Product catalog summary
Main Features
The AVS-N Series vertical benchtop autoclaves are designed for sterilizing general labware and metal utensils. They are compact, economical, and efficient, requiring only a power source for installation and maintenance.
Specifications
Constructed from high-quality stainless steel (AISI-316L), these autoclaves feature Incoloy® 825 heating elements and are controlled by a PID microprocessor with multiple programs. The AES-12 model includes an integrated printer and optional data management software.
Safety Features
Safety is ensured with an overpressure safety valve, thermally insulated lid, overtemperature safety thermostat, and a pneumatic door locking system.
Intended Use
The AVS-N Series is suitable for sterilizing laboratory waste bags, plastics, glassware, liquids, and metal utensils, ideal for small laboratories and clinics.
Working Principle
The sterilization process includes heating to produce steam, maintaining temperature for sterilization, and cooling. The AES-12 model offers enhanced control for liquid sterilization.
Control Panels
The AES-8 features a digital microprocessor with a compact screen, while the AES-12 offers a larger screen with more program options and multilingual support.
Accessories
Available accessories include stainless steel wire baskets, a transport trolley, cable glands for external probes, a flexible core temperature probe, and printers for data logging.
Advantages
The AVS-N Series is economical, compact, and user-friendly, with advanced features for precise control and safety, suitable for small to medium-sized facilities.
Technical Summary
Available Models: AES-8 and AES-12
General Classification: Recommended for small facilities and general laboratories, these benchtop autoclaves are top-loading with a round chamber profile.
Recommended Load Types: Suitable for culture media, liquids, laboratory waste bags, glassware, and porous solids (AES-12 only).
Sterilization Technology Features: Utilizes heating elements for steam generation and gravity displacement for air purge. Data transfer is facilitated via RS-232, with options for integrated or external printers.
Sterilization Chamber and Door Specifications: The AES-8 has an 8L chamber, while the AES-12 has a 15L chamber. Both models feature AISI-304 external material and AISI-18/10 or AISI-316L chamber material. The door opens vertically with a bayonet wheel mechanism and is thermally insulated.
User Interface and Microprocessor: Equipped with a digital LCD display, the AES-8 offers 1 program, while the AES-12 offers 10 programs. Features include automatic microprocessor control, timer start, and special cycles like agar mode and solids fast cooling.
Other Specifications: Includes a multiple-use water sterilization chamber, flexible core temperature probe (AES-12), and adjustable cycle parameters. The AES-12 also offers electric customization and third-party qualification services.
Safety Features: Both models include a safety valve, thermostat, pneumatic door blocking system, and various alarms. The AES-12 also features an open door sensor.
Regulations: Complies with international standards such as EN-61010-1, EN-61010-2-040, EN-61326, AD 2000 Merkblatt, and EU directives on low voltage, electromagnetic compatibility, and pressure equipment.
General Features: The AES-8 and AES-12 offer adjustable sterilization temperatures and times, with a fully automatic control system. The external material is AISI-304 stainless steel, and the heating elements are made of Incoloy® 825.
Specifications: The AES-8 has a total chamber volume of 8L and a net weight of 12 kg, while the AES-12 has a 15L chamber and weighs 38 kg. Both models operate at 230V and 50/60 Hz frequency.
See more

Catalog excerpts

VERTICAL BENCHTOP AUTOCLAVES WITHOUT DRYING - AVS-N SERIES-1

VERTICAL BENCHTOP AUTOCLAVES WITHOUT DRYING AVS-N SERIES CLASSIC LINE COMPACT, ECONOMIC, ROBUST PERFORMANCE AND LIMITED LABORATORY RESOURCES CONSUMPTION

 Open the catalog to page 1
VERTICAL BENCHTOP AUTOCLAVES WITHOUT DRYING - AVS-N SERIES-2

Vertical benchtop autoclaves without drying The AVS-N Series vertical benchtop autoclaves with top-loading access cover the fundamental needs for general labware and metal utensils sterilization in many facilities with the aim of streamlining the sterilization workflow. A compact footprint together with the optimization of resources such as water, power and operating time results in an affordable and efficient solution to manage laboratory workload in small facilities. STERILIZATION OF LABORATORY WASTE BAGS, PLASTICS, GLASSWARE, LIQUIDS AND METAL UTENSILS MAIN FEATURES ECONOMIC AND DURABLE A...

 Open the catalog to page 2
VERTICAL BENCHTOP AUTOCLAVES WITHOUT DRYING - AVS-N SERIES-3

Sterilization chamber and door made of high quality stainless steel grade AISI-316L extremely resistant to corrosion*. Temperature control by a PT-100 Class A temperature probe located within the sterilization chamber. Equipment built following all applicable European Union quality, regulatory and safety standards. Faster cooling phase in solids sterilization cycles through a steam release manual valve at the end of the sterilization. Heating by powerful electric elements made of Incoloy® 825 assembled inside the sterilization chamber and shielded by a protective grid. Adjustable temperature...

 Open the catalog to page 3
VERTICAL BENCHTOP AUTOCLAVES WITHOUT DRYING - AVS-N SERIES-4

Vertical benchtop autoclaves without drying WORKING PRINCIPLE AVS-N Series autoclaves provide a simple and straightforward solution for the multiple sterilization needs of general laboratories including biological waste, contaminated media, small metal utensils, glassware and other laboratory items. The load has to be placed into the pressure vessel basket and, after manually filling the tank with purified water, the equipment starts to heat up and purge until the set combination of sterilization time and sterilization temperature is reached. STANDARD AVS-N SERIES STERILIZATION CYCLE HEATING...

