Catalog excerpts
1 .. LARGE LED DISPLAY READABLE TO 180 FEET .. VARIOUS DIGITAL INPUT MODULES; COUNT AND RATE INPUT CLOCK/TIMER SERIAL SLAVE .. ALARMS, ANALOG OUTPUT, AND COMMUNICATION .. PROGRAMMABLE USER INPUTS .. UNIVERSAL AC POWERED (85 to 250 VAC) .. PC SOFTWARE FOR METER CONFIGURATION .. NEMA 4X/IP65 GENERAL DESCRIPTION The EPAX Display is a versatile display that can increase productivity by offering the plant floor or production area a large visual display of their current status. Whether your measurement is rate, count, or time, the EPAX can satisfy your requirement. The EPAX displays accept various digital inputs through the use of input modules (MPAX) which allow the unit to adapt to most any application. The MPAX Modules offer the same features as our highly successful PAX Series Panel Meters. Additional plug-in option cards can add alarms, analog output, and communication/bus capabilities, making the EPAX a truly Intelligent Panel Meter. SAFETY SUMMARY All safety regulations, local codes and instructions that appear in this and corresponding literature, or on equipment, must be observed to ensure personal safety and to prevent damage to either the instrument or equipment connected to it. If equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. The protective conductor terminal is bonded to conductive parts of the equipment for safety purposes and must be connected to an external protective earthing system. SPECIFICATIONS Additional specifications, wiring, programming, and information for the individual MPAX models are contained in the corresponding standard PAX literature. This PAX literature is shipped with the ordered MPAX model. 1. DISPLAY: 4" (101 mm) Red LED 6-Digit (EPAX0600): (-99999 to 999999) 2. POWER REQUIREMENTS: AC MPAX Modules: 85 to 250 VAC, 50/60 Hz, 18 VA EPAX Display: 85 to 250 VAC, 50/60 Hz, 10 VA 3. INPUT: Accepts digital input modules, see “Selecting Your Display Components and Option Cards.” 4. ANNUNCIATORS: Display Indication: Three vertical dots on the left side of the unit identify the displays for the following modules: Setpoint Indication: Four vertical dots on the right side of the unit identify the setpoint “ON” condition, with SP 1 being the top position through SP 4 at the bottom. 5. EPAX Programming: The unit is a large display, designed to be remotely mounted. Therefore, the unit does not have a programming keypad. Unit programming should be accomplished by one of the following methods: Rear Terminal Block: External switches can be wired via the terminal block to allow unit programming. A minimum of 3 switches would be required. Optional Programming Remote (EPAXPGM0): This option provides a 10 foot interconnecting cable and programming box. The Programming Remote contains buttons similar to the PAX, allowing easy programming of the EPAX display. Optional Serial Programming: Like all PAX units, you can purchase an RS232 or RS485 Comms Card and program the unit via Windows® based software programs. MODEL EPAX- 6 DIGIT EXTRA LARGE PAX DISPLAY FOR DIGITAL INPUTS DIMENSIONS In inches (mm) CAUTION: Risk of Danger. Read complete instructions prior to installation and operation of the unit. CAUTION: Risk of electric shock. Bulletin No. EPAX6-D Drawing No. LP0539 Released 6/07 Tel +1 (717) 767-6511 Fax +1 (717) 764-0839 www.redlion.net COUNT/RATE CLOCK TOP Display A Timer MIDDLE Display B Count BOTTOM Display C Date C US LISTED UL R IND. CONT. EQ. 51EB
Open the catalog to page 12 WARNING: Disconnect all power to the unit before installing Plug-in cards. Adding Option Cards The PAX and MPAX series meters can be fitted with up to three optional plugin cards. The details for each plug-in card can be reviewed in the specification section of the PAX Bulletin. Only one card from each function type can be installed at one time. The function types include Setpoint Alarms (PAXCDS), Communications (PAXCDC), and Analog Output (PAXCDL). The plug-in cards can be installed initially or at a later date. SETPOINT ALARMS PLUG-IN CARDS (PAXCDS) The PAX and MPAX series has 4...
