RAC05-K/C14
6Pages

{{requestButtons}}

Catalog excerpts

RAC05-K/C14 - 1

5 Watt Single Output The RAC05-K/C14 is a unique patented design that combines a mains filter and isolated power supply in the same case as a mains input filter alone, at a cost lower than many mains filters. It fits into a standard IEC “kettle connector” mounting hole, so installation time is only a few seconds. The touchable output spade terminals are safe extra-low voltage (SELV) available in 3.3V, 5V, 12V, 15V and 24V DC output voltages and are protected against short circuits, overload and overvoltage. The metal case offers secure fixing and enhances thermal dissipation allowing an operating temperature from -25°C to +70°C. The RAC05-K/C14 is ideal for powering single board computers such as the Raspberry Pi (including touchscreen), Arduino, BBC Micro:bit, etc. Regulated Converter AC/DC Converter • Unique patented design • Isolated power supply with integrated mains filter • Packaged inside of line filter case • Safe, touchable DC outputs • Easy installation • Worldwide standard IEC input • 85-264VAC universal input voltage Selection Guide Notes: Note1: Efficiency is tested at nominal input and full load at +25°C ambient Note2: Max Cap Load is tested at nominal input and full resisitive load UL/IEC/EN62368-1 certified IEC/EN60950-1 certified FCC Part 15 compliant ANSI C63.4 compliant IEC/EN61204-3 compliant EN55014-1 / +2 compliant EN55024 compliant EN55032 compliant CB Report Model Numbering RAC05-__ SK/C14 nom. Output Power Output Voltage C14 input plug (male) Single

Open the catalog to page 1
RAC05-K/C14 - 2

Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) BASIC CHARACTERISTICS Parameter Internal Input Filter Input Voltage Range (3,4) Input Current Input Power= Inrush Current No Load Power Consumption ErP Standby Mode Conformity (Output Load Capability) Input Frequency Range Minimum Load Power Factor Start-up Time Rise Time Hold-up Time Internal Operating Frequency Output Ripple and Noise Notes: Note3: The products were submitted for safety files at AC-Input operation Note4: Refer to “Line Derating” Output Load [%] Output Load [%] continued on...

Open the catalog to page 2
RAC05-K/C14 - 3

Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) Efficiency vs. Load RAC05-12SK/C14 Output Load [%] Output Load [%] Output Load [%] REGULATIONS Parameter Output Accuracy Line Regulation Load Regulation Transient Response www.recom-power.com low line to high line, full load 25% load step change recovery time

Open the catalog to page 3
RAC05-K/C14 - 4

Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) PROTECTIONS Parameter Input Fuse Short Circuit Protection (SCP) Hiccup, automatic restart Over Voltage Protection (OVP) Over Voltage Category Over Current Protection (OCP) 125% - 195%, Hiccup auto recovery Isolation Voltage (6) Isolation Resistance Isolation Capacitance Insulation Grade Leakage Current 0.25mA max. Notes: Note5: Refer to local safety regulations if input over-current protection is also required Note6: For repeat Hi-Pot testing, reduce the time and/or the test voltage...

Open the catalog to page 4
RAC05-K/C14 - 5

Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) SAFETY AND CERTIFICATIONS Certificate Type (Safety) Report / File Number Audio/video, information and communication technology equipment - Safety requirements (CB) Audio/video, information and communication technology equipment - Safety requirements (LVD) Audio/video, information and communication technology equipment - Safety requirements E224736 Information Technology Equipment, General Requirements for Safety (CB) Information Technology Equipment, General Requirements for Safety...

Open the catalog to page 5
RAC05-K/C14 - 6

Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) Dimension Drawing (mm) 26.8 Single VAC in (L) Earth VAC in (N) +Vout Earth -Vout FC= fixing centers Tolerance: xx.x= ±0.5mm Mounting hole dimensions PACKAGING INFORMATION Parameter Packaging Dimension (LxWxH) Packaging Quantity Storage Temperature Range Storage Humidity The product information and specications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The...

Open the catalog to page 6