Model RLS Single-Point Compression Load Cell
2Pages

{{requestButtons}}

Catalog excerpts

Model RLS Single-Point Compression Load Cell - 1

Load Model RLS Single-Point Compression Load Cell ● ● ● Very high accuracy Infinite resolution Low cost A load cell or force sensor is a device which converts load or force into an electrical signal. A single-point compression load cell is designed for such applications as weighing scales. Care should be taken to ensure that the load sensor is not exposed to load or force in excess of its capability. The range of compression load cell selected should therefore be appropriate for the maximum force (including transient forces) that can be applied to it. This series of transducer is a strain gauge type transducer and has a mV output which may require an amplifier. We can offer a variety of high quality, low noise and high precision strain gauge amplifiers.

Open the catalog to page 1
Model RLS Single-Point Compression Load Cell - 2

Specification Excitation/supply (acceptable) Excitation/supply (calibrated) Output Zero balance Bridge resistance Linearity error Hysteresis Repeatability Resolution Temperature coefficient (zero) Temperature coefficient (span) Operating temperature range Compensated temperature range Ingress protection (IP) Over-range capacity Major construction material Electrical termination 0 to 15V 10V 2mV/V ±10% 2% F.S. 350 Ohms ±0.02% F.S. ±0.02% F.S. ±0.02% F.S. Infinite ±0.0014% F.S. /°F (typical) ±0.0014% F.S. /°F (typical) -4°F to 140°F 14°F to 104°F 65 50% Aluminium alloy 9.8ft (integral cable)...

Open the catalog to page 2

All RDP Electronics catalogs and technical brochures

Archived catalogs