1 ƒÜ COUNT, DUAL COUNTER, RATE AND SLAVE DISPLAY ƒÜ 0.56" RED SUNLIGHT READABLE DISPLAY ƒÜ VARIABLE INTENSITY DISPLAY ƒÜ 10 POINT SCALING FOR NON-LINEAR PROCESSES (PAXI) ƒÜ FOUR SETPOINT ALARM OUTPUTS (W/Option Card) ƒÜ RETRANSMITTED ANALOG OUTPUT (W/Option Card) (PAXI) ƒÜ COMMUNICATION AND BUS CAPABILITIES (W/Option Card) (PAXI) ƒÜ BUS CAPABILITIES; DEVICENET, MODBUS, AND PROFIBUS-DP ƒÜ CRIMSON PROGRAMMING SOFTWARE (PAXI) ƒÜ ETHERNET(W/ External Gateway) (PAXI) ƒÜ NEMA 4X/IP65 SEALED FRONT BEZEL GENERAL DESCRIPTION The PAX Digital Input Panel Meters offer many features and performance capabilities to suit a wide range of industrial applications. Available in three different models, PAXC Counter/Dual Counter, PAXR Rate Meter and the PAXI which offers both counting and rate in the same package. Refer to pages 4 - 5 for the details on the specific models. The PAXC and PAXR offer only the Setpoint Option, while the PAXI is the fully featured version offering all the capabilities as outlined in this bulletin as well as a slave display feature. The optional plug-in output cards allow the opportunity to configure the meter for present applications, while providing easy upgrades for future needs. The meters employ a bright 0.56" LED display. The meters are available with a red sunlight readable or standard green LED display. The intensity of the display can be adjusted from dark room applications up to sunlight readable, making it ideal for viewing in bright light applications. The meters accept digital inputs from a variety of sources including switch contacts, outputs from CMOS or TTL circuits, magnetic pickups and all standard RLC sensors. The meter can accept directional, uni-directional or Quadrature signals simultaneously. The maximum input signal varies up to 34 KHz depending on the count mode and function configurations programmed. Each input signal can be independently scaled to various process values. The Rate Meters provide a MAX and MIN reading memory with programmable capture time. The capture time is used to prevent detection of false max or min readings which may occur during start-up or unusual process events. The meters have four setpoint outputs, implemented on Plug-in option cards. The Plug-in cards provide dual FORM-C relays (5A), quad FORM-A (3A), or either quad sinking or quad sourcing open collector logic outputs. The setpoint alarms can be configured to suit a variety of control and alarm requirements. Communication and Bus Capabilities are also available as option cards for the PAXI only. These include RS232, RS485, Modbus, DeviceNet, and Profibus-DP. Readout values and setpoint alarm values can be controlled through the bus. Additionally, the meters have a feature that allows a remote computer to directly control the outputs of the meter. With an RS232 or RS485 card installed, it is possible to configure the meter using Red Lion’s Crimson software. The configuration data can be saved to a file for later recall. A linear DC output signal is available as an optional Plug-in card for the PAXI only. The card provides either 20 mA or 10 V signals. The output can be scaled independent of the input range and can track any of the counter or rate displays. Once the meters have been initially configured, the parameter list may be locked out from further modification in its entirety or only the setpoint values can be made accessible. The meters have been specifically designed for harsh industrial environments. With NEMA 4X/IP65 sealed bezel and extensive testing of noise effects to CE requirements, the meter provides a tough yet reliable application solution. SAFETY SUMMARY All safety related regulations, local codes and instructions that appear in this literature or on equipment must be observed to ensure personal safety and to prevent damage to either the instrument or equipment connected to it. If equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. Do not use this meter to directly command motors, valves, or other actuators not equipped with safeguards. To do so can be potentially harmful to persons or equipment in the event of a fault to the meter. MODEL PAX - 1/8 DIN DIGITAL INPUT PANEL METERS Bulletin No. PAXICR-G Drawing No. LP0548 Released 10/09 Tel +1 (717) 767-6511 Fax +1 (717) 764-0839 www.redlion.net CAUTION: Risk of Danger. Read complete instructions prior to installation and operation of the unit. CAUTION: Risk of electric shock. 3.80 1.95 .10 4.10 (96.5) (2.5) (49.5) (104.1) 1.75 (44.5) DSP PAR F1 F2 RST A C B SP1 SP2 SP3 SP4 3.60 (91.4) 25 24 23 22 21 20 1 2 3 4 5 6 7 8 9 10 11 15 14 13 19 18 17 12 16 (44.5) 1.75 DIMENSIONS In inches (mm) Note: Recommended minimum clearance (behind the panel) for mounting clip installation is 2.1" (53.4) H x 5" (127) W. C US LISTED UL R 51EB IND. CONT. EQ.
