• Fully railway approved for EN50155 (S2) applications • EN50121-3-2, EN50124-1, EN62368-1, EN61373, EN45545-2 • Plug&Play unit for natural convection cooling • Ultra wide range input for nominal 24V and 110V • Excellent efficiency and functionality • Parallel and redundant operation • Extremely reliable and robust Features Regulated Converter Description The chassis mountable RMD150-UW series DC/DC converter is designed for railway and transportation applications. The unit is designed with 12:1 input voltage range to cover the input voltages from 14,4VDC up to 154VDC for nominal 24, 36, 48, 72 and 110V in one range for all applications - on every vehicle worldwide. The isolated and regulated 24V output works with a reinforced isolation system. Due to the base plate mounting the unit operates with full power within the wide temperature for OT4+ST1&ST2 class from -40°C to +85°C and no addition cooling systems are necessary. Input reverse polarity protection, inrush current limitation, 10ms hold-up time, remote control, and output O-Ring diode and efficiency of up to 95% round up the functionality of this fully railway compliant Plug&Play unit. DC/DC Converter Model Numbering REACH compliant IEC/EN62368-1 pending EN50124-1 pending EN45545-2 pending EN50155 pending EN50121-3-2 compliant EN55011 compliant IEC/EN61000-4-2,3,4,5 compliant Input Voltage Range [VDC] Part Number Selection Guide Output Voltage Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) BASIC CHARACTERISTICS Parameter Input Voltage Range Input Surge Voltage Input Capacitance Under Voltage Lockout rising edge falling edge Output Power No Load Power Consumption Inrush Current Input Current Range active inrush current limitation continued on next page www.recom-power.com

Open the catalog to page 1
RMD150-UW - 2

Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) BASIC CHARACTERISTICS (continuous) Parameter Standby Current (shutdown by remote) Output Current Range parallel operation refer to “PARALLEL OPERATION” Output Voltage Trimming Minimum Load Output Voltage Rise Time Hold-up Time ON/OFF CTRL by using CTRL ON/OFF function Start-up Time Input Current of CTRL pin Internal Operating Frequency Output Ripple and Noise over full input and load range, 20MHz BW Maximum Capacitive Load Input Voltage Range Output Power [%] Constant Current / Constant...

Open the catalog to page 2
RMD150-UW - 3

Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) REGULATIONS Parameter Output Accuracy Line Regulation low line to high line, full load Load Regulation 10-100% load 10-90% load, VIN= 16.8-137VDC Transient Response Parameter Input Fuse recovery time Input Reverse Polarity Protection active protected Over Voltage Protection (OVP) Over Voltage Category (OVC) Over Current Protection (OCP) routine test Isolation Capacitance auto recovery Isolation Resistance shut down, auto recovery Over Temperature Protection (OTP) T25A, slow blow type constant...

Open the catalog to page 3
RMD150-UW - 4

Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) ENVIRONMENTAL Parameter Value with derating Operating Temperature Range without derating according to EN50155 operating temperature class OT4 and extended operating temperature class ST1 & ST2 without derating for 15 minutes Temperature Coefficient Operating Altitude Operating Humidity Conformal Coating Maximum Baseplate Temperature Pollution Degree IP Rating Mechanical Shock Vibration 10G, 11ms, 18 times, half sine 1,5G, 5-200Hz, 4 hours along x,y and z axis Fire Protection on Railway...

Open the catalog to page 4
RMD150-UW - 5

Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) ENVIRONMENTAL (RAILWAY STANDARDS) Parameter Condition Temperature: +70°C/+25°C Number of cycles: 2 Time 2x 24h Cyclic damp heat test Random Vibration, unit not powered during test Frequency range 5-150Hz with -6db/oct from 20 to 150Hz Vertical axis 5.72m/s² for 5h [ASD 0.964(m/s²)²/Hz] Transverse axis 2.55m/s² for 5h [ASD 0.192(m/s²)²/Hz] Longitudinal axis 3.96m/s² for 5h [ASD 0.461(m/s²)²/Hz] EN 61373 clause 9, class B Body mounted Half-sine shock, unit powered during test Vertical axis...

Open the catalog to page 5
RMD150-UW - 6

Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) DIMENSION AND PHYSICAL CHARACTERISTICS Parameter Dimension (LxWxH) Input Connector CAGE CLAMP® CON1 (WAGO 745-3153) # Function AWG Wire diameter -Vin 28-12 0.08-4mm² 1 +Vin 28-12 0.08-4mm² 2 PE 28-12 0.08-4mm² 3 Output Connector CAGE CLAMP® CON2 (WAGO 745-3152) # Function AWG Wire diameter +Vout 28-12 0.08-4mm² 4 -Vout 28-12 0.08-4mm² 5 Side View Bottom View wire stripping length: 8-9mm Conductor connection direction to PCB: 45° 2X M3 optional heatsink fixation. Max 3.0mm, max tightening...

Open the catalog to page 6
RMD150-UW - 7

DC/DC Converter Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) Dimension Drawing (mm) 188.6 2X M3 optional heatsink fixation. Max 3.0mm, max tightening torque: 1.3Nm Compatible Connector Phoenix DFMC 1,5/ 8-STF-3,5 – 1790357 2X M3 optional heatsink fixation. Max 3.0mm, max tightening torque: 1.3Nm 2.0 Mounting Dimensions 2X M3 optional heatsink fixation. Max 3.0mm, max tightening torque: 1.3Nm For operation of the DC/DC converter the PE connection at the intended connection point as part of the overall EMC concept is mandatory. Natural...

Open the catalog to page 7
RMD150-UW - 8

Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) PARALLEL OPERATION -VIN Here the example of three parallel connected units. CS1/CS2 is a double connection of the same pin to be able to connect more than two units. BLOCK DIAGRAM Input Filter FORWARD CONV. with ACTIVE CLAMP ORING Mosfet Synchronous Rectifier HOLD UP TIME MODULE AUXILIARY Converter PRIMARY Control SECONDARY Control PACKAGING INFORMATION Parameter Packaging Dimension (LxWxH) Packaging Quantity Storage Temperature Range The product information and specifications may be subject...