Open the catalog to page 2CAUTION: The MPAX main circuit board and the option cards contain static sensitive components. Before handling the module or the cards, discharge static charges from your body by touching a grounded bare metal object. Handle the module by the rear plastic cover only, and the option cards by the board edges. Dirt, oil or other contaminants that contact the circuit boards or components can adversely affect circuit operation. WARNING: Exposed line voltage exists on the MPAX main circuit board and the option cards. DO NOT apply power to the module OR load circuits until the module is properly...
Open the catalog to page 34 2.0 INSTALLING THE DISPLAY EPAX DISPLAY INSTALLATION The EPAX display is intended to be mounted into a panel or enclosure. The display is provided with a gasket to provide a water-tight seal. The recommended minimum panel thickness for NEMA 4/IP65 sealing is 0.060" (1.57 mm). For panel mounting, prepare the panel cut-out to the dimensions shown in Figure 3. The supplied template may be used to mark the cut-out and hole locations on the panel. After the panel cut-out has been deburred, slide the panel gasket over the rear of the display and onto the mounting studs. Insert the display into...
Open the catalog to page 45 Once assembled, the EPAX and MPAX have all the same functions and capabilities of our PAX Series Intelligent Panel Meters. Therefore, you will find the appropriate PAX information packed with the MPAX Module. Simply follow the instructions to wire and program the display for your application. Note: Both the EPAX and the MPAX module require power. It is recommended to connect the primary AC power to the EPAX terminal block, then jumper to the MPAX module. EPAX PROGRAMMING The unit is a large display, designed to be remotely mounted. Therefore, the unit does not have a programming keypad....
Open the catalog to page 56 .. LIGHT-WEIGHT ALUMINUM CONSTRUCTION .. COMPLETELY SEALED FOR WASH-DOWN .. MOUNTING CHANNELS FOR VERSATILE INSTALLATION DESCRIPTION The NEMA 4/IP65 Large Display Enclosure is designed to protect the EPAX from dust and hose directed water, when properly installed. This light-weight all aluminum unit utilizes welded seams and neoprene gaskets to meet NEMA 4/IP65 requirements. A textured, polyurethane coating protects against corrosion and is scratch resistant. Figure 1 below shows the overall dimensions of the Enclosure. The Display Enclosure with Mounting Channels weighs 9 pounds (4.1...
Open the catalog to page 6All Red Lion Controls catalogs and technical brochures
-
FlexEdge Water/Wastewater
4 Pages
-
FlexEdge Oil & Gas
12 Pages
-
FlexEdge Brochure
8 Pages
-
Graphite® Expansion Racks
3 Pages
-
Graphite® Core Controller
2 Pages
-
PXU PID Controller
3 Pages
-
PAX® 2C PID Controller
3 Pages
-
E3 I/O™ Modules
3 Pages
-
Graphite® Edge Controller
2 Pages
-
CR1000 and CR3000
4 Pages
-
NT24k-16M12
4 Pages
-
RAM-6000 3G
3 Pages
-
SN-6000 3G Data Sheet
3 Pages
-
NTPS-24-1.3 Power Supply
1 Pages
-
Modular Controller Brochure
8 Pages
-
HMI Brochure
18 Pages
-
Data Station Plus Brochure
8 Pages
-
Protocol Sell Sheet
2 Pages
-
Industrial Automation Guide
13 Pages
-
Visual Management
2 Pages
-
N-View ® 2
2 Pages
-
708M12-HV
3 Pages
-
EB-GT-8ES-1EP
2 Pages
-
ET-8MG-OEM-F
2 Pages
-
ET-8MS-OEM-2-3
3 Pages
-
RTU & I/O Line Card
2 Pages
-
Protocol
2 Pages
-
VersaTRAK MIPM Data Sheet
2 Pages
-
SixTRAK ® IPm ™
1 Pages
-
Graphite ® Core Controller
2 Pages
-
RAM 9000
3 Pages
-
RAM 6000 LTE
3 Pages
-
Automation Guide
24 Pages
-
E3 I/O ™ Modules
3 Pages