Catalog excerpts
MOBILE WEIGHING Operation Manual ProLine Touch Basic Weighing Terminal For Hand Pallet Truck We would like to inform you about the fact that this RAVAS product is 100 % recyclable on the basis that the parts are processed and disposed off in the right manner. More information can be found on our website www.ravas.com. Rev.20211122 Printing/typographical errors and model changes reserved © RAVAS Europe B.V. • Veilingweg 17 • NL 5301 KM Zaltbommel • Tel.: +31 (0)418 - 515220 • E-mail: info@ravas.com • Internet: www.r
Open the catalog to page 1Operation Manual RAVAS Proline Touch Basic Rev. 6 Operation Manual Proline Touch Basic Published By: RAVAS Europe b.v., Veilingweg 17, NL 5301 KM Zaltbommel All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, mechanical, photocopying, recording, or otherwise, without the prior written permission of RAVAS Europe b.v. © RAVAS Europe b.v. Words which we have reason to believe constitute registered trademarks are designated as such. However, neither the presence nor the absence of such designation should...
Open the catalog to page 2Operation Manual RAVAS Proline Touch Basic Rev. 6
Open the catalog to page 3Operation Manual RAVAS Proline Touch Basic Rev. 6 The Weighing Hand Pallet Truck 1.1.1 After approx. 3 to 5 minutes the electronics and the loadcells have reached their operating temperature. Before that deviations of up to 0.3% may occur. Please set display to zero before weighing loads. A fully charged battery provides power for approx. 10 hours of uninterrupted operation. To avoid damages to the battery it should never be completely discharged. Deep discharge strongly reduces the life time of the battery. Charging at regular intervals ensures full operational availability. Charger: When...
Open the catalog to page 5Operation Manual RAVAS Proline Touch Basic Rev. 6 The load must be lifted freely without touching the housing of the indicator or other objects. Incorrect lifting of load Correct lifting of load When operated on a non-even, sloped surface the accuracy of the scale is reduced by 0.1% for every 2° of inclination. This effect is also caused by holes in the floor. For best weighing results use scale on flat and even level surface. The best weighing result is obtained when the center of gravity of the load lies between the forks. Excentric load may lead to bending and twisting of the forks, and...
Open the catalog to page 6Operation Manual RAVAS Proline Touch Basic Rev. 6 • Check oil level at 6-month intervals.
Open the catalog to page 7Operation Manual RAVAS Proline Touch Basic Rev. 6 Weighing Terminal This manual describes the basic functions and the operation of the Proline Touch weighing terminal with the operator interaction in the individual steps of the operating sequence. The terminal is intended for connection to 12 V DC power supply (–15%) to 30VDC (+10%). The weighing terminal supports power saving functions for battery operation: • Power off for display backlighting after time; Power off for terminal when not in use after time; Power off on battery low after warning. Apart from this documentation, additional...
Open the catalog to page 8Operation Manual RAVAS Proline Touch Basic Rev. 6 Weight Display And Scale Function Keys Electronic marking plate Scale-No. / weighing range Charge state (battery operation) Weight display Scale function keys Scale no-motion symbol Auxiliary display Please note that 'key' refers to the corresponding sensor field of the currently displayed template, in the same way 'pressing a key' is to be understood as touching the respective field of the touch panel. Scale Function Keys Call up Service Mode; to access the Service Mode, touch the field of the weight display (2 sec min.) Set Zero Key to set...
Open the catalog to page 9Operation Manual RAVAS Proline Touch Basic Rev. 6 partial weighing range for multiple-range scales. No-Motion Symbol Settled weight (printing / storing enabled). Gross Weight Or Net Weight Switching from gross weight to net weight with Tare-key. Weight unit, selectable in calibration mode. Auxiliary Display (switchable via Display Select Key) Tare Display of tare weight Display of gross weight Gross weight bargraph (zero to max load) Approved weight storage Firmware information W&M approved data archive (see chapter 'Data Archive') Show details of firmware version Example for firmware...
Open the catalog to page 10Operation Manual RAVAS Proline Touch Basic Rev. 6 With the '123...' key the layout can be switched back to the template for numeric inputs.
Open the catalog to page 11Operation Manual RAVAS Proline Touch Basic Rev. 6 Operation Of Scale Functions Preset Tare (PT) After pressing the PT-key, the template for numeric inputs is opened and a tare value can be entered and confirmed with the Enter-key. Display of net weight in the main display and of tare weight in the auxiliary display. By pressing the Tare-key the tare is cleared and the main display returns to the indication of the gross weight. Tare Balancing By pressing the Tare-key, tare balancing (autotare) is executed. By pressing the Tare-key once more the display returns to gross weight.
Open the catalog to page 12Operation Manual RAVAS Proline Touch Basic Rev. 6 Operation Via Display And Keyboard After switching the terminal on, automatically the power up messages are displayed, then the program proceeds to the template 'main menu'. Power up messages and program version.
Open the catalog to page 13Operation Manual RAVAS Proline Touch Basic Rev. 6 Main Menu Weighing mode Counting mode Load / Unload Totalizing Recipe Weighing Gravity Determination Data Input Operating mode loading / unloading Summing mode Recipe weighing mode Operating mode determination of center of load. Note: Must be enabled in menu 'Gravity parameters'. Entry of data Choose operating mode.
Open the catalog to page 14Operation Manual RAVAS Proline Touch Basic Rev. 6 Special Functions For Mobile Weighing The weighing terminal features a power save mode and remains in sleep mode when external power is on. To switch the terminal on press Power off on battery low If the input voltage falls below 11.3 V a blinking 'Battery Low' signal is shown. If no key is pressed within the next 2 min after the signal started blinking, the terminal is switched off. With every key stroke timeout is reset to 2 min. The terminal can be switched on again by pressing timeout period of 2 min is started anew. The further power...
Open the catalog to page 15All RAVAS USA catalogs and technical brochures
-
ProLine 5200-Li
2 Pages
-
Weighing handpallet trucks
21 Pages
-
RAVAS-500 Series
36 Pages
-
RAVAS-100 Series
24 Pages
-
iFORKS-32 XT
2 Pages
-
RPW EL
2 Pages
-
INDICATOR 610
2 Pages
-
iFORKS Economy 2.0
2 Pages
-
RCS Hy-Q-52
2 Pages
-
PRINTERS
3 Pages
-
iFORKS-32
2 Pages
-
UniMobile
2 Pages
-
iFORKS XT
2 Pages
-
RAVAS PROLINE 310
2 Pages
-
RAVAS-610L
2 Pages
-
RAVAS-1
2 Pages
-
RPW EL
2 Pages
-
RVL
2 Pages
-
iFORKS TOUCH
2 Pages
-
RAVAS-4100L
1 Pages
-
RAVAS-310L
1 Pages
-
INDICATOR 2100
1 Pages
-
INDICATOR 6100
1 Pages
-
CUBETAPE
2 Pages
-
MFORKS
2 Pages
-
UniMobile Connect
1 Pages
-
Indicators
1 Pages
-
Stacker truck: RPW-ST
1 Pages
-
Forklift truck scales RCS
1 Pages
-
RAVAS-110
1 Pages
-
RCS-110-PLUS
2 Pages
-
iForks
2 Pages
Archived catalogs
-
Pallet truck scales RAVAS-1
2 Pages