D160- 230/460VAC Three-Phase SCR Power Controller 30A
2Pages

{{requestButtons}}

Catalog excerpts

D160- 230/460VAC Three-Phase SCR Power Controller 30A - 1

IPC Automation Inc. RAE Corporation 4615 W. Prime Parkway McHenry,IL 60050-7001 US Phone: (815) 759-3934 Fax: (815) 363-1641 E-Mail: ipcsales@msn.com Website:www.ipcautomation.com Item # 910-5252-004, D160- 230/460VAC Three-Phase SCR Power Controller 30A D160- 230/460VAC Three-Phase SCR Power Controller 30A The IPC D160 is a three-phase SCR power controller which offers variable-voltage phase-angle control for a variety of applications. Fully-isolated all-digital firing is immune to AC line distortions, RF and noise. These rugged controllers feature many standard features such as soft-start, voltage or current control input, AC or DC output, open or closed-loop operation and a variety of AC or DC feedback options. 4-20 ma current input with offset and bias adjustments. Adjustable current limit. 30 A continuous output rating. (Higher currents or other voltages on request) Also available as a trigger-only package (uses customer supplied power section). · SPECIFICATIONS · DESIGN FEATURES · OPERATING FEATURES SPECIFICATIONS Full Load Ambient Temperature Closed Loop Regulation 16 MSC 0 to 220° conduction-damping specified for closed-loop operation adjustable. ± 0.5% from ± 10 volt DC feedback signal. Drift less than 0.1% Current Limit Adjustable 50 to 200%. Overcurrent trip set at 500%. Fixed or Adjustable. 0 to ± 10 volts DC into 10K ohms input impedence. Regulated 10V 1mA output available for external 10K potentiometer. Feedback Input 0 to 10 volts DC into 10K ohms input impedence. Input scaling potentiometer with adjustable range from 10V to 100V input. Gate Outputs Output Ratings Six isolated outputs to hard-fire up to 6 SCRs. Initial pulse rises to 1 amp in less than 500 nanoseconds with a back porch of 150 ma for the remainder of the cycle. 2500V rms isolation. DESIGN FEATURES 6/4/2014 | Page 1

Open the catalog to page 1
D160- 230/460VAC Three-Phase SCR Power Controller 30A - 2

• Input 240/480V± 10% or 380/480/575 3-phase 50/60 Hz • Protection DV-DT network Voltage transient network Overcurrent trip Current limit • Isolation 2500V rms output to output and output to control potential; control circuit isolated by 2500V rms from incoming power line. • Options Current input -Option Cl 0-20 ma with offset, gain and bias Offset relay-Option-CR2-Trip Relay- Option-CR1-Nonstandard reference input available. OPERATING FEATURES • • • • • • • • • • • • Precision digital design 100% integrated circuits for better regulation and control Compact single control board, including...

Open the catalog to page 2

All RAE Corporation catalogs and technical brochures

  1. RLVS SERIES

    1 Pages

  2. RHV SERIES

    1 Pages

  3. SCR SERIES

    1 Pages

  4. G33 Series

    2 Pages

  5. G14 Series

    2 Pages

  6. G211 Series

    2 Pages

  7. G7 Series

    2 Pages

  8. G6 Series

    2 Pages

  9. G4 Series

    2 Pages

  10. M1500 Series

    2 Pages