PAXLCR
12Pages

{{requestButtons}}

Catalog excerpts

PAXLCR - 1

1 3.60 (91.4) (96.5) 3.80 1.95 (49.5) (2.5) .10 (104.1) 4.10 (44.5) 1.75 PAR 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 SEL RST SP1 SP2 AB GENERAL DESCRIPTION The PAXLCR is a versatile meter that provides a single or dual counter with rate indication, scaling and dual relay outputs. The 6-digit display has 0.56" high digits with adjustable display intensity. The display can be toggled manually or automatically between the selected counter and rate values. The meter has two signal inputs and a choice of eight different count modes. These include bi-directional, quadrature and anti-coincidence counting, as well as a dual counter mode. When programmed as a Dual Counter, each counter has separate scaling and decimal point selection. Rate indication is available in all count modes. The Rate Indicator has separate scaling and decimal point selection, along with programmable display update times. In addition to the signal inputs, the User Input can be programmed to perform a variety of meter control functions. Two setpoint outputs are provided, each with a Form C relay. The outputs can activate based on either counter or rate setpoint values. An internal batch counter can be used to count setpoint output activations. The PAXLCR can be powered from a wide range of AC or DC voltages. The meter has been specifically designed for harsh industrial environments. With a NEMA 4X/IP65 sealed bezel and extensive testing to meet CE requirements, the meter provides a tough yet reliable application solution. MODEL NO. DESCRIPTION PART NUMBER PAXLCR Dual Counter & Rate Meter with Dual Relay Output PAXLCR00 PAXLCRU UL Listed Dual Counter & Rate Meter with Dual Relay Output PAXLCRU0 SAFETY SUMMARY All safety regulations, local codes and instructions that appear in this and corresponding literature, or on equipment, must be observed to ensure personal safety and to prevent damage to either the instrument or equipment connected to it. If equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. Do not use this meter to directly command motors, valves, or other actuators not equipped with safeguards. To do so can be potentially harmful to persons or equipment in the event of a fault to the meter SPECIFICATIONS 1. DISPLAY: 6 digit, 0.56" (14.2 mm) intensity adjustable Red LED 2. POWER REQUIREMENTS: AC POWER: 50 to 250 VAC 50/60 Hz, 12 VA Isolation: 2300 Vrms for 1 min. to all inputs and outputs DC POWER: 21.6 to 250 VDC, 6 W DC Out: +24 VDC @ 100 mA if input voltage is greater than 50 VAC/VDC +24 VDC @ 50 mA if input voltage is less than 50 VDC 3. COUNTER DISPLAYS: Counter A: 6-digits, enabled in all count modes Display Designator: “A” to the left side of the display Display Range: -99999 to 999999 Counter B: 6-digits, enabled in Dual Count mode or Batch Counter Display Designator: “B” to the left side of the display Display Range: 0 to 999999 (positive count only) Overflow Indication: Display “ƒ¿ƒ¼ƒ¿ƒ¼” alternates with overflowed count value Maximum Count Rates: 50% duty cycle, count mode dependent. With setpoints disabled: 25 KHz, all modes except Quadrature x4 (23 KHz). With setpoint(s) enabled: 20 KHz, all modes except Dual Counter (14 KHz), Quadrature x2 (13 KHz) and Quadrature x4 (12 KHz). ƒÜ 6 DIGIT, 0.56" HIGH RED LED DISPLAY ƒÜ PROGRAMMABLE SCALING FOR COUNT AND RATE ƒÜ BI-DIRECTIONAL COUNTING, UP/DOWN CONTROL ƒÜ QUADRATURE SENSING (UP TO 4 TIMES RESOLUTION) ƒÜ BUILT-IN BATCH COUNTING CAPABILITY ƒÜ PROGRAMMABLE USER INPUT ƒÜ DUAL 5 AMP FORM C RELAYS ƒÜ UNIVERSALLY POWERED ƒÜ NEMA 4X/IP65 SEALED FRONT BEZEL MODEL PAXLCR - PAX LITE DUAL COUNTER AND RATE METER DIMENSIONS In inches (mm) Bulletin No. PAXLCR- B Drawing No. LP0749 Released 04/09 Tel +1 (717) 767-6511 Fax +1 (717) 764-0839 www.redlion.net CAUTION: Risk of Danger. Read complete instructions prior to installation and operation of the unit. CAUTION: Risk of electric shock. ORDERING INFORMATION Note: Recommended minimum clearance (behind the panel) for mounting clip installation is 2.1" (53.4) H x 5.0" (127) W. C US LISTED UL R IND. CONT. EQ. 51EB For Model No. PAXLCRU0 Only

Open the catalog to page 1
PAXLCR - 2

2 4. RATE DISPLAY: 6-digits, may be enabled or disabled in any count mode Display Range: 0 to 999999 Over Range Display: “ƒ¿ƒ¼ƒ¿ƒ¼” Maximum Frequency: 25 KHz Minimum Frequency: 0.01 Hz Accuracy: ±0.01% 5. COUNT/RATE SIGNAL INPUTS (INPUT A and INPUT B): See Section 2.0 Setting the DIP Switches for complete Input specifications. DIP switch selectable inputs accept pulses from a variety of sources. Both inputs allow selectable active low or active high logic, and selectable input filtering for low frequency signals or switch contact debounce. Input A: Logic level or magnetic pickup signals....

Open the catalog to page 2
PAXLCR - 3

3 3.0 WIRING THE METER WIRING OVERVIEW Electrical connections are made via screw-clamp terminals located on the back of the meter. All conductors should conform to the meter’s voltage and current ratings. All cabling should conform to appropriate standards of good installation, local codes and regulations. It is recommended that the power supplied to the meter (DC or AC) be protected by a fuse or circuit breaker. When wiring the meter, compare the numbers embossed on the back of the meter case against those shown in wiring drawings for proper wire position. Strip the wire, leaving...

Open the catalog to page 3
PAXLCR - 4

4 3.3 USER INPUT WIRING CAUTION: DC common (Terminal 4) is NOT isolated from Input common (Terminal 7) or User common (Terminal 9). In order to preserve the safety of the meter application, DC common must be suitably isolated from hazardous live earth referenced voltage; or Input common and User common must be at protective earth ground potential. If not, hazardous voltage may be present at the Signal or User Inputs, and Input or User common terminals. Appropriate considerations must then be given to the potential of the Input or User common with respect to earth ground. Terminal 8: User...

Open the catalog to page 4

All Red Lion Controls catalogs and technical brochures

  1. NT24k-16M12

    4 Pages

  2. RAM-6000 3G

    3 Pages

  3. HMI Brochure

    18 Pages

  4. N-View ® 2

    2 Pages

  5. 708M12-HV

    3 Pages

  6. ET-8MG-OEM-F

    2 Pages

  7. Protocol

    2 Pages

  8. RAM 9000

    3 Pages

  9. RAM 6000 LTE

    3 Pages

Archived catalogs

  1. LD

    16 Pages

  2. CUB4L

    4 Pages

  3. GEMINI 52

    8 Pages

  4. CUB5

    16 Pages

  5. EPAX/MPAX

    8 Pages

  6. PAXI

    32 Pages

  7. LPAX/MPAX

    4 Pages

  8. LEGEND

    8 Pages

  9. GEMINI 1 & 2

    8 Pages

  10. C48C

    6 Pages