BPROPAKRJ

BPROPAKRJ
1 / 12 PagesView full catalog

BPROPAKRJ

Product catalog summary
Features:
  • Simple and fast sizing and installation with range curves and selection charts based on R&D tests.
  • Kits operate between 30 Hz and 80 Hz, using matched water end and motor components.
  • Wiring is straightforward, similar to a standard three-wire control box.
  • Factory preset pressure at 50 psi, adjustable for higher pressures.
  • Three-phase output reduces wire cost, with switch input for pressure or float switch connection.
Kits Include:
  • CentriPro Three Phase Motor (1.5 – 5 HP, 230 V)
  • CentriPro Aquavar SOLO™ Controller with Transducer
  • Enduro Water End (pump)
  • Note: Pressure tanks are not included and must be ordered separately.
Aquavar SOLO™ Controller Features:
  • Versatile user interface with switch connection for optional pressure or level switch.
  • New current limit settings for CentriPro motors and dry well sensitivity switch.
  • Low pressure cut-off protection and transducer protection from power surges.
ProPak Kit Dimensions and Weights:
  • Controller and pump dimensions and weights vary by model, with specific details provided for each.
  • Pressure tanks must be ordered separately.
Performance Range and Components:
  • Detailed performance data for various models, including head, flow, and total dynamic head (TDH) at different operational points.
Wire Sizing:
  • Guidelines for maximum cable lengths to limit voltage drop to 5% for 230 V systems.
  • Examples provided for calculating total voltage drop and selecting appropriate wire sizes.
Diaphragm Tank Sizing and Pre-Set Pressure Recommendations:
  • Recommendations for tank sizing based on pump GPM and total volume.
  • Instructions for setting tank pressure to ensure smooth operation.
See more

Catalog excerpts

BPROPAKRJ-1

TECHNICAL BROCHURE AQUAVAR PrcPok Water Products

 Open the catalog to page 1
BPROPAKRJ-2

Red Jacket Water Products Residential Water Systems FEATURES Simple, fast sizing and installation. Range curves and selection charts generated from actual R&D tests. Kits configured for 30 Hz minimum and 80 Hz maximum operation. Kits use matched water end and motor (see component chart). Wiring is as easy as standard three-wire control box: • L1, L2 and Ground in from power supply • Red, Yellow, Black and Ground out to motor Pressure is factory preset at 50 psi with simple, fast, field adjustability for higher pressures. Three phase output to motor reduces wire cost. Switch Input for connecting...

 Open the catalog to page 2
BPROPAKRJ-3

Red Jacket Water Products Residential Water Systems PROPAK PERFORMANCE RANGE AND COMPONENTS MODEL HP 12RP1020 at Best Efficiency Flow (GPM) TDH (ft) at Maximum Runout WE Motor Controller Flow (GPM) TDH (ft) Order pressure tank separately, not included in kit AQUAVAR SOLO™ CONTROLLER – FEATURES New, more versatile user interface board • Provides switch connection for optional pressure or level switch • New current limit settings for all new CentriPro motors • Dry well sensitivity switch • Low pressure cut-off protection • 5 or 20 PSI pressure drop restart switch • Transducer better protected from...

 Open the catalog to page 3
BPROPAKRJ-4

TOTAL DYNAMIC HEAD

 Open the catalog to page 4
BPROPAKRJ-5

TOTAL DYNAMIC HEAD

 Open the catalog to page 5
BPROPAKRJ-6

TOTAL DYNAMIC HEAD

 Open the catalog to page 6
BPROPAKRJ-7

TOTAL DYNAMIC HEAD

 Open the catalog to page 7
BPROPAKRJ-8

TOTAL DYNAMIC HEAD

 Open the catalog to page 8
BPROPAKRJ-9

TOTAL DYNAMIC HEAD

 Open the catalog to page 9
BPROPAKRJ-11

⑥ Lengths in bold require 90ºC wire. Shading indicates 40º C maximum ambient. * Wire does not meet the N.E.C. ampacity requirement. The lengths in each of the Wire Sizing tables represent 100% of the allowable voltage drop when motor is running at full load. When sizing wire, the voltage drop of each wire segment must be included. The total must not exceed 100% of the allowable drop. Take for example a 1.5 HP motor with a distance from Service Entrance to Controller of 100' and 500' between the Controller and Motor. • Service Entrance to Controller (455' is from the S.E. to Controller chart)...

 Open the catalog to page 11
BPROPAKRJ-12

THREE PHASE, 4", MOTOR DATA Electrical Data, 60 Hertz, 3450 RPM, 4" Motors CentriPro # Diaphragm Tank Sizing and Pre-Set Pressure Recommendations: Diaphragm type (captive air) tanks are required on these systems. Table 1: Tank Sizing Selection Use Total Tank Volume, not drawdown volume, to select the proper tank size. The total tank volume should be approximately 20% of the pump’s maximum flow. For example, when using a 10 gpm pump the system requires a minimum 2 gallon (total volume) tank. The tank sizing recommendations are field proven to prevent objectionable pressure drops on start-up and...

 Open the catalog to page 12

All RED JACKET catalogs and technical brochures

  1. Grizzly

    2  Pages

  2. BRJVS R1

    4  Pages

  3. BRJ4BFLO R2

    8  Pages

  4. BRJBS R4

    4  Pages

  5. BRJCQUICK R3

    4  Pages

  6. BRJEZ R3

    2  Pages

  7. P2WW05

    4  Pages

  8. Enduro

    12  Pages

  9. E518/E610

    2  Pages

  10. RSDS & RWC5P

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.