Catalog excerpts
Typ : RWS-Ex-RPW-2100-Exi (ATEX) For weighing system types: RAVAS-2100 EXi – RAVAS-2100L EXi – ProLine 2100 EXi Weighing handpallet trucks Even full stainless steel versions are available
Open the catalog to page 1Symbols Safety instructions Conformity to standards Function Technical data Arrangement Opening and closing of the enclosure Commissioning Maintenance and servicing Accessories and spare parts Transportation and storage Disposal Functions indicator 13.1 Touch panel indicator 13.2 Functions indicator 13.2.1. Multirange 13.2.2. Before weighing: zero check 13.2.3. Gross weighing 13.2.4. Net weighing: automatic tare 13.2.5. Net weighing: manual tare-entry 13.2.6. Totalizing 13.2.7. Printing (optional) APPENDIX EC-Declaration of conformity EC-Type examination certificate DEKRA 13ATEX0044...
Open the catalog to page 2Warning! This symbol indicates advice which, if ignored, puts your health or the ability of the device or devices to function at risk. Note: This symbol indicates important additional information, tips and recommendations. 2 Safety instructions The most important safety instructions are summarised in this chapter. It is intended to supplement the relevant regulations which must be studied by the personnel responsible. When working in hazardous areas, the safety of personnel and plant depends on complying with all relevant safety regulations. Assembly and maintenance staff working on...
Open the catalog to page 34 Function This operating manual describes the following device: - Palettrucks with weighing system RWS-Ex-RPW-2100-Exi For functionality indicator, see manual (page 9) 5 Technical data Please consult the manufacturer if operating conditions are non-standard. Additional technical data can be obtained upon request. 5.1 Ex protection RWS-Ex-RPW-2100-Exi EG-type researchccertificate: Explosion protection, device group and category May be used in temperature range: Tabel 5-1: Ex protection data 5.2 Electrical data Supply by battery type BU-2100-Exi (certificate DEKRA 13ATEX0043) The battery may...
Open the catalog to page 4Before commissioning, ensure that the device is not damaged. The power supply to the system takes place through an exchangeable battery pack. With a completely charged battery pack the total weighing time is about 100 hours When the voltage level of the battery is running low, the display will show “LO-BA“. When the battery is completely empty, the weighing system switches off. When charging, it is necessary to charge the battery for at least 6 hours. This will prevent loss of battery capacity. If you use the system in shift work, it is recommended to purchase a supplementary battery pack....
Open the catalog to page 5- Degree of wind, rain and sunlight exposure • The operating conditions: - Duty cycle of the system - Operator errors • Manufacturer information in the technical documentation: - Mechanical and electrical service life 9.2 Inspection content Perform the inspections as determined by the local requirements. The inspections include visual examinations, general checks and detailed inspections. If defects which affect explosion protection are discovered during inspections, then the equipment is to be taken out of service until the defect is remedied. .
Open the catalog to page 610 Accessories and spare parts Use only original accessories and spare parts from electromach b.v.. Use of another company’s accessories and spare parts invalidates the warranty of electromach b.v.. 11 Transportation and storage Transport and storage are only permissible in the original packaging. 12 Disposal Please observe the national waste-disposal regulations. Should you require the operating instructions in one of the other European Community languages, please feel free to contact your electromach representative.
Open the catalog to page 813 INDICATOR MANUAL 13.1 TOUCHSCREEN DISPLAY Frontview indicator THE DISPLAY The 3 bars in the display indicate: ◄ ▬ NET The weighing system (including load) is stable The display weight is negative The display shows the net weight DISPLAY MESSAGES The ‘’-‘’ sign in the display occurs. The display might show one of the following messsages: HELP 1 The weighing system is in overload. A negative weight will be tared. There is a negative sign from the loadindicator on the AD converter / the system is not level. (Manually) the entered tare weight is to high. Push the PT button again to erase...
Open the catalog to page 9The Touch panel Each key has a company- or entering function. Company function Entering function Zero setting and automatic tare Confirm and segment left Tare entry Lower value of the flashing segment Raise value of the flashing segment IMPORTANT Pushing a key will only be accepted when the system is stable ( and the sign ‘’load stable’’ flashes). This means that al functions will only be performed when the weight is stable. WARNING If the weighed load is higher then the maximum, the sign: ‘’HELP1” shows. To prevent damage to the indicator or the loadcells, the load has to be removed as...
Open the catalog to page 1013.2 INDICATOR OPTIONS 13.2.1. MULTIRANGE The graduation of the indicator depends on the weighed load: from 0 till 200 kg the weight will be displayed in 0,2 kg graduation steps; from 200 till 500 kg will be displayed in 0,5 kg gradation steps; from 500 till 2000 kg the weight will be displayed in 1 kg. steps. Because of the weight dependable graduation smaller weights will be weighed with an increased accuracy. After taring the weight, smaller weights can be totalized or deducted with the graduation which belongs to the smaller weight. If the weight changes the graduation also...
Open the catalog to page 11Push value up or down until the flashing segment has the wished value. Push the ENTER () button for adjusting the next segment. Repeat these actions until the requested tare weight is shown on the display. If you want to activate the tare weight but not save is, push the ENTER () button for 3 seconds to confirm the value. Tare weight is activated. The bar “NET” shows. If the system is loaded, the net weight shows on the display. If the system is unloaded, the display shows the entered tare weight as a negative. If the system is unloaded, the display shows the Net weight in...
Open the catalog to page 12All RAVAS USA catalogs and technical brochures
-
ProLine 5200-Li
2 Pages
-
ProLine Touch Basic
48 Pages
-
RAVAS-500 Series
36 Pages
-
RAVAS-100 Series
24 Pages
-
iFORKS-32 XT
2 Pages
-
RPW EL
2 Pages
-
INDICATOR 610
2 Pages
-
iFORKS Economy 2.0
2 Pages
-
RCS Hy-Q-52
2 Pages
-
PRINTERS
3 Pages
-
iFORKS-32
2 Pages
-
UniMobile
2 Pages
-
iFORKS XT
2 Pages
-
RAVAS PROLINE 310
2 Pages
-
RAVAS-610L
2 Pages
-
RAVAS-1
2 Pages
-
RPW EL
2 Pages
-
RVL
2 Pages
-
iFORKS TOUCH
2 Pages
-
RAVAS-4100L
1 Pages
-
RAVAS-310L
1 Pages
-
INDICATOR 2100
1 Pages
-
INDICATOR 6100
1 Pages
-
CUBETAPE
2 Pages
-
MFORKS
2 Pages
-
UniMobile Connect
1 Pages
-
Indicators
1 Pages
-
Stacker truck: RPW-ST
1 Pages
-
Forklift truck scales RCS
1 Pages
-
RAVAS-110
1 Pages
-
RCS-110-PLUS
2 Pages
-
iForks
2 Pages
Archived catalogs
-
Pallet truck scales RAVAS-1
2 Pages