Unfors Xi

Unfors Xi

Unfors Xi

Product catalog summary
Specifications Overview:
The Unfors Xi Platinum Edition is a comprehensive radiation measurement device with various detectors for different applications, including R/F, mammography, CT, and survey measurements. It offers a wide range of dose and dose rate measurements with specific uncertainties and active compensation features.

Dose and Dose Rate Measurements:
- R/F High Dose: Range from 10 µGy to 9999 Gy with a trigger level of 100 µGy/s and an uncertainty of 5% or ±10 µGy.
- R/F Low Dose Rate: Range from 10 nGy/s to 1 mGy/s with a minimum peak trigger level of 100 nGy/s and similar uncertainty.
- Mammography Dose: Range from 5 µGy to 9999 Gy with a trigger level of 10 µGy/s and an uncertainty of 5% or ±5 µGy.

kV/kVp Measurements:
- Range from 35 to 160 kV/kVp with an uncertainty of 2% for total filtrations from 2.5 mm Al up to 1 mm Cu.

Exposure Time and Pulse:
- Exposure time ranges from 1 ms to 999 s with an uncertainty of 0.5% or 0.2 ms.
- Pulse range from 1 to 9999 pulses with specific peak trigger levels for R/F low and high.

Detector Specifications:
- Unfors Xi Base Unit: Compact size, automatic power-off, and rechargeable power source with a battery life of 10-20 hours.
- Unfors Xi R/F Detector: Lightweight with a dose range of 10 nGy to 9999 Gy and specific trigger levels.
- Unfors Xi Mammography Detector: Designed for specific beam qualities with active compensation and uncertainty specifications.

General Features:
- EMC tested according to EN standards, automatic reset, and a temperature range of 15-35°C.
- Data transfer via RS-232 or Bluetooth with XML data format.
- Software support with Unfors Xi View for data recording and export.

Additional Detectors:
- CT Detector: Includes a phantom adapter, with specifications for dose range, uncertainty, and energy dependence.
- Light Detector: Measures luminance and illuminance with specific calibration and traceability standards.
- Survey Detector: Measures dose and dose rate with manual trigger and response time specifications.

Unfors Xi mA/mAs Detector:
- Measures mA and mAs with specific ranges and uncertainties, including over-voltage protection and reproducibility.

Software and Communication:
- Unfors Xi View supports various Windows operating systems and communicates via RS-232 or Bluetooth with a nominal operating distance of 100 m.
See more

All RaySafe catalogs and technical brochures

  1. RaySafe i3

    8  Pages

  2. RaySafe DXR+

    4  Pages

  3. RaySafe x2

    8  Pages

  4. RaySafe ThinX

    3  Pages

  5. RaySafe Solo

    5  Pages

  6. RaySafe Xi

    8  Pages

Archived catalogs

  1. Mammographic

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.