CUB5
16Pages

{{requestButtons}}

Catalog excerpts

CUB5 - 1

1 Ć LCD, REFLECTIVE OR GREEN/RED LED BACKLIGHTING Ć 0.46" (11.7 mm) HIGH DIGITS Ć OPTIONAL SETPOINT OUTPUT CARD Ć OPTIONAL SERIAL COMMUNICATIONS CARD (RS232 or RS485) Ć OPTIONAL USB PROGRAMMING CARD Ć OPERATES FROM 9 TO 28 VDC POWER SOURCE Ć PROGRAMMABLE SCALING FOR COUNT AND RATE Ć BI-DIRECTIONAL COUNTING, UP/DOWN CONTROL Ć QUADRATURE SENSING (UP TO 4 TIMES RESOLUTION) Ć BUILT-IN BATCH COUNTING CAPABILITY Ć DISPLAY COLOR CHANGE CAPABILITY AT SETPOINT OUTPUT Ć NEMA 4X/IP65 SEALED FRONT BEZEL MODEL CUB5 - MINIATURE ELECTRONIC 8-DIGIT DUAL COUNTER AND RATE INDICATOR GENERAL DESCRIPTION The CUB5 provides the user the ultimate in flexibility, from its complete user programming to the optional setpoint control and communication capability. The meter can be programmed as a single or dual counter with rate indication capability. The display can be toggled either manually or automatically between the selected displays. The CUB5 display has 0.46" (11.7 mm) high digits. The LCD is available in two versions, reflective (CUB5R000) and backlight (CUB5B000). The backlight version is user selectable for green or red backlighting with variable display intensity. The counter is programmable for one of eight different count modes, including bi-directional and quadrature. When programmed as a dual counter, each counter has a separate scale factor and decimal points. In the counter/rate indicator mode, each have their own scaling and decimal point read-outs in different engineering units. The internal batch counter can be used to count setpoint output activations. The meter has two separate inputs which provide different functions depending on which operating mode is selected. Input A accepts the signal for the Count and/or Rate displays, while Input B accepts the signal for the Count display or direction control. In the anti-coincidence mode, both inputs are monitored simultaneously so that no counts are lost. The resulting display can be chosen as the sum or difference of the two inputs. The Rate Indicator has programmable low (minimum) and high (maximum) update times to provide optimal display response at any input frequency. There is a programmable user input that can be programmed to perform a variety of functions. The capability of the CUB5 can be easily expanded with the addition of option cards. Setpoint capability is field installable with the addition of the single setpoint relay output card or the dual setpoint solid state output card. Serial communications capability for RS232 or RS485 is added with a serial option card. The CUB5 can be powered from an optional Red Lion Micro-Line/Sensor Power Supply (MLPS), which attaches directly to the back of a CUB5. The MLPS is powered from 85 to 250 VAC and provides up to 400 mA to drive the unit and sensors. COUNTER The CUB5 receives incoming pulses and multiplies them by the Count Scale Factor to obtain the desired reading for the count display. Input A accepts the signal for the count and Input B is used for quadrature, dual counter, anticoincidence counting, or up/down control counting. RATE The rate indicator utilizes the signal at Input A to calculate the rate value using a time interval method (1/tau). The unit counts on the negative edge of the input pulses. After the programmed minimum update time elapses and the next negative edge occurs, the unit calculates the input rate based on the number of edges that occurred during the elapsed time. The input rate is then multiplied by the rate scaling value to calculate the rate display. At slower rates, averaging can be accomplished by programming the rate minimum update time for the desired response. Extensive scaling capabilities allow practically any desired reading at very slow count rates. SAFETY SUMMARY All safety related regulations, local codes and instructions that appear in this literature or on equipment must be observed to ensure personal safety and to prevent damage to either the instrument or equipment connected to it. If equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. Do not use this meter to directly command motors, valves, or other actuators not equipped with safeguards. To do so can be potentially harmful to persons or equipment in the event of a fault to the meter. Bulletin No. CUB5-J Drawing No. LP0584 Released 02/10 Tel +1 (717) 767-6511 Fax +1 (717) 764-0839 www.redlion.net CAUTION: Risk of Danger. Read complete instructions prior to installationand operation of the unit. CAUTION: Risk of electric shock. .13 (3.3) (43.4) 2.95 (74.9) 1.71 SEL .15 (3.8) 1.54 (39.1) RST (68 ) +.025 -.000 -0 +8 1.29 (32.8) 2.68 1.30 -.000 (33 ) 1 2 3 4 -0 +6 +.024 ON ECE 9876543.2 Note: Recommended minimum clearance (behind the panel) for mounting clip installation is 2.15" (54.6) H x 3.00" (76.2) W. C US LISTED UL R 51EB IND. CONT. EQ. DIMENSIONS In inches (mm)

Open the catalog to page 1
CUB5 - 2

1. DISPLAY: 8 digit LCD 0.46" (11.7 mm) high digits CUB5R000: Reflective LCD with full viewing angle CUB5B000: Transmissive LCD with selectable red or green LED backlight, viewing angle optimized. Display color change capability with output state when using an output module. 2. POWER: Input voltage range is +9 to +28 VDC with short circuit and input polarity protection. Must use an RLC model MLPS or an NEC Class 2 or Limited Power Source (LPS) rated power supply. MODEL NO. DISPLAY COLOR INPUT CURRENT @ 9 VDC WITHOUT CUB5RLY0 INPUT CURRENT @ 9 VDC WITH CUB5RLY0 CUB5R000 --- 10 mA 30 mA...

Open the catalog to page 2
CUB5 - 3

3 2.0 SETTING THE DIP SWITCHES SETTING THE INPUT DIP SWITCHES The meter has four DIP switches for Input A and Input B that must be set before applying power. SWITCH 1 LOGIC: Input A trigger levels VIL = 1.25 V max.; VIH = 2.75 V min.; VMAX = 28 VDC MAG: 200 mV peak input sensitivity; 100 mV hysteresis; maximum input voltage: „b40 V peak (28 Vrms); Must also have SRC switch ON. (Not recommended with counting applications.) SWITCH 2 SNK.: Adds internal 7.8 KƒÇ pull-up resistor to +9 to 28 VDC, IMAX = 3.8 mA. SRC.: Adds internal 3.9 KƒÇ pull-down resistor, 7.2 mA max. @ 28 VDC max. SWITCHES 3...

Open the catalog to page 3

All Red Lion Controls catalogs and technical brochures

  1. NT24k-16M12

    4 Pages

  2. RAM-6000 3G

    3 Pages

  3. HMI Brochure

    18 Pages

  4. N-View ® 2

    2 Pages

  5. 708M12-HV

    3 Pages

  6. ET-8MG-OEM-F

    2 Pages

  7. Protocol

    2 Pages

  8. RAM 9000

    3 Pages

  9. RAM 6000 LTE

    3 Pages

Archived catalogs

  1. LD

    16 Pages

  2. CUB4L

    4 Pages

  3. GEMINI 52

    8 Pages

  4. EPAX/MPAX

    8 Pages

  5. PAXLCR

    12 Pages

  6. PAXI

    32 Pages

  7. LPAX/MPAX

    4 Pages

  8. LEGEND

    8 Pages

  9. GEMINI 1 & 2

    8 Pages

  10. C48C

    6 Pages