RAS

RAS

RAS

Product catalog summary
Application
The safety-limit thermostat with capillary is designed for applications up to 350°C. It is an electro-mechanical safety device that switches off when the cut-out temperature is exceeded and requires manual reset after cooling.

Features
  • Fail-safe operation with manual reset.
  • Approved to EN 60 730-1 / -2-9 standards.
  • Automatic action type: 2.B.J.K.L.
  • Time factor of sensing element as per DIN EN 14597.
  • Pollution degree: 2.
  • RoHS compliant.

Technical Data
  • Switching system: Calibrated for ambient 23°C.
  • Nominal voltage range: AC 24...400 V.
  • Nominal current range: 20 (3.3) A.
  • Service life: 500 operations at nominal load.
  • Protection against electric shock: Class I equipment.
  • Protection standard of housing: IP00 (EN60529).
  • Overvoltage category: II.
  • Switch system support: Plastic, GWT 850°C.
  • Capillary and sensing element: Copper/stainless steel.
  • Cut-out temperatures: Up to 350°C.
  • Capillary length: 300 ... 3500 mm.
  • Diameter of sensing element: 6, 6.5 mm (other sizes on inquiry).
  • Max. sensing element temperature: > tmax + 25°C.
  • Ambient temperature max: 125°C (T125).
  • Storage and transport temperature: -25...+60°C.
  • Connection terminals: Screw terminals M4x8, Tab terminals A6.3x0.8, DIN 46 244.

Examples
The document provides examples of cut-out temperatures, calibration tolerances, thermal switching differentials, and maximum sensing element temperatures for different settings (e.g., 110°C, 220°C, 350°C).
See more

Catalog excerpts

RAS-1

Safety-limit thermostatThree pole switch Application safety-limit thermostat with capillary, for applications up to 350°C. Features Electro-mechanical safety limit thermostat, fail-save. If cut-out temperature exceeded, circuit switches to OFF and stays at this position. Manual reset after sensing element has cooled by the switching differential • Approved to EN 60 730-1 / -2-9 • Feateres of automatic action: Type 2.B.J.K.L according to EN 60 730-1 / -2-9 • Time factor of sensing element according to DIN EN 14597 • Degree of pollution: 2 Technical data Switching system: Examples Cut-out temp. [°C] ^RATHGEBER REGELGERATE - UMFORMTECHNIK

 Open the catalog to page 1
RAS-2

View with tab terminals 0° View with tab terminals 90° Other products RAC Combined three pole control / limit and safety-limit thermostat 88, 716 Single pole control / limit thermostat 89, 710 Single pole safety-limit thermostat ^RATHGEBERREGELGERATE - UMFORMTECHNIK IndustriestralJe 12 • D-35756 Mittenaar-Ballersbach Fon: +49 (0)2772/9662 0 • Fax: +49 (0)2772/9662 10 E-Mail: [email protected] Internet: www.rathgeber-gmbh.de

 Open the catalog to page 2

All Rathgeber GmbH catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.