Top line vertical autoclaves with state-of-the-art technology TLV Series
Open the catalog to page 1Why choose RAYPA? Expert manufacturer, original design, global brand GLOBAL REACH With half a century of experience, we have a long list of satisfied customers around the world. Currently, we export 85% of our annual turnover and have a stable network of distributors with presence in over 100 countries. EXPERT MANUFACTURER After more than 50 years in the industry, RAYPA is a global leader in the manufacture of laboratory autoclaves. Each of our autoclaves is designed and manufactured entirely within our modern facility equipped with the latest technology. INNOVATION AND QUALITY Our products feature...
Open the catalog to page 2TLV-DUAL Series Autoclaves with super-drying and fast cooling system Culture media and liquids Laboratory waste bags Objects with complex geometries Plastics and metal objects Biohazardous waste Hermetically sealed items Porous solids and wrapped objects In the prevacuum phase, the air of the chamber is purged with multiple vacuum pulses. After the first vacuum pulse, the steam generator is activated, injecting saturated steam into the chamber until the required temperature is reached. This temperature is accurately sustained for the predefined duration to sterilize the load. Subsequently, the...
Open the catalog to page 3TLV-FA Series TLV-PD Series Autoclaves with fast cooling system Autoclaves with super-drying system Culture media and liquids Laboratory waste bags Culture media and liquids Laboratory waste bags Porous solids and wrapped objects Plastics and metal objects Biohazardous waste Plastics and metal objects Biohazardous waste Objects with complex geometries Hermetically sealed items Advanced sterilization of liquid loads COOLING TIME In the prevacuum phase, the air of the chamber is purged with multiple vacuum pulses. After the first vacuum pulse, the steam generator is activated, injecting saturated...
Open the catalog to page 4TLV-S Series Versatile autoclaves for general applications Culture media and liquids Laboratory waste bags Plastics and metal objects Biohazardous waste Operation In the prevacuum phase, the air of the chamber is purged with a single vacuum pulse. Then, the steam generator is activated, injecting saturated steam into the chamber until the appropriate temperature is reached. This temperature is accurately sustained for the predefined duration to sterilize the load. Finally, a natural cooling phase begins.
Open the catalog to page 5"Engineered to exceed your requirements, even the most demanding ones" Safety first, comfort always Prioritizing safety and user-friendliness, our autoclaves ensure a secure operation for both operators and the items being sterilized. Exceptional build quality We build our products using only top-tier materials, ensuring unrivaled durability and operational reliability in the most demanding environments. Swift installation Our autoclaves are designed for easy installation, ensuring they are immediately operational and can be relocated as needed to meet changing space requirements. Modern design...
Open the catalog to page 6Exceptional build quality Modern design Our autoclaves are designed to deliver exceptional durability and outstanding operational reliability. All the features and components necessary to perform any type of application. The external housing is made of AISI-304 stainless steel, while the sterilization chamber is made of high-quality AISI-316L stainless steel, providing exceptional corrosion resistance. All our autoclaves are manufactured in compliance with the European Pressure Equipment Directive (PED) 2014/68/EU requirements. Optionally, they can be manufactured under ASME VIII Div-1 and CRN...
Open the catalog to page 7State-of-the-art innovation Our autoclaves are designed with advanced engineering and exceptional quality in every detail, ensuring consistent and fully traceable results. Modern 7” touchscreen display Enhanced batch control Navigate all device features effortlessly with our modern touchscreen display, designed for an intuitive user experience, ensuring clarity and precision in every interaction. Comprehensive and automated batch process management. It allows you to schedule and monitor multiple batches, as well as generate detailed reports, ensuring complete quality control in every production...
Open the catalog to page 8Safety first, comfort always Our Top line autoclaves are fully automatic, providing maximum comfort and peace of mind in every operation. Effortless push-button door operation With the press of a button, the autoclave door opens and closes automatically, making operation easier and safer while reducing operator strain. This advanced system improves ergonomics, lowers the risk of injury, and increases overall productivity. Bacteriological filter for air inlet and outlet* The bacteriological filter guarantees that all air circulating in and out of the autoclave remains completely sterile, ensuring...
Open the catalog to page 9Our Top line autoclaves are an excellent alternative to floor-standing horizontal autoclaves Floor-standing horizontal autoclaves Often equipped with a fast cooling jacket that uses substantial amounts of water, these units also rely on a central steam boiler that needs to operate non-stop, resulting in a significant environmental footprint due to high fossil fuel consumption. They operate on electricity, are fully selfsufficient, and do not require a central boiler. They consume less water and energy per cycle and comply with strict EU regulations on emissions and energy efficiency. Spatial...
Open the catalog to page 10RAYPACLOUD Comprehensive management of digital quality Top line autoclaves set a new standard of efficiency by incorporating centralized digital quality management and Al-powered predictive maintenance to prevent downtime. Our RAYPAcloud management platform enables secure and centralized management of all autoclave operations, with options for both private and public solutions. Capacitive screen, control over all parameters, real-time program visualization, user control, and access to protocol history. Possibility of integration on Active Directory. Active Directory Advanced technical support....