Open the catalog to page 12 Ordering Information . . . . . . . . . . . . . . . . . . . . 2 General Meter Specifications . . . . . . . . . . . . . 3 PAXC Counter . . . . . . . . . . . . . . . . . . . . . . . . . 4 PAXR Rate Meter . . . . . . . . . . . . . . . . . . . . . . 4 PAXI Counter/Rate Meter . . . . . . . . . . . . . . . . 5 Optional Plug-In Output Cards . . . . . . . . . . . . 6 Installing the Meter . . . . . . . . . . . . . . . . . . . . . 7 Setting the Jumper and DIP Switches . . . . . . 7 Installing Plug-In Cards . . . . . . . . . . . . . . . . . . 8 Wiring the Meter . . . . . . . . . . . . . . . . . . . ....
Open the catalog to page 23 GENERAL METER SPECIFICATIONS 1. DISPLAY: 6 digit, 0.56" (14.2 mm) red sunlight readable or standard green LED 2. POWER: AC Versions: AC Power: 85 to 250 VAC, 50/60 Hz, 18 VA Isolation: 2300 Vrms for 1 min. to all inputs and outputs. (300 V working) DC Versions: DC Power: 11 to 36 VDC, 14 W (derate operating temperature to 40° C if operating <15 VDC and three plug-in option cards are installed) AC Power: 24 VAC, ± 10%, 50/60 Hz, 15 VA Isolation: 500 Vrms for 1 min. to all inputs and outputs (50 V working). 3. SENSOR POWER: 12 VDC, ±10%, 100 mA max. Short circuit protected 4. KEYPAD: 3...
Open the catalog to page 3All Red Lion Controls catalogs and technical brochures
-
FlexEdge Water/Wastewater
4 Pages
-
FlexEdge Oil & Gas
12 Pages
-
FlexEdge Brochure
8 Pages
-
Graphite® Expansion Racks
3 Pages
-
Graphite® Core Controller
2 Pages
-
PXU PID Controller
3 Pages
-
PAX® 2C PID Controller
3 Pages
-
E3 I/O™ Modules
3 Pages
-
Graphite® Edge Controller
2 Pages
-
CR1000 and CR3000
4 Pages
-
NT24k-16M12
4 Pages
-
RAM-6000 3G
3 Pages
-
SN-6000 3G Data Sheet
3 Pages
-
NTPS-24-1.3 Power Supply
1 Pages
-
Modular Controller Brochure
8 Pages
-
HMI Brochure
18 Pages
-
Data Station Plus Brochure
8 Pages
-
Protocol Sell Sheet
2 Pages
-
Industrial Automation Guide
13 Pages
-
Visual Management
2 Pages
-
N-View ® 2
2 Pages
-
708M12-HV
3 Pages
-
EB-GT-8ES-1EP
2 Pages
-
ET-8MG-OEM-F
2 Pages
-
ET-8MS-OEM-2-3
3 Pages
-
RTU & I/O Line Card
2 Pages
-
Protocol
2 Pages
-
VersaTRAK MIPM Data Sheet
2 Pages
-
SixTRAK ® IPm ™
1 Pages
-
Graphite ® Core Controller
2 Pages
-
RAM 9000
3 Pages
-
RAM 6000 LTE
3 Pages
-
Automation Guide
24 Pages
-
E3 I/O ™ Modules
3 Pages