Humidity Filtering II Tube
2Pages

{{requestButtons}}

Catalog excerpts

Humidity Filtering II Tube - 1

^Rae SYSTEMS by Honeywell Humidity Filtering II Tube For MiniRAE 3000 and Other Photoionization Detectors The Humidity Filtering II Tube dries the sample gas entering pumped instruments. It is particularly suited for removing humidity effects on photoionization detectors (PIDs) while making VOC measurements, and typically lasts for about a half hour of continuous readings. The Humidity Filtering II Tube utilizes a solid adsorbent to remove moisture without impacting the detection and measurement of most VOCs. KEY FEATURES Accurate • Enables continuous reading of VOCs under extremely humid conditions for about one half hour (per tube) at room temperature • Prevents drifting readings at high humidity when the sensor is dirty. Versatile • Attaches to the Flex-I-Probe™ inlet with the same adapter used for ppbRAE 3000 VOC zeroing tubes. • Especially useful for measuring chlorinated solvents and fuels under high humidity conditions as are often encountered during soil and water remediation. • Can be used with other instruments having a built-in pump such as MiniRAE Lite, ppbRAE 3000, UltraRAE 3000, MultiRAE Lite, MultiRAE and MultiRAE Pro when humidity is an issue, when using a PID or making low-level LEL sensor measurements. • Caution: Absorbs some compounds such as ammonia and slows the response of heavy compounds, especially at low concentrations or low temperatures. (Check RAE Systems' Technical Note TN-178 for adapter connections or for further details.) APPLiCATiONS Use with photoionization detectors where humidity effects need to be removed during applications such as: • Soil and water remediation • VOCs in landfill sites • Facilitates quick, on-the-spot measurements of many gases and vapors • Extends the time needed between sensor cleanings

Open the catalog to page 1
Humidity Filtering II Tube - 2

Humidity Filtering II TubeFor MiniRAE 3000 and Other Photoionization Detectors Table 1. Effect on VOC Response Note: The contents of the tubes are non-hazardous, but may absorb hazardous components from the sample gas. WORLDWIDE SALES OFFICES USA/Canada 1.877.723.2878 Europe +45.86.52.51.55 CORPORATE HEADQUARTERS RAE Systems by Honeywell 3775 North First Street San Jose, CA 95134 USA raesales@raesystems.com DS-1014-04

Open the catalog to page 2

All RAE Systems catalogs and technical brochures

  1. Miller ®

    4 Pages

  2. AreaRAE Pro

    8 Pages

  3. RAEShare

    1 Pages

  4. SolarRAE

    2 Pages

  5. WeatherPak

    2 Pages

  6. MBeacon

    2 Pages

  7. MicroRAE

    5 Pages

  8. MeshGuard

    2 Pages

  9. FMC-16

    2 Pages

  10. FMC 2000

    2 Pages

  11. EntryRAE

    2 Pages

  12. miniDOSE

    2 Pages

  13. DoseRAE Pro

    2 Pages

  14. QRAE 3

    2 Pages

  15. ToxiRAE Pro

    2 Pages

  16. RAEGuard LEL

    2 Pages

  17. RAEGuard PID

    2 Pages

  18. RAE Systems

    35 Pages

  19. BioHarness

    2 Pages

  20. FMC-60

    2 Pages

  21. FMC-40

    2 Pages

  22. FMC-10

    2 Pages

  23. ChemRAE

    2 Pages

  24. AutoRAE 2

    2 Pages

  25. QRAE Plus

    2 Pages

  26. QRAE II Pump

    2 Pages

  27. PlumeRAE

    2 Pages

  28. MultiRAE Pro

    2 Pages

  29. MultiRAE

    2 Pages

  30. MiniRAE Lite

    2 Pages

  31. MiniRAE 3000

    2 Pages

  32. DoseRAE

    2 Pages

Archived catalogs

  1. ppbRAE 3000

    2 Pages

  2. HazRAE

    2 Pages