RPX-1.5Q
10Pages

{{requestButtons}}

Catalog excerpts

RPX-1.5Q - 1

• AEC-Q100 qualified buck regulator power module with integrated shielded inductor • 36VDC input voltage, 1.5A output current • SCP, OCP, OTP, and UVLO protection • 3.0 x 5.0mm low profile QFN package • Wettable flanks for optical inspection on request • Enable, power good, soft start, and sync functions • -40 to 125°C operating temperature Features Power Module Description The RPX-1.5Q is an automotive-grade buck converter with an integrated inductor in a compact 3mm x 5mm x 1.6mm thermally-enhanced QFN package (wettable flank version available on request). The input range is from 4 to 36VDC, allowing 5V, 12V, or 24V supply voltages to be used. The output voltage can be set with two resistors in the range from 0.8 up to 30VDC. The output current is up to 1.5A and is fully protected against continuous short-circuits, output overcurrent, or over-temperature faults. DC/DC Converter Selection Guide Output Current [mA] Notes: Note1: Refer to “SAFE OPERATING AREA” Note2: Efficiency tested at VIN= 12VDC, full load, and VOUT= 3.3VDC Input Voltage Range [VDC] Part Number Model Numbering Automotive Grade Notes: Note3: Add suffix “-R” for tape and reel packaging Add suffix “-CT” for bag packaging (refer to“PACKAGING INFORMATION”) Specifications ABSOLUTE MAXIMUM RATINGS (exceeding these ratings may damage the device) Parameter Absolute Maximum Voltage VBST others Maximum Continuous Power Losses Junction Temperature Lead Temperature Storage Temperature Notes: Note4: Maximum power losses = (150-Tamb)/46. Exceeding this value will activate thermal protection. www.recom-power.com

Open the catalog to page 1
RPX-1.5Q - 2

Specifications OPERATING CONDITIONS (VIN= 12VDC, TJ= -40°C to +125°C, unless otherwise noted, typical values are at TJ= +25°C) Parameter Input Voltage Range VIN Under-voltage Lockout Threshold Rising VIN Under-voltage Lockout Threshold Hysteresis 330mV refer to “SAFE OPERATING AREA” Output Voltage Range Standby Current Quiescent Current Switching Frequency Feedback Voltage Feedback Current internal soft start Refer to “OUTPUT VOLTAGE TRIMMING” Notes: Note5: C2 (CFF) is required for low output voltages (<2VDC) The typical performance and circuit waveforms are shown in the Typical Performance...

Open the catalog to page 2
RPX-1.5Q - 3

Specifications CTRL AND SYNC OPERATING CONDITIONS (VIN= 12VDC, TJ= -40°C to +125°C, unless otherwise noted, typical values are at TJ= +25°C) Parameter CTRL Rising Threshold CTRL Falling Threshold CTRL Input Current CTRL Turn-off Delay 450kHz CTRL Frequency Range THERMAL OPERATING CONDITIONS (VIN= 12VDC, TJ= -40°C to +125°C, unless otherwise noted, typical values are at TJ= +25°C) Parameter Operating Junction Temperature case to ambient junction to case (refer to tc point) Thermal Impedance Thermal Shutdown auto recovery after cool down Notes: Note6: Tested with RECOM evaluation module:...

Open the catalog to page 3
RPX-1.5Q - 4

Specifications TYPICAL PERFORMANCE CHARACTERISTICS (VOUT= 1.8VDC, TJ= +25°C; tested with RECOM evaluation module: RPX-1.5Q-EVM-1) Deviation vs. Load Output Load [%] Output Load [%] TYPICAL PERFORMANCE CHARACTERISTICS (VOUT= 3.3VDC, TJ= +25°C; tested with RECOM evaluation module: RPX-1.5Q-EVM-1) Thermal Derating Efficiency vs. Output current Output Load [%] Output Load [%] Output Load [%] Output Load [%]

Open the catalog to page 4
RPX-1.5Q - 5

Specifications TYPICAL PERFORMANCE CHARACTERISTICS (VOUT= 5VDC, TJ= +25°C; tested with RECOM evaluation module: RPX-1.5Q-EVM-1) Efficiency vs. Output current Thermal Derating Output Load [%] Output Load [%] Output Load [%] Output Load [%] TYPICAL PERFORMANCE CHARACTERISTICS (VOUT= 12VDC, TJ= +25°C; tested with RECOM evaluation module: RPX-1.5Q-EVM-1) Efficiency vs. Output current Thermal Derating Output Load [%] Output Load [%] www.recom-power.com continued on next page REV.: 0/2022

Open the catalog to page 5
RPX-1.5Q - 6

Specifications TYPICAL PERFORMANCE CHARACTERISTICS (VOUT= 12VDC, TJ= +25°C; tested with RECOM evaluation module: RPX-1.5Q-EVM-1) Deviation vs. Load Output Load [%] Output Load [%] TYPICAL PERFORMANCE CHARACTERISTICS (VOUT= 15VDC, TJ= +25°C; tested with RECOM evaluation module: RPX-1.5Q-EVM-1) Thermal Derating Efficiency vs. Output current Output Load [%] Output Load [%] Output Load [%] Output Load [%]

Open the catalog to page 6
RPX-1.5Q - 7

Specifications TYPICAL PERFORMANCE CHARACTERISTICS (VOUT= 24VDC, TJ= +25°C; tested with RECOM evaluation module: RPX-1.5Q-EVM-1) Efficiency vs. Output current Output Load [%] Power Dissipation Output Load [%] Output Load [%] Output Load [%] ENVIRONMENTAL Parameter human-body model (HBM), ANSI/ESDA/JEDEC JS-001 charged-device model (CDM), JEDEC JESD22-C101 Moisture Sensitive Level Notes: Note7: The Moisture Sensitivity Level rating is according to the JEDEC industry standard classifications and peak solder temperature SAFETY AND CERTIFICATIONS Certificate Type (Safety)

Open the catalog to page 7
RPX-1.5Q - 8

Specifications DIMENSION AND PHYSICAL CHARACTERISTICS Parameter Dimension (LxWxH) Pad # Function PIN 1 ID Index Area Do not connect. Must be soldered to an isolated pad. Power Ground. Connect these pins to the power ground plane on the PCB Input Voltage. Connect a low-ESR low-inductance external bypass capacitor between this pin and GND as close to the pins as possible Power good source Analog ground. Reference ground of logic circuit. AGND is connected to PGND internally. Switch node. Connect 6, 7, and 8 to large copper pad for optimal heat dissipation. Output Voltage. Connect external...

Open the catalog to page 8
RPX-1.5Q - 9

Specifications SOLDERING Wave or Reflow etc. Profile Feature PB-Free Assembly maximum Temperature (TS_max) max Ramp Down Rate (from Ts_max to TP) max time from 25°C to Peak Temperature (TP) Other soldering methods (e.g. vapor-phase) are not verified and have to validate by the customer on his own risk. Time remaining around Peak Temperature For solder paste use a standard SAC Alloy such as SAC 305, type 3 or higher. Reflow time above liquids (217°C) should not exceed 150 seconds. The reflow time period during peak temperature of 240°C ±5°C should not exceed 30 seconds. minimum Temperature...

Open the catalog to page 9