1. Catalogs
  2. RAYPA
  3. BENCHTOP AUTOCLAVES WITH DRYING - AHS-DRY SERIES

BENCHTOP AUTOCLAVES WITH DRYING - AHS-DRY SERIES

BENCHTOP AUTOCLAVES WITH DRYING - AHS-DRY SERIES
1 / 20 PagesView full catalog

BENCHTOP AUTOCLAVES WITH DRYING - AHS-DRY SERIES

Product catalog summary
Introduction
The AHS-DRY Series of benchtop autoclaves by RAYPA are designed for efficient laboratory sterilization across various industries. Key features include front-loading access, a drying function, and an independent water tank, optimizing resources like water, power, and time.
Why Choose RAYPA?
  • Global Reach: RAYPA exports 85% of its turnover with distributors in over 100 countries.
  • Expert Manufacturer: Over 45 years of experience in laboratory autoclave manufacturing.
  • Innovation and Quality: Advanced technology and superior construction quality.
  • Efficient Technical Service: Highly qualified technicians provide top-level support.
  • Customizable Range: Offers 11 series and 35 models for various applications.
  • Comprehensive Consultancy: Provides project assessment and training for optimal operation.
Main Features
  • Vacuum Drying: Complete drying of solid loads using a heating jacket and vacuum pump.
  • Construction: High-quality stainless steel (AISI-316L) for corrosion resistance.
  • Control System: PID microprocessor with predefined and editable programs.
  • Safety Features: Overpressure safety valve, thermally insulated door, and safety thermostat.
  • Installation: Plug and play equipment with optional automatic water feed.
Operating Principle
The autoclaves operate through phases: prevacuum, heating, sterilization, vacuum drying, and cooling, controlled by a PID microprocessor for precise management.
Program Modes
The AHS-DRY Series offers 10 programs, with the first four predefined for solids and liquids sterilization. Programs P4 to P9 are editable for temperature, time, and mode adjustments.
Loading Capacities
Different models offer varying capacities, with tables guiding model selection based on load capacities.
Accessories
  • Stainless Steel Components: Tray supports, wire trays, and bag holder supports.
  • Printers: Embedded thermal and external matrix printers for documentation.
  • Temperature Probes: Flexible probes for precise temperature control.
Overview
This document details the AHS-DRY Series benchtop autoclaves, including specifications, accessories, services, and compliance with international standards.
Specifications
Models include AH-21-L, AHS-50-DRY, and AHS-75-DRY, designed for general laboratory use with features like steam generation, vacuum drying, and RS-232 data transfer.
Technical Data
Sterilization chamber volumes range from 22L to 79L, operating at temperatures between 100°C and 134°C, with a maximum pressure of 2.1 Barg. The control system is fully automatic with safety features like a pneumatic door blocking system.
Accessories
Enhancements include a transport trolley, benchtop autoclave table, automatic water filling kit, and more.
Services
Services include consumables, spare parts, maintenance contracts, extended warranty, and training.
Compliance and Safety
Complies with standards such as EN-61010-1, EN-61010-2-040, and others, with safety features ensuring safe operation.
Conclusion
The AHS-DRY Series autoclaves are robust, versatile, and compliant with international standards, suitable for a wide range of laboratory applications.
See more

Catalog excerpts

BENCHTOP AUTOCLAVES WITH DRYING - AHS-DRY SERIES-1

Benchtop autoclaves with drying AHS-DRY Series CLASSIC LINE Technical information

 Open the catalog to page 1
BENCHTOP AUTOCLAVES WITH DRYING - AHS-DRY SERIES-2

AHS-DRY Series Why choose RAYPA? Expert manufacturer, original design, global brand GLOBAL REACH With half a century of experience, we have a long list of satisfied customers around the world. Currently, we export 85% of our annual turnover and have a stable network of distributors with presence in over 100 countries. EXPERT MANUFACTURER After more than 45 years in the industry, RAYPA is a global leader in the manufacture of laboratory autoclaves. Each of our autoclaves is designed and manufactured entirely within our modern facility equipped with the latest technology INNOVATION AND QUALITY...

 Open the catalog to page 2
BENCHTOP AUTOCLAVES WITH DRYING - AHS-DRY SERIES-3

Benchtop autoclaves with drying The AHS-DRY Series benchtop autoclaves with frontloading access cover most laboratory sterilization needs in many industries, educational institutions and research facilities with the aim of increasing the productivity of the laboratory. A great chamber capacity, the final drying feature and the independent water tank, together with the optimization of resources such as water, power and operating time, results in a cost-efficient solution to manage laboratory workload. RECOMMENDED APPLICATIONS Glassware Plastics and metal objects Laboratory waste bags Liquids and...

 Open the catalog to page 3
BENCHTOP AUTOCLAVES WITH DRYING - AHS-DRY SERIES-4

AHS-DRY Series MAIN FEATURES COST-EFFECTIVE SOLUTION EASY INSTALLATION AND MAINTENANCE AHS-DRY Series autoclaves are robust autoclaves with excellent performance for liquids and solids sterilization procedures. The vacuum drying feature by a heating jacket and vacuum pump at the end of the sterilization cycle eliminates the need of an external equipment to dry the load, significantly reducing the duration of each sterilization rotation and saving the operator time. Every AHS-DRY Series autoclave is a plug and play equipment that does not need dedicated installation connections. They simply need...

