 www.redler.co.il ● Tel: +972 9-7672980 ● Fax: +972 9-8652381
Open the catalog to page 11CANBUS CANalyst-II Control Harness RD000263 Figure 7 CANBUS CANalyst-II Control Harness RD000263 * One of two control harnesses RD000167 or RD000263 must be used according to the type of communication adapter. Redler Technologies Ltd. ● Atir Yeda St. 15 ● Kfar Saba Israel 4442211 www.redler.co.il ● Tel: +972 9-7672980 ● Fax: +972 9-8652381
Open the catalog to page 12Power IN/OUT Harness RD000168 Figure 8 Power IN/OUT Harness RD000168 Redler Technologies Ltd. ● Atir Yeda St. 15 ● Kfar Saba Israel 4442211 www.redler.co.il ● Tel: +972 9-7672980 ● Fax: +972 9-8652381
Open the catalog to page 13Figure 9 Power GND Harness RD000169 Redler Technologies Ltd. ● Atir Yeda St. 15 ● Kfar Saba Israel 4442211 www.redler.co.il ● Tel: +972 9-7672980 ● Fax: +972 9-8652381
Open the catalog to page 14Description Ring cable lug, Ring Tongue 32441, #4, 14-16 AWG, or equivalent (for GND) Ring cable lug, Ring Tongue 34852-1, #6, 1012 AWG, or equivalent (for IN/OUT) CANBUS CANalyst-II Control Harness CANBUS CANalyst-II USB adapter Power Rider Studio CANBUS adapters: Kvaser Leaf Light HS v2 CANBUS to USB adapter RRAUX000012 CANalyst-II CANBUS to USB adapter RRAUX000013 Redler Technologies Ltd. ● Atir Yeda St. 15 ● Kfar Saba Israel 4442211 www.redler.co.il ● Tel: +972 9-7672980 ● Fax: +972 9-8652381
Open the catalog to page 15Power Rider Studio (GUI) RRAUX000014: *Please refer to the Power Rider Studio software User Manual for more information Power Rider LabVIEW Demo package: https://github.com/RedlerTechnologies/Power-Rider-LW-Demo-WrapperPower Rider Visual Studio example package: https://github.com/RedlerTechnologies/PowerDLLWrapper_Example Redler Technologies Ltd. ● Atir Yeda St. 15 ● Kfar Saba Israel 4442211 www.redler.co.il ● Tel: +972 9-7672980 ● Fax: +972 9-8652381
Open the catalog to page 16All Redler Technologies LTD catalogs and technical brochures
-
Power Rider 12CH
6 Pages
-
RAYON 135
19 Pages
-
Power Rider HV 25A
15 Pages
-
Power Rider 150A
12 Pages
-
Electronic Circuit Breaker
2 Pages
-
Rayion-DCHP
4 Pages
-
Rayon-EV
2 Pages
-
Rayon Critical Power
4 Pages
-
Rayon High Power
2 Pages
-
Slim Rayon
2 Pages
-
Rayion-MP
4 Pages
-
Power Rider 80A and 150A
2 Pages
-
Rayon 250A
3 Pages
-
Rayon 40A and 70A
2 Pages
-
Rayon Single board 25A
6 Pages
-
Micro Rayon 15A
2 Pages