 Open the catalog to page 4
VERTICAL BENCHTOP AUTOCLAVES WITHOUT DRYING - AVS-N SERIES-5

AES-8 CONTROL PANEL MULTIPLE PUSH-BUTTONS AND PILOT LIGHTS FOR YOUR COMFORT AND EASE OF USE • To assist you while programming a sterilization cycle, the control panel has 2 pilot lights and 5 intuitive push-buttons. • At the end of the sterilization cycle an acoustic alarm sounds. Detail of AES-8 main control panel. 4 MODES TO REGULATE THE STERILIZATION CYCLE • Indefinitely at a set temperature. DIGITAL MICROPROCESSOR AND COMPACT SCREEN • The screen shows current chamber temperature, sterilization parameters and error messages. • Indefinitely at a set temperature after an initial delay. • During...

 Open the catalog to page 5
VERTICAL BENCHTOP AUTOCLAVES WITHOUT DRYING - AVS-N SERIES-6

Vertical benchtop autoclaves without drying AES-8 THE PERFECT AUTOCLAVE FOR ENTRY LEVEL USERS OF SMALL FACILITIES LOOKING FOR AN ECONOMIC, RELIABLE AND EASY TO USE BENCHTOP AUTOCLAVE WITH A SMALL FOOTPRINT. INTENDED USE • Suitable to sterilize glassware, plastics, laboratory waste bags, small metal utensils and small volumes of liquids and culture media. RECOMMENDED SETTINGS AND USERS • Entry level users of small facilities such as small laboratories or small clinics looking for an economic benchtop autoclave with toploading access. FEATURES • Sterilization chamber made of AISI-18/10 stainless...

 Open the catalog to page 6
VERTICAL BENCHTOP AUTOCLAVES WITHOUT DRYING - AVS-N SERIES-7

AES-12 THE PERFECT AUTOCLAVE FOR SMALL CLINICS AND RESEARCH FACILITIES LOOKING FOR AN ECONOMIC, VERSATILE AND RELIABLE BENCHTOP AUTOCLAVE WITH A SMALL FOOTPRINT THAT IS COMPATIBLE WITH MULTIPLE APPLICATIONS. INTENDED USE • Suitable to sterilize plastics, small metal utensils, laboratory waste bags, culture media, glassware and liquids. RECOMMENDED SETTINGS AND USERS • Professional users of small and mediumsized facilities such as small laboratories or small clinics looking for an economic benchtop autoclave with top-loading access. FEATURES • Sterilization chamber made of AISI-316L stainless...

 Open the catalog to page 7
VERTICAL BENCHTOP AUTOCLAVES WITHOUT DRYING - AVS-N SERIES-8

Vertical benchtop autoclaves without drying Accessories STAINLESS STEEL WIRE BASKETS Reference Dimensions For autoclaves with the following chamber volumes FLEXIBLE CORE TEMPERATURE PROBE PT-100 CLASS A • After installing this accessory, the temperature regulation of the sterilization cycle can either be controlled by the main chamber temperature sensor or both the main chamber temperature sensor and the temperature sensor of the flexible core temperature probe. • The temperature control by the flexible core temperature probe is especially advantageous for processes involving the sterilization...

 Open the catalog to page 8
VERTICAL BENCHTOP AUTOCLAVES WITHOUT DRYING - AVS-N SERIES-9

WATER DISTILLER INTEGRATED THERMAL PRINTER • Forced air water distiller with stainless steel interior, a capacity of 4L and a distillation volume output of 1,5L/h. • Prints program number, cycle number, temperature, date and hour of the run and error messages. • Selectable printing cadence between 10 and 240 seconds. • Compatible only with AES-12. • Must be installed in our facilities. Reference: IT/AES-12 Consumable: Paper: PAPER-IT TABLE TOP DOT MATRIX PRINTER • Prints program number, cycle number, temperature, date and hour of the run and error messages. • Used with RS-232 connection. • Selectable...

 Open the catalog to page 9
VERTICAL BENCHTOP AUTOCLAVES WITHOUT DRYING - AVS-N SERIES-10

Vertical benchtop autoclaves without drying TECHNICAL SUMMARY OF AVS-N SERIES AUTOCLAVES Available models General classification Small facilities General laboratory Equipment placement Load direction Chamber profile Culture media and liquids Recommended type of load Laboratory waste bags Porous solids and wrapped loads Glassware Sterilization technology features Transfer of data Batch printers Method to generate steam Heating elements Gravity displacement External printer Sterilization chamber volume External building material Sterilization chamber material Sterilization chamber and door specifications...

 Open the catalog to page 10
VERTICAL BENCHTOP AUTOCLAVES WITHOUT DRYING - AVS-N SERIES-11

TECHNICAL DATA Specifications References Total/usable volume of the chamber L Usable dimensions of the chamber Ø x H mm External dimensions L x D x H mm Frequency Hz *Other voltages and electrical configurations available on request. Safety features General features • Safety valve. • Safety thermostat with manual rearm for the heating elements. • Pneumatic door blocking system while positive pressure exists inside the sterilization chamber. • Open door sensor (Only AES-12 model). • Thermally insulated door. • Heating elements cover. • Several visual and acoustic safety and warning alarms. Available...

 Open the catalog to page 11