 Open the catalog to page 4
BENCHTOP AUTOCLAVES WITH DRYING - AHS-DRY SERIES-5

OPERATING PRINCIPLE AHS-DRY Series autoclaves provide a solution for the multiple sterilization needs of general laboratories, including glassware, plastics, metal utensils, laboratory waste bags, wrapped and unwrapped solids, small porous and hollow objects, liquids, culture media and other laboratory items. The load has to be placed into the vessel’s trays or basket and, after manually filling the independent water tank with purified water, the equipment starts to create the initial prevacuum, automatically feeds water to the sterilization chamber, heats up and purges until the set combination...

 Open the catalog to page 5
BENCHTOP AUTOCLAVES WITH DRYING - AHS-DRY SERIES-6

AHS-DRY Series OPERATION OF A STERILIZATION CYCLE FOR SOLIDS PREVACUUM PHASE • In this initial step, the equipment’s vacuum pump mechanically removes air from the chamber and load through a single vacuum pulse of -0,75 Bargs. This allows the steam to penetrate load objects of complex geometries that couldn't otherwise be reached with a simple displacement of the air by gravity. • Afterwards, the independent water tank starts to supply water to the sterilization chamber and the heating jacket turns on, preheating the load. • This crucial step is controlled by a PT-100 Class A temperature probe...

 Open the catalog to page 6
BENCHTOP AUTOCLAVES WITH DRYING - AHS-DRY SERIES-7

Program Sterilization temperature Sterilization time Drying time Program mode AHS-DRY Series autoclaves have 10 programs, from P0 to P9, and the first four are predefined and protected. The rest of the programs, from P4 to P9, can be edited by adjusting the following parameters: • Sterilization temperature. • Sterilization time. • Final drying time. • Sterilization mode (solids or liquids). • Sterilization with temperature holding at the end of the cycle (agar mode). • Temperature regulation of the sterilization cycle can be done through the chamber temperature probe or through the combined use...

 Open the catalog to page 7
BENCHTOP AUTOCLAVES WITH DRYING - AHS-DRY SERIES-8

LOADING CAPACITIES ISO ERLENMEYER FLASKS Usable Total volume baskets Units / basket Total units Units / basket Total units Units / basket Total units Units / basket Total units Usable Total volume baskets Units / basket Total units Units / basket Total units Units / basket Total units Units / basket Total units The data contained within these tables, regarding load capacities, serves as a non-binding guide to assist you in the selection of the most appropriate autoclave model. 8 BENCHTOP AUTOCLAVES WITH DRYING - AHS-DRY SERIES

 Open the catalog to page 8
BENCHTOP AUTOCLAVES WITH DRYING - AHS-DRY SERIES-9

A. Stainless steel tray support for 4 trays*. B. 3 stainless steel wire trays. C. Auxiliary plastic tray for collecting condensed water after opening the door in cycles without final drying. D. Holding clamp to move the trays. E. Silicone tube of 1m with quick connection to drain the independent water tank. F. Stainless steel bag support. Stainless steel protecting grid for the heating elements. A. Stainless steel tray support for 5 trays. B. 2 stainless steel wire trays. C. Auxiliary plastic tray for collecting condensed water after opening the door in cycles without final drying. D. Holding...

 Open the catalog to page 9
BENCHTOP AUTOCLAVES WITH DRYING - AHS-DRY SERIES-10

AHS-DRY Series 10 BENCHTOP AUTOCLAVES WITH DRYING - AHS-DRY SERIES

 Open the catalog to page 10
BENCHTOP AUTOCLAVES WITH DRYING - AHS-DRY SERIES-11

ACCESSORIES STAINLESS STEEL WIRE TRAYS References External dimensions L x D mm Maximum capacity for autoclaves with the following chamber volumes *Special tray support compatible with up to 5 trays available under request. STAINLESS STEEL WIRE HORIZONTAL BASKET References Dimensions Maximum capacity for autoclaves with the following chamber volumes STAINLESS STEEL BAG HOLDER SUPPORT* References External dimensions L x D x H mm Positions / support Maximum capacity for autoclaves with the following chamber volumes *Possibility of adapting the size of this accessory according to the needs of each...

 Open the catalog to page 11
BENCHTOP AUTOCLAVES WITH DRYING - AHS-DRY SERIES-12

AHS-DRY Series FLEXIBLE TEMPERATURE PROBE PT-100 CLASS A After installing this accessory, the temperature regulation of the sterilization cycle can be controlled by the main chamber temperature probe or both the main chamber temperature probe and the flexible temperature probe. The temperature control by the flexible temperature probe is especially advantageous for processes involving the sterilization of large volumes of liquids, where the sterilization process is regulated by both the temperature achieved in the center of the liquid sample as well as the temperature achieved in the sterilization...

 Open the catalog to page 12
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.