Lightning & Surge Protection for Wind Turbine Systems Product Selection Guide

Open the catalog to page 1
Lightning & Surge Protection for Wind Turbine Systems - 2

Table of Contents Technologies for Wind Turbine Protection Protective Device Recommendations Class I Strikesorb Surge Protection Solutions Class I SafeBloc for Wind Turbines Class I DIN Rail Protection Solutions Class II DIN Rail Protection Solutions Class III DIN Rail DC Protection Solution Signal & Data Protection Technologies Lightning Protection Zones

Open the catalog to page 2
Lightning & Surge Protection for Wind Turbine Systems - 3

Raycap offers the wind industry a variety of Surge Protective Device (SPD) technologies for the protection of wind turbines. Our solutions are ideally suited for these often remote and mission critical installations. The technologies included in the products we recommend include: Strikesorb Raycap's premium protection technology carries a 10 year warranty. This patented technology is uniquely equipped to safeguard against lightning surges, and has been engineered and tested for use in wind power applications. Strikesorb is maintenance free, due to its unparalleled ability to take multiple...

Open the catalog to page 3
Lightning & Surge Protection for Wind Turbine Systems - 4

Protected Area 1 Transformer 2 Mains Entrance and Converter 3 Control Cabinet in the Tower Base 4 Generator 5 Control Cabinet in the Nacelle 6 Aviation Lights 7 Environmental Measurement Systems 8 Pitch Control & Anti-/De-icing 9 Condition Monitoring Power Lines Superior Advantaged Basic DC & Data / Signals SafeBloc B ProTec T1 SafeBloc B ProTec T1 ProTec T2 ProTec T2 ProTec DMDR RayDat SBH/SLH RayDat NET 6 POE ProTec T1 ProTec T2 ProTec DMDR RayDat SBH/SLH RayDat NET 6 POE ProTec T2 ProTec DMDR RayDat SBH/SLH ProTec T2 RayDat SBH/SLH

Open the catalog to page 4
Lightning & Surge Protection for Wind Turbine Systems - 5

Protective Devices for Wind Power Systems Power Line Signal Line Down Conductor Raycap Product Selectio

Open the catalog to page 5
Lightning & Surge Protection for Wind Turbine Systems - 6

Surge Protection Solutions for Wind Turbine Systems Strikesorb® 80 Class I LIGHTNING & SURGE PROTECTION FOR WIND TURBINE SYSTEMS

Open the catalog to page 6
Lightning & Surge Protection for Wind Turbine Systems - 7

Surge Protection Solutions for Wind Turbine Systems Enhanced Strikesorb 30 Class I + II IEC/ EN / UL Category: Protective Elements: Surge Ratings Compliance: Class I + II / Type 1+2 / Type 2 CA High Energy MOV Ilmp = 7.5 kA (10/350 |js) Imax = 60 kA (8/20 js) UL 1449 4th Edition IEC 61643-11: 2011 EN 61643-11:2012 IEEE C62.11: 2012 IEEE C62.41.2: 2002 IEEE C62.45: 2002 C€cTOus^> Enhanced Strikesorb 30 Electrical Maximum Continuous Operating Voltage (AC) Nominal Discharge Current per UL 1449 4th Edition (8/20 js) Maximum Surge Current Capacity (8/20 js) Impulse Discharge Current (10/350...

Open the catalog to page 7
Lightning & Surge Protection for Wind Turbine Systems - 8

Pluggable Multi-Pole SPD ProTec T1 2+0 Class I + II Location of Use: Network Systems: Mode of Protection: Surge Ratings: IEC/EN/UL Category: Protective Elements: Housing: Compliance: Main Distribution Boards TN-S L-PE, N-PE Ilmp = up to 12.5 kA (10/350 ps) Imax = 50 kA (8/20 ps) Class I + II / Type 1+2 / Type 1CA High Energy MOV Pluggable Design IEC 61643-11:2011 EN 61643-11:2012 UL 1449 4th Edition ProTec T1-xxx-2+0(-R) IEC Electrical Maximum Continuous Operating Voltage (AC) Nominal Discharge Current (8/20 ps) Maximum Discharge Current (8/20 ps) Impulse Discharge Current (10/350...

