The equipment shown is representative; its design may be subject to change as part of manufacturing improvements or adjustments. Expert media preparators TLV-MP Series Technical information
Open the catalog to page 1TLV-MP SERIES - DATA SHEET
Open the catalog to page 2Expert culture media preparators General specifications and 200rpm, achieving thorough homogenization of the medium. In addition, its Our expert media preparators from the TLV-MP Series, with dual functionality in the sterilization chamber, generating saturated steam to heat the inner vessel as an autoclave and media preparator, have been designed to optimize the and sterilize the medium. To further optimize the process, there are models with workflow of microbiology and biotechnology laboratories; as well as to cover the enhanced heating capacity to further reduce the duration of the heating...
Open the catalog to page 3Automation of culture media preparation The TLV-MP Series media preparators are engineered to transform the culture The following table presents a detailed comparison between culture media media preparation process by consolidating multiple stages into a single preparation using the conventional autoclave method and our TLV-MP Series device. This integration brings substantial advantages over traditional autoclave media preparators, illustrating the distinct advantages provided by our methods, including reduced preparation time, enhanced reproducibility, and minimized contamination risk, among...
Open the catalog to page 4Benefits of TLV-MP Series media preparators Dual functionality Perfect homogeneity as a media preparator. This dual capability allows for sterilization and media the use of the integrated continuous stirring system, which offers an adjustable preparation processes to be carried out in a single device, eliminating the need speed to meet various needs. Additionally, the automation of the dispensing to purchase separate equipment. As a result, a significant optimization of the phase allows the dispensed volume to be the same in all containers. Our TLV-MP Series media preparators can be used both...
Open the catalog to page 5Expert TLV-MP Series media preparators are available in 4 models: Maximum capacity for preparing culture media L 18 36 54 72 90 Minimum capacity for preparing culture media L 1 5 10 20 20 Inner vessel dimensions 0 x H mm 330 x 236 330 x 461 330 x 696 420 x 594 420 x 734 TLV-MP SERIES - DATA SHEET 6 Other voltages and electrical configurations available on request. Special models with increased power may operate with other voltages. Contact our technical service to receive more information.
Open the catalog to page 6Understanding the operation of expert media preparators Phases of a sterilization cycle A. Pre-vacuum phase* In this initial phase, the cold air in the chamber is mechanically purged to the outside by means of a vacuum pulse, reducing the presence of non-condensable gases and facilitating the transfer of energy from the saturated steam to the load. COOLING TIME B. Heating phase The powerful electric heating elements mounted inside the sterilization chamber heat up rapidly, transferring energy to water to produce saturated steam and heat the inner vessel. C. Sterilization phase When the programmed...
Open the catalog to page 7Preparation Culture media preparation is a fundamental process in microbiology, tissue Speed control by an independent controller culture and biotechnology laboratories. Our expert media preparators are The TLV-MP Series allows precise control of stirring speed via an independent designed to facilitate and optimize this process, combining advanced technology potentiometer located on the control panel, with speeds adjustable up to 200rpm. with ease of use. These devices not only ensure a homogeneous preparation, This feature enables tailoring of the mixing process to the specific requirements...
Open the catalog to page 8Accuracy and flexibility in managing the culture media dispensing phase are critical for safe processes and maximizing productivity. At RAYPA, we understand that each laboratory has unique needs and, therefore, we offer different options for managing the dispensing phase, designed to meet different requirements and production needs: Accessory recommended for automating and accelerating the dispensing phase in repetitive operations involving medium to large volumes. It is the ideal solution for dispensing culture media at high speed when using medium and large media preparators. Overview of dispensing...
Open the catalog to page 9It is the ideal complement for microbiology laboratories that use media preparators and need to perform accurate and safe dispensing in Petri dishes. This system stands out for its ability to execute multiple processes automatically and for its safety measures: the dispensing area is protected by a safety cover and a UV-C lamp that ensures the sterility of the filling area. There are four models available with capacities ranging from 101 to 241 Petri dishes and Compatible with Petri dish data printing systems, such as LINX dispensing volumes ranging from 1mL to 1000mL. 89XX Series printers. Total...
Open the catalog to page 10Automatic cleaning of the dispensing lines One of the most significant challenges when using any media preparator The self-cleaning and disinfection function of the dispensing lines before is dealing with microbial contamination issues and the manual cleaning beginning the sterilization phase is always activated automatically. Therefore, the requirements associated with its use after each rotation. Fortunately for our metal nozzle must be placed inside the bottle provided with the media preparator customers, our media preparators feature an exclusive design that greatly to avoid possible burns...
Open the catalog to page 111. Set the dosing selector to "CLOSED" mode. 2. Check that the dispensing line is not pinched by the peristaltic pump or the external dosing station. 3. Place the metal nozzle of the dispensing line inside the bottle supplied with the media preparator. 1. Set the dosing selector to "CLOSED" mode. 2. Check that the dispensing line is not pinched by the peristaltic pump or the external dosing station. 3. Place the metal nozzle of the dispensing line inside of the supplied bottle. 4. Select the purge option with pressure support. Steps to follow to execute the self-cleaning program of the chamber,...
Open the catalog to page 1219 Pages
102 Pages
9 Pages
10 Pages
10 Pages
12 Pages
16 Pages