Overview
The RLW Industrial Weighing Compression Load Cell is a device that converts load or force into an electrical signal. It is designed to be bolted down using two mounting holes, with force applied to a threaded hole. Care must be taken to avoid exceeding the load cell's capacity.

Specifications
  • Excitation/Supply: Acceptable range is 0 to 15V, calibrated at 10V.
  • Output: 2mV/V ±10%.
  • Zero Balance: 2% F.S.
  • Bridge Resistance: 350 Ohms.
  • Linearity Error: ±0.03% F.S.
  • Hysteresis: ±0.03% F.S.
  • Repeatability: ±0.03% F.S.
  • Resolution: Infinite.
  • Temperature Coefficient (Zero): ±0.002% F.S./°F (typical).
  • Temperature Coefficient (Span): ±0.002% F.S./°F (typical).
  • Operating Temperature Range: -4°F to 140°F.
  • Compensated Temperature Range: 14°F to 104°F.
  • Ingress Protection: IP67.
  • Over-range Capacity: 50%.
  • Major Construction Material: Steel.
  • Electrical Termination: 9.8ft integral cable.

Model Variants
The RLW series includes models with varying capacities from 10kgf to 1500kgf, with dimensions and specifications provided for each model.

Contact Information
RDP Electrosense, 2216 Pottstown Pike, Pottstown, PA 19465, USA. Tel: 610-469-0850, 800-334-5838. Fax: 610-469-0852. Email: [email protected].

Note: Specifications are subject to change without notice due to ongoing development.
See more

Catalog excerpts

Model RLW Industrial Weighing Compression Load Cell-1

Load Model RLW Industrial Weighing Compression Load Cell ● ● ● Very high accuracy Infinite resolution Low cost A load cell or force sensor is a device which converts load or force into an electrical signal. This series of compression load cell is bolted down using the two mounting holes and the force applied to the threaded hole. Care should be taken to ensure that the load sensor is not exposed to load or force in excess of its capability. The range of compression load cell selected should therefore be appropriate for the maximum force (including transient forces) that can be applied to it. This series of transducer is a strain gauge type transducer and has a mV output which may require an amplifier. We can offer a variety of high quality, low noise and high precision strain gauge amplifiers.

 Open the catalog to page 1
Model RLW Industrial Weighing Compression Load Cell-2

Specification Excitation/supply (acceptable) Excitation/supply (calibrated) Output Zero balance Bridge resistance Linearity error Hysteresis Repeatability Resolution Temperature coefficient (zero) Temperature coefficient (span) Operating temperature range Compensated temperature range Ingress protection (IP) Over-range capacity Major construction material Electrical termination All dimensions and specifications are nominal. Due to our policy of on-going development, specifications may change without notice. Any modification may affect some or all of the specifications for our equipment. RDP Electrosense...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.