ADD:No.909, Middle Section 4, West Airport Ave, Southwest Airport Economic Development Zone, Shuangliu County, Chengdu, Sichuan Province, China Choose REACH
Open the catalog to page 1To be the First Choice for Global Customers CONTENTS Electromagnetic Brake Product Lines Spring-Applied Brakes----------- REB04 Brakes for Electric Motors----- REB05 Brakes for Electric Motors----- REB05C Fully Enclosed Brakes------ REB05 Fully Enclosed Super-Thin Brakes REB23 Wind Turbine Yaw System Brakes REB05 Wind Turbine Pitch System Brakes REB05F Wind Vane Brakes--------- REB08 End-Cap Integrated Brakes---- REB31 Block-Type Elevator Brakes---- REB33 Overlapping Disc-Type Elevator Brakes REB34 Disc-Type Elevator Brakes-------- Power-on Brakes---- Rectifiers, Microswitches, Accessories
Open the catalog to page 2► Electromagnetic Brake Product Lines ^ General Industrial Electromagnetic Brakes REB04 Brakes for Electric Motors General Industrial Electromagnetic Brakes - Suitable for industrial motion control applications, - including wind power, aerial work platforms, construction machinery, ships, port machinery, elevators, mobility scooters, etc. Technical Data High stability & reliability i Rapid response J Power-on Brakes Frame - Suitable for applications requiringfrequentstart-stop, precision braking, - and energy savings, such as automatic vehicle side doors, forklifts, platform screen
Open the catalog to page 3The mounting bore tolerance is H7, and the keyway dimensions conform to DIN 6885/1 (GB/T1095-79)JS9. Bore diameters show in bold are standard sizes. REB04 Double Brakes Technical Data ® Til Armature Release Time ® T1 BrakingTime T2 Release Time(Armature EngagementTime) © T12 Torque Rise Time © All the above time parameters above are obtained under DC-side control
Open the catalog to page 4REB05 Brakes for Electric Motors Technical Data REB05 Super-Thin Brakes Technical Data Unit: mm Note: Some specifications use dual-voltage control. Please confirm with our company when selecting the model.
Open the catalog to page 5REB05C Fully Enclosed Brakes REB05 Fully Enclosed Super-Thin Brakes Technical Data
Open the catalog to page 6REB05 Micro Brakes © Basic Assembly with Integrated Rectifier Accessory Description Manual Release Handle® The manual release handle is used to manually release the brake during equipment installation and commissioning. Frame Rectifiers and Connection Boards Technical Data Rectifier © To assist customers in designingcompact micro motors, we offer built-in rectifiers that can be installed on the end face orthe outer cylindrical surface of the brake. Connection Board © To facilitate the installation of speed controllers and other motor accessories insidethe motor housing, the mounting dimensions...
Open the catalog to page 7REB23 Wind Turbine Yaw System Brakes Technical Data Technical Data Unit: mm
Open the catalog to page 8REB05F Wind Vane Brakes REB08 End-Cap Integrated Brakes Installation and Operating Instructions Installation and Operating Instructions 9. Hexagon Socket Head Cap Screw 10.Spring Washer II. Bearing Retaining Plate 12. Phillips Pan Head Screw 14. Power Supply Mounting Bracket 15. Power Supply Mounting Screw Fan Cover Mounting Dimensions Brake Mounting Dimensions Brake Mounting Step Outer Diameter Distance from Mounting Face to Bearing Bore Bottom Mounting Shaft Diameter Bearing Model Number Technical Data Technical Data Unit: mm
Open the catalog to page 9REB09 Forklift Brakes Technical Data
Open the catalog to page 10REB33 Overlapping Disc-Type Elevator Brakes Technical Data Unit: mm
Open the catalog to page 11Installation and Operating Instructions ► Power-on BrakesREB03 Power-on Brakes REB03-A: Direct mountingtype; REB03-B: Shaft mountingtype Technical Data Technical Data Frame Size
Open the catalog to page 12Performance and Installation Dimension Drawing 4-Wire Half-Wave or Full-Wave Rectifiers ► Rectifiers ® Plastic housing with compactdesign © Optionalwiringmethodallowsquickinstallation © Brake operating power is DC supply, if an external AC supply is used, the following rectifier specifications can be selected Powered by Motor Braking Slowly Powered by Separate Mains MW Braking at moderate speed 6-Wire Half-Wave or Full-Wave Rectifiers InputVoltage (AC) Installation Dimension Drawing
Open the catalog to page 13Note: Forthe wiringofthe 6-wire half-wave rectifierwith a 380VAC input, please refertothe "Fast Engagement RectifierWiring Diagram". Fast Engagement Rectifiers No. Fast Engagement Rectifiers Fast Braking Rectifiers Installation Dimension Drawing ► Microswitch ® Microswitches are used in applications requiring air gap monitoring. They offer two control logics and have a lifespan of over one million cycles. ® When the armature is engaged by the stator, the brake is released and the microswitch detects the engagement, allowing the motorto start. If the air gap exceeds its limit, the microswitch...