1. Catalogs
  2. RATTIINOX SRL
  3. GENERAL CATALOGUE

GENERAL CATALOGUE

GENERAL  CATALOGUE
1 / 132 PagesView full catalog

GENERAL CATALOGUE

Product catalog summary
Overview: Rattiinox specializes in engineering, construction, and supply of custom solutions and special products for aseptic systems, serving pharmaceutical, chemical, and alimentary sectors with over 40 years of experience in stainless steel machining.
Key Sections:
  • Aseptic Sampling Valves: Designed for sterile sampling in pharmaceutical applications, featuring materials like PTFE and AISI 316L.
  • Aseptic Diaphragm Valves: Suitable for biotechnology, semiconductor, pharmaceutical, food, and medical processes, fully autoclavable.
  • Check Valves and Tri-Clamp Fittings: Designed for high-pressure applications, ensuring secure connections in aseptic environments.
  • Needle Valves: For precise control of fluid flow in high purity applications.
  • Special Components: Custom components for specific applications, compatible with aseptic systems.
Technical Specifications: Detailed specifications include material composition, size dimensions, and maximum working conditions. Products meet FDA and USP standards with various diaphragm materials and installation recommendations.
Documentation and Compliance: Products include laser marking for traceability, material certificates, and compliance with standards like ASTM A270 and ASME-BPE. Atex validation available upon request.
Specifications: Valves made from AISI 316L stainless steel, with O-Rings in FPM/FKM, EPDM, SILICONE FDA, or SILICONE USP 121. Designs include ASTM A270 Tri-Clamp, DIN 32676 Tri-Clamp, and ISO 1127 Tri-Clamp. Internal finishing is Ra ≤ 0.4 μm, external finishing is Ra ≤ 0.8 μm, mirror polished. Maximum working conditions are 12 bar (170 psi) and 150°C (300°F).
Installation Guidelines: Ensure correct flow direction during assembly. Horizontal installation is recommended for optimal performance.
Valve Types and Codes: Inline 30° O-Ring Sampling Valves, Inline 180° Needle Sampling Valves, and Side Sampling Valves with various configurations.
Spare Parts: Includes body, piston, O-Rings, rings, grub screws, and handles with specific material details.
Key Recommendations: Use the correct O-Ring material based on application requirements. Follow installation guidelines for proper valve function and longevity.
Standards and Compliance: Designs comply with ASTM A270, ASME-BPE, DIN 32676, and ISO 1127 standards. Documentation includes laser marking for traceability and validation, material certificates, and surface finishing checks.
Tri-Clamp Fittings and Components: Designed for sterile process engineering, using materials like AISI 304 and AISI 316 stainless steel. Components conform to standards such as DIN 32676, ISO 1127, and ASTM A270.
Procedures and Recommendations: Emphasizes high-quality CNC machining technologies and ultrasonic cleaning for maintaining high purity standards.
Applications: Suitable for adapting pressure and temperature measuring instruments to pipelines, reducing dead legs, and developed for sterile process engineering applications.
General Sales Conditions: Customers must report damage upon delivery with photographic evidence. Claims must be made within eight days. Returns require prior authorization. Legal disputes handled by the Court of Milan. Goods remain property of the producer until full payment.
Privacy Protection: Personal information used for administrative and legal purposes, in compliance with Italian privacy laws.
Copyright Notice: Reproduction of the catalog is prohibited without permission. Rattiinox reserves the right to modify the catalog without notice.
Company Information: Rattiinox s.r.l. is located in Mariano Comense, Italy, with contact details provided.
See more

Catalog excerpts

GENERAL  CATALOGUE-1

RATTIINOX ASEPTIC EQUIPMENT -DESIGN & SUPPLIER

 Open the catalog to page 1
GENERAL  CATALOGUE-2

Engineering, construction and supply of special product and custom solutions. Rattiinox aims to satisfy the customer by providing a mix of custom products and services geared towards high quality production, in full respect of the aseptic systems and regulations.

 Open the catalog to page 2
GENERAL  CATALOGUE-3

More than 40 years of experience in the stainless steel machining has made of Rattiinox a successful firm in the supplying of components for pharmaceutical, chemical and alimentary installations. Modern management of Rattiinox is orientated towards delivering services and products able to satisfy Customers requirements as concern aseptic processes and high purity technologies by designing with dedicated equipment, devices and systems. Rattiinox aims to satisfy the customer by providing a mix of products and services geared towards high quality production, in full respect of the aseptic systems...

