video corpo

Smoke Generation Tubes
1Pages

{{requestButtons}}

Catalog excerpts

Smoke Generation Tubes - 1

1339 Moffett Park Dr. Tube Orders 1-888-723-8823 Use & Color: Break open both ends of the tube using the tube tip breaker. Insert one end into a rubber bulb and squeeze the bulb to generate a white smoke. The tube changes from a dark reddish brown to a lighter reddish brown. The tube can be used repeatedly until it is spent. Keep the tube closed between uses with the supplied rubber caps. Reagent Type: Stannic chloride Reaction Principle: SnCl4 + H2O ^ stannic oxychlorides + 2HCl Humidity Range: 10 - 95% RH. The smoke generating life increases about 10% at 20% RH and decreases about 10% at 80% RH (incoming air humidity). Temperature Range: 0 - 40°C (32 - 104°F). As temperature decreases the smoke lasts longer and is less intense. Storage Life and Conditions: 2 years in darkness at 5 - 25°C (40 - 77°F) CAUTIONS ON USE: • Read, understand and comply with all labels, warnings and instructions accompanying these tubes before use. Failure to comply may cause serious injury or death. • For use in respirator fit testing according to OSHA 29 CFR 1910.134 (appendix A) and OSHA 1910.139. • Wear safety glasses and gloves to protect against chemical exposure and flying glass. Wear a respirator when exposed to smoke. Vapors are corrosive to skin and overexposure can result in serious injury or death. • DO NOT inhale smoke directly. If inhaled enough to cause coughing, remove victim to fresh air. If coughing persists, provide oxygen and contact a physician. • Use only in a well-ventilated area. DO NOT use in a confined space. • DO NOT use under a respirator fit testing hood or other enclosed space because fume concentrations may build up to levels that can cause serious injury or death. • Avoid contact of smoke with skin. DO NOT direct smoke stream directly at the skin during fit testing. If smoke contacts skin for prolonged time, flush with copious amounts of water for 15 minutes and contact a physician. • If smoke contacts eyes, immediately flush with water for 15 minutes and contact a physician. Eyes should be kept tightly closed during fit testing. • Use only the pump(s) at the flow rates specified in OSHA CFR 1910.134 and 29 CFR 1910.139. If the pump is operated at non-specified flow rates it could increase the smoke and fume concentrations and cause serious injury or death. • Do not use smoke tubes in areas that may contact food or food eating areas. • Do not use for fit testing on persons with pre-existing respiratory or related medical conditions or are allergic to tin compounds or hydrochloric acid. Caution: Dispose of spent or expired tubes according to local regulations. Each tube contains 0.7g of stannic chloride before use. Tube contents generate hydrochloric acid on contact with water. File N:\Tubes\Data SheetsNew\Smoke RAE 123-01

Open the catalog to page 1

All RAE Systems catalogs and technical brochures

  1. Miller ®

    4 Pages

  2. AreaRAE Pro

    8 Pages

  3. RAEShare

    1 Pages

  4. SolarRAE

    2 Pages

  5. WeatherPak

    2 Pages

  6. MBeacon

    2 Pages

  7. MicroRAE

    5 Pages

  8. MeshGuard

    2 Pages

  9. FMC-16

    2 Pages

  10. FMC 2000

    2 Pages

  11. EntryRAE

    2 Pages

  12. miniDOSE

    2 Pages

  13. DoseRAE Pro

    2 Pages

  14. QRAE 3

    2 Pages

  15. ToxiRAE Pro

    2 Pages

  16. RAEGuard LEL

    2 Pages

  17. RAEGuard PID

    2 Pages

  18. RAE Systems

    35 Pages

  19. BioHarness

    2 Pages

  20. FMC-60

    2 Pages

  21. FMC-40

    2 Pages

  22. FMC-10

    2 Pages

  23. ChemRAE

    2 Pages

  24. AutoRAE 2

    2 Pages

  25. QRAE Plus

    2 Pages

  26. QRAE II Pump

    2 Pages

  27. PlumeRAE

    2 Pages

  28. MultiRAE Pro

    2 Pages

  29. MultiRAE

    2 Pages

  30. MiniRAE Lite

    2 Pages

  31. MiniRAE 3000

    2 Pages

  32. DoseRAE

    2 Pages

Archived catalogs

  1. ppbRAE 3000

    2 Pages

  2. HazRAE

    2 Pages