Open the catalog to page 8
Lightning & Surge Protection for Wind Turbine Systems - 9

Pluggable Multi-Pole SPD SafeTec T2 3+0 Class II Location of Use: Network Systems: Mode of Protection: Surge Ratings: IEC/EN/UL Category: Protective Elements: Safety: Housing: Compliance: Sub-distribution Boards TN-C L-PEN Imax = up to 50 kA (8/20 ps) Class II / Type 2 / Type 1CA High Energy MOV and GDT Patented Current Limiting Technology Pluggable Design IEC 61643-11:2011 EN 61643-11:2012 UL 1449 4th Edition C€cTOus<^> SafeTec T2-xxx-3+0(-R) IEC Electrical Maximum Continuous Operating Voltage (AC) Nominal Discharge Current (8/20 ps) Maximum Discharge Current (8/20 ps) Voltage Protection...

Open the catalog to page 9
Lightning & Surge Protection for Wind Turbine Systems - 10

Location of Use: Network Systems: Mode of Protection: Surge Ratings: IEC/EN/UL Category: Protective Elements: Housing: Compliance: Sub-Distribution Boards TN-C L-PEN Imax= 50 kA (8/20 ps) Class II / Type 2 / Type 1CA High Energy MOV Pluggable Design IEC 61643-11:2011 EN 61643-11:2012 UL 1449 4th Edition ProTec T2-ADV-xxx-3+0(-R) IEC Electrical Maximum Continuous Operating Voltage (AC) Nominal Discharge Current (8/20 ps) Maximum Discharge Current (8/20 ps) Voltage Protection Level Back-Up Fuse (max) Short-Circuit Current Rating (AC) TOV Withstand 5s Order Information Order Code ProTec...

Open the catalog to page 10
Lightning & Surge Protection for Wind Turbine Systems - 11

Location of Use: Network Systems: Mode of Protection: Surge Ratings: IEC/EN/UL Category: Protective Elements: Housing: Compliance: Sub-Distribution Boards TN-S L-PE, N-PE Imax = 50 kA (8/20 ps) Class II / Type 2 / Type 1CA High Energy MOV Pluggable Design IEC 61643-11:2011 EN 61643-11:2012 UL 1449 4th Edition C€cTCus<i> ProTec T2-xxx-2+0(-R) IEC Electrical Maximum Continuous Operating Voltage (AC) Nominal Discharge Current (8/20 ps) Maximum Discharge Current (8/20 ps) Voltage Protection Level Back-Up Fuse (max) Short-Circuit Current Rating (AC) TOV Withstand 5s Order Information Order...

Open the catalog to page 11
Lightning & Surge Protection for Wind Turbine Systems - 12

DC Modular Multi-pole SPD ProTec DMDR 20 Series Class III Location of Use: Sub-distribution Boards Network Systems: TN-S Mode of Protection: L - PE, N - PE, L - N Surge Ratings: Uoc /Icw = up to 6 kV/3 kA Imax = up to 4 kA (8/20 |js) IEC/EN Category: Class III / Type 3 Protective Elements: High Energy MOV and GDT Housing: Modular Design Compliance: IEC 61643-11:2011 EN 61643-11:2012 Electrical Maximum Continuous Operating Voltage (AC/DC) Uc 24 V / 34V 48 V/60V 60V/75V 120V/150 V Open Circuit Voltage of the Combination Wave Generator (1.2/50...

Open the catalog to page 12
Lightning & Surge Protection for Wind Turbine Systems - 13

Modular SPD for Industrial Fieldbus Systems IEC/EN Category: Mode of Protection: Coarse Protection: Frequency Range: Surge Discharge Ratings: Series Load Current: Enclosure: Terminals: Housing: Compliance: SBH-3 Series Electrical Nominal Operating Voltage (DC) Maximum Continuous Operating Voltage (DC) Rated Load Current at 25°C C2 Nominal Discharge Current (8/20 ps) Maximum Discharge Current (8/20 ps) D1 Impulse Current (10/350 ps) Residual Voltage at 5 kA (8/20 ps) Order Information SBH-3-xx SBH-3-xx Q (Quick Connect Terminals) IEC/EN Category: Mode of Protection: Coarse...

Open the catalog to page 13