 Open the catalog to page 3
GENERAL  CATALOGUE-4

ASEPTIC ASEPTIC INLINE SIDE DIAPHRAGM SAMPLING SAMPLING SAMPLING VALVES VALVES VALVES VALVES ART. 061 P. 005 Disc Aseptic Diaphragm Valves ART. 046 P. 011 Compact Aseptic Sampling Valves ART. 057 P. 020 Inline 180° O-Ring Sampling Valves ART. 058 P. 022 Inline 30° O-Ring Sampling Valves ART. 037 P. 031 Inline 180° Needle Sampling Valves ART. 044 P. 034 90° O-Ring Sampling Valves ART. 045 P. 042 180° O-Ring Sampling Valves ART. 090 P. 044 30° O-Ring Sampling Valves ART. 091 P. 052 Ingold O-Ring Sampling Valves ART. 023 P. 054 90° Needle Sampling Valves ART. 022 P. 055 90°...

 Open the catalog to page 4
GENERAL  CATALOGUE-5

ART. 049 P. 062 Needle Valves ART. 053 P. 068 Needle Valves Gas Threaded ART. 054 P. 069 Gauge Holder Gas Threaded ART. 048 P. 072 Check Valves ART. 001 P. 074 Check Valves Gas Threaded ART. 002 P. 076 Adjustable Check Valves Gas Threaded ART. 110 P. 080 Tri-Clamp Ferrule 1.4435 ART. 115 P. 082 Tri-Clamp Ferrule 1.4404 ART. 085 P. 086 Mini Tri-Clamp ART. 120 P. 087 Solid end Cap 1.4435 ART. 125 P. 088 Solid end Cap 1.4404 ART. 030 P. 089 Tri-Clamp Tee ART. 031 P. 089 Tri-Clamp Elbow ART. 028 P. 090 Hose Barb ART. 040 P. 092 Tri-Clamp Reducer ART. 026 P. 096 Tri-Clamp Male Adaptor ART. 027 P....

 Open the catalog to page 5
GENERAL  CATALOGUE-6

The state of the art without asymptotic seal, born for Aseptic and High Purity Applications ASEPTIC DIAPHRAGM VALVES

 Open the catalog to page 6
GENERAL  CATALOGUE-7

=$>RATTIINOX ASEPTIC EQUIPMENT - DESIGN & SUPPLIER 06 ASEPTIC DIAPHRAGM VALVES Characteristics: Engineered and patented aseptic valves for biotechnology and semiconductor industries, pharmaceutical, food and medical processes. Designed for Aseptic and High Purity Applications. Two material: PTFE and AISI 316 L without asymptotic seals. Innovative internal design with inclined contact surfaces to drain the fluid. Fully autoclavable. Documentation: Laser marking for traceability and validation processes. Material 3.1 certificates, FDA or USP, internal surface finishing check as standard. Atex validated...

 Open the catalog to page 7
GENERAL  CATALOGUE-8

Disc Aseptic Diaphragm Valves =$>RATTIINOX ASEPTIC EQUIPMENT - DESIGN & SUPPLIER ASEPTIC DIAPHRAGM VALVES ASTM A270 Tri-Clamp Size Int. finishing: Ra < 0,4 pm Ext. finishing: Ra < 0,8 pm Mirror Polished Max Working Conditions: 10 bar (150 psi) and 150°C (300°F) Gaskets: USP CLASS VI - 70° PTFE or USP CLASS VI - 121° PTFE or GUAFLON Installation: Horizontal installation recommended

 Open the catalog to page 8
GENERAL  CATALOGUE-9

ASEPTIC DIAPHRAGM VALVES Disc Aseptic Diaphragm ValvesSPARE PARTS =@RATTIINOX ASEPTIC EQUIPMENT -DESIGN & SUPPLIER 6 Special Screw AISI 304 PTFE + AISI 316L 7 Diaphragm or GUAFLON 8 O-Ring FPM/FKM 9 Special Washer AISI 304

