Main Performances
The PME Evolution slipring features an aluminium housing with insulating thermoplastic bands. It is designed for vertical axis positioning and is mounted on a base plate using two M10 screws. Connections are made via rings wired with a 2-meter long cable, and cable entry is facilitated through single-pole wires connected to the rings and pipe unions M32 to the brush-holders. The brushes are available in copper-graphite with current ratings of 20 A, 50 A, and 100 A. The slipring can be configured with 20 to 60 rings at 20 A, with mixed executions of 20/50/100 A.

Standards and Marking
The product complies with CEI-EN 60947-1 and CEI-EN 60529 standards, as well as directives 2014/35/UE, 2014/30/UE, and 2006/42/CE. It carries the CE marking.

Accessories
Optional accessories include Mercotac, Absolute Encoder, Micro-switches application, and one passage for air. Mixed executions with 100 A, 50 A, and 20 A, as well as types with appropriate rings for signals, are available on demand.

Functional Features
The slipring operates at a nominal voltage of 660 V AC/DC and nominal currents of 20 A, 50 A, and 100 A. It has a protection degree of IP65 and a maximum rotating speed of 30 revolutions per minute. The test voltage is 2.5 kV, and it operates within a temperature range of -20 °C to +60 °C.

Installation and Wiring
Installation must be performed by qualified personnel following safety standards. Power should be turned off before wiring, and connections should comply with the equipment's wiring scheme. The base plate uses fork fastons with an interaxis of 260 mm and M10 screws. Cables are connected through lateral pipe unions, with specified torque for brush terminals. Ensure wires do not interfere with moving parts, and check equipotential and ground connections.

Maintenance
Regular maintenance is required to keep the slipring in optimal condition. Maintenance should be performed by qualified personnel using original spare parts. Key steps include disconnecting from the power source, checking brushes for wear, removing copper-graphite dust, and ensuring cable tightness and gasket condition. The guarantee does not cover modified or tampered equipment.

Dimensions
The slipring dimensions vary based on the number of rings, with specific measurements provided for types ranging from 20 to 60 rings. Installation requires specific plate and pivot configurations to ensure proper rotation and function.
See more

Catalog excerpts

PME evolution-1

Technical Sheet Housing Positioning Connections Cable entry Brushes Executions Armonized rules Marking In aluminium with insulating thermoplastic bands Vertical axis, assembly on the base plate by means of 2 screws M10 Rings wired with 2 m. long cable With single-pole wires connected to the rings and through pipe unions M32 to the brush-holders 20 A, 50 A and 100 A in copper-graphite From 20 to 60 rings 20 A - mixed executions 20/50/100 A CEI-EN 60947-1 CEI-EN 60529 2014/35/UE-2014/30/UE-2006/42/CE Directives CE Functional Features Nominal voltage Nominal current Protection degree Max rotating speed Test voltage Operating temperature Standard Types Type 20A N° Rings H = mm* Availability on demand: • Mixed executions with 100 A, 50 A and 20 A • Types with appropriate rings for signals Accessories Availability on demand: • Mercotac • Absolute Encoder • Micro-switches application • One passage for air Ravioli S.p.A. Via Passo Pordoi, 4 - 20139 Milano Tel. +39 02 53.63.01 - Fax +39 02 53.63.05 E-mail: [email protected] - www.raviolispa.com

 Open the catalog to page 1
PME evolution-2

The PME Evolution slipring has to be installed only by qualified personnel in compliance with current safety standards. Power to the machine must be turned off before carrying out wiring. Connections are to be made in compliance with the wiring scheme of the controlled equipment. After installation has been completed, the installer is required to check that all commands are working properly. Avoid prolonged contact with oils and acids when using the equipment, as these may Thedamage the products. to be installed only by qualified personnel in A programme of periodical maintenance is required...

 Open the catalog to page 2

All Ravioli spa catalogs and technical brochures

  1. EXD

    2  Pages

  2. Roller KOMBI

    1  Page

  3. Roller

    2  Pages

  4. PRG

    1  Page

  5. PRP

    2  Pages

  6. PMP

    2  Pages

  7. PMS

    2  Pages

  8. PME

    6  Pages

  9. Dual

    2  Pages

  10. Jump - J Line

    2  Pages

  11. FCN

    6  Pages

  12. PRM

    6  Pages

  13. PSP

    6  Pages

  14. PMT

    6  Pages

  15. Stilo

    6  Pages

  16. Lady

    8  Pages

  17. FRM

    8  Pages

  18. FRS

    2  Pages

  19. Compact

    6  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.