C48C - 1

1 ! LCD, 7 SEGMENT, 2 LINE, 6 DIGIT DISPLAY, POSITIVE REFLECTIVE OR NEGATIVE TRANSMISSIVE MODELS WITH RED TOP LINE AND GREEN BOTTOM LINE BACKLIGHTING ! QUADRATURE SENSING ( Up to 4 times resolution) ! BI-DIRECTIONAL COUNTING, UP/DOWN CONTROL ! FIELD REPLACEABLE RELAY OUTPUT BOARDS ! STATUS INDICATORS FOR OUTPUTS ! NEMA 4X/IP65 SEALED BEZEL ! PARAMETER SECURITY VIA PROGRAMMABLE OPERATOR ACCESS PRIVILEGES AND PROTECTED VALUE MENU ! PROGRAMMABLE USER INPUTS AND FRONT PANEL FUNCTION KEY ! HORIZONTAL OR VERTICAL STACKING OF MULTIPLE UNITS ! 85 to 250 VAC OR 18 to 36 VDC/24 VAC POWERED UNITS ! RS485 SERIAL COMMUNICATIONS OPTION ! CHOICE OF NUMERIC DATA ENTRY MODES DESCRIPTION The Model C48 Counter is available as a Standard Counter or a Batch Counter. The Standard Counter is available with single or dual presets. The Batch Counter has a main process counter with dual presets and a secondary counter with a single preset. The secondary counter can be selected to function as a batch or a total counter. The C48C features a 7 segment, 2 line by 6 digit reflective or backlit LCD display. For the backlit versions, the main display line is red and shows the count value or the Batch/Total value when preset 3 or output 3 is viewed in the secondary display. The smaller secondary display line is green and can be used to view the prescaler value, preset values, output time values or Batch/Total count values (Batch model). The C48C offers a choice of nine programmable counting modes for use in applications requiring bi-directional, anti-coincidence, and quadrature counting. The unit may be programmed to register counts on both edges of the input signal providing frequency doubling capability. DIP switches are used for input configuration set-up and to provide a Program Disable function. Four front panel push-buttons are used for programming the operating modes and data values, changing the viewed display, and performing user programmable functions, e.g. reset, etc. The C48C can be configured for one of two numeric data entry methods, digit entry or automatic scrolling. The digit entry method allows for the selection and incrementing of digits individually. The automatic scrolling method allows for the progressive change of one through all digit positions by pressing and holding the “up” or “down” button. The Program Disable DIP switch, a user-programmable code value, and an external user input selected for Program Disable can be utilized to provide multi-level protection against unauthorized changes to data values and unit configuration. The C48 Counter has programmable User Inputs and a programmable front panel function key. The user inputs can be configured as sinking (active low) or sourcing (active high) inputs via a single plug jumper. The user inputs and the front panel function key can be configured to provide a variety of functions. The Standard Counter with Dual Presets is available with solid-state or Relay outputs. The Single Preset model has a solid-state and relay output. The Batch Counter has relay outputs for Output 2 and the Batch/Total Output 3, with Output 1 available as solid-state. The Batch Counter is also available with three solid-state outputs. For all C48 Counters, the solid-state outputs are available in a choice of NPN current sinking or PNP current sourcing, open-collector transistor outputs. All relay output boards are field replaceable. A Prescaler Output model is available as a Dual Preset, with solid-state outputs. The Prescaler Output is useful for providing a lower frequency scaled pulse train to a PLC or another external totalizing counter. The Prescaler Output provides a programmable width output pulse for every count or every 10 counts registered on the display. The optional RS-485 serial communication interface provides two-way communication between a C48 and other compatible equipment such as a printer, PLC, HMI, or a host computer. In multipoint applications (up to thirtytwo), the address number of each C48 on the line can be programmed from 0 to 99. Data from the C48 can be interrogated or changed, and alarm output(s) may be reset by sending the proper command code via serial communications. PC software, SFC48, allows for easy configuration of controller parameters. These settings can be saved to disk for later use or used for multi-controller down loading. On-line help is provided within the software. Optional programming software (SFC48) is available to program all unit configuration parameters. The software allows unit configurations to be created, uploaded, downloaded, and saved to a file for later use or multi-unit programming. The unit is constructed of a lightweight, high impact plastic case with a textured front panel and a clear display window. The front panel meets NEMA 4X/IP65 specifications when properly installed. Multiple units can be stacked horizontally or vertically. Modern surface-mount technology, extensive testing, plus high immunity to noise interference makes the C48 Counters extremely reliable in industrial environments. C48C SERIES - 1/16 DIN COUNTERS MODEL C48CS - SINGLE PRESET MODEL C48CD - DUAL PRESET MODEL C48CB - THREE PRESET BATCH DIMENSIONS “In inches (mm)” PANEL CUT-OUT Bulletin No. C48C-B Drawing No. LP0350 Revised 3/01 Tel +1 (717) 767-6511 Fax +1 (717) 764-0839 www.redlion-controls.com UL Recognized Component, File # E137808

Open the catalog to page 1
C48C - 2

2 SPECIFICATIONS 1. DISPLAY: 2 Line by 6 digit LCD display. Positive image reflective or negative image transmissive with red (top line) and green (bottom line) backlighting Main Display: 0.3" (7.62 mm) high digits Secondary Display: 0.2" (5.08 mm) high digits Annunciators: Value: PRS, 1, 2, and 3 Output: 01, 02, and 03. 2. POWER REQUIREMENTS: AC Versions: AC Power: 85 to 250 VAC, 50/60 Hz, 9 VA max. DC Power: 11 to 14 VDC @ 150 mA max. (Non PNP output models) Note: Models with PNP current sourcing outputs must be powered from AC. DC Versions (C48XXX1X): CONTINUOUS: DC Power: 18 to 36 VDC;...

Open the catalog to page 2

All Red Lion Controls catalogs and technical brochures

  1. NT24k-16M12

    4 Pages

  2. RAM-6000 3G

    3 Pages

  3. HMI Brochure

    18 Pages

  4. N-View ® 2

    2 Pages

  5. 708M12-HV

    3 Pages

  6. ET-8MG-OEM-F

    2 Pages

  7. Protocol

    2 Pages

  8. RAM 9000

    3 Pages

  9. RAM 6000 LTE

    3 Pages

Archived catalogs

  1. LD

    16 Pages

  2. CUB4L

    4 Pages

  3. GEMINI 52

    8 Pages

  4. CUB5

    16 Pages

  5. EPAX/MPAX

    8 Pages

  6. PAXLCR

    12 Pages

  7. PAXI

    32 Pages

  8. LPAX/MPAX

    4 Pages

  9. LEGEND

    8 Pages

  10. GEMINI 1 & 2

    8 Pages