 Open the catalog to page 9
GENERAL  CATALOGUE-10

Disc Aseptic Diaphragm Valves =$>RATTIINOX ASEPTIC EQUIPMENT - DESIGN & SUPPLIER ASEPTIC DIAPHRAGM VALVES ASTM A270 Tri-Clamp Size Int. finishing: Ra < 0,4 pm Ext. finishing: Ra < 0,8 pm Mirror Polished Max Working Conditions: 10 bar (150 psi) and 150°C (300°F) Installation: Vertical installation recommended Spare parts N° Name Material Cover with 2 adjustable AISI 316L 6 Special Screw AISI 304

 Open the catalog to page 10
GENERAL  CATALOGUE-11

Disc Aseptic Diaphragm Valves =@RATTIINOX ASEPTIC EQUIPMENT -DESIGN & SUPPLIER ASEPTIC DIAPHRAGM VALVES The opening and closing movements do not detect the areas which are away from the shutter's contact surface, which however, is inclined and it allows the draining of the fluid outwards during the support movement and the tightness of the diaphragm on the work table shutting surface (1). The internal chute allows the valve's chamber to easily empty itself even during horizontal use (2). The inverse taper of the tightness surface in correlation with the diaphragm's surface sustain allows for...

 Open the catalog to page 11
GENERAL  CATALOGUE-12

Maximum accuracy for a rapresentative Aseptic sampling ASEPTIC SAMPLING VALVES

 Open the catalog to page 12
GENERAL  CATALOGUE-13

ASEPTIC SAMPLING VALVES COMPACT ASEPTIC SAMPLING VALVES Characteristics: Designed for sterile sampling of liquids on pharmaceutical products. Radial diaphragm with extremely compact design. Diaphragm closes at the inlet seat of the product port connection, eliminating the dead leg. Engineered for Aseptic and High Purity Applications. PTFE or Silicone and AISI 316 L without asymptotic seals. All versions are fully autoclavable. Removable handle available for valves equipped with SIP connection. Documentation: Laser marking for traceability and validation processes. Material 3.1 certificates, FDA...

 Open the catalog to page 13
GENERAL  CATALOGUE-14

ASEPTIC SAMPLING VALVES Compact Aseptic Sampling Valves 1 HOSE BARB OUTLET =$>RATTIINOX ASEPTIC EQUIPMENT - DESIGN & SUPPLIER ASTM A270 Tri-Clamp - Flange design according to ASME-BPE Size * Special clamp included Int. finishing: Ra < 0,4 pm Ext. finishing: Ra < 0,8 pm Mirror Polished Max Working Conditions: 8 bar (120 psi) and 150°C (300°F) Gaskets: FDA approved SILICONE or USP CLASS VI - 121° PTFE Installation: Horizontal installation recommended

 Open the catalog to page 14
GENERAL  CATALOGUE-15

Compact Aseptic Sampling Valves1 TRI-CLAMP OUTLET =@RATTIINOX ASEPTIC EQUIPMENT -DESIGN & SUPPLIER ASTM A270 Tri-Clamp - Flange design according to ASME-BPE Size * Special clamp included Int. finishing: Ra < 0,4 pm Ext. finishing: Ra < 0,8 pm Mirror Polished Max Working Conditions: 8 bar (120 psi) and 150°C (300°F) Gaskets: FDA approved SILICONE or USP CLASS VI - 121° PTFE Installation: Horizontal installation recommended

 Open the catalog to page 15

All RATTIINOX SRL catalogs and technical brochures

  1. art030

    1  Page

  2. art.110

    2  Pages

  3. art028

    1  Page

  4. A R T. 001

    2  Pages

  5. art046

    14  Pages

  6. art057

    4  Pages

  7. art 044

    20  Pages

  8. art049

    4  Pages

  9. art061

    10  Pages

  10. art051

    26  Pages

  11. art050

    38  Pages

  12. art048

    2  Pages

  13. art045

    4  Pages

  14. art041

    1  Page

  15. art040

    4  Pages

  16. art037

    4  Pages

  17. art033

    1  Page

  18. art031

    1  Page

  19. art026

    10  Pages

  20. art023

    1  Page

  21. art022

    1  Page

  22. art002

    2  Pages

  23. CAD-rattiinox

    4  Pages

  24. Catalogue 2012

    250  Pages

  25. art053

    1  Page

  26. art115

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.