RDW1 Series circuit breaker is mainly used in rated service current up to 6300A of distribution networks to distribute electric energy and protect lines. • AC rated current: 630-6300A; • Short-circuit breaking capacity: 80kA-120kA; • Rated working voltage below AC690V; • Both the 3 poles and 4 poles are available; • Two types:Draw-out type and fixed type: • Equipped with many types of intelligent controllers with different functions; • Standards: IEC60947-2. GB14048.2. Operation Conditions • When the ambient air temperature is -5°C to +40°C. the mean value is no greater than +35"C within 24 hours. • Altitude: not higher than 2000m for the installation site. • When the ambient air temperature is +40°C. the relative humidity of the air shall not be higher than 50%; a higher relative humidity is allowed at a lower temperature; for example, for the wettest month, the maximum relative humidity averaged shall be 90% while the lowest temperature averaged in that month +20°C. and special measures shall be taken for the condensation occasionally produced due to temperature change. • Pollution grade: Class 3. • The installation category of the breaker's main circuit is IV and the control circuit and auxiliary circuit being III. • The circuit breaker should be installed according to the manual.The vertical tilt angle should not exceed 5°. • If the air circuit breaker is installed in a small compartment of the switch board, the protection grade is up to IP40.
Open the catalog to page 1Provide Professional Low-Voltage Distribution Solutions a. Intelligent controller types: H type (communication type), M type (standard type), L type (economic type), 2M type (high immunity type) and 2H type (high immunity communication type): b.lt have overload long time-delay, short circuit short time-delay and short circuit instantaneous functions; c.single-phase earthing fault protection; d. Display function: setting current display, action current display and each phase voltage display (the voltage display should be informed when ordering); e.Alarm function: overload alarm; f.Self...
Open the catalog to page 2Intelligent Frame Type Universal Breaker ^ RDW1(DW45) Seriesv Main Technical Parameters Note:The capacity-reducing factor is 0.9 for above 2500A.The 4000A of 6000A is not reducing capacity.
Open the catalog to page 3Provide Professional Low-Voltage Distribution Solutions Energy storage handle Energy storage indication Panel Inlet and outlet device Position indicator Shake hand knob
Open the catalog to page 4RDW1(DW45) Seriesv Connection Terminals Circuit breaker have total 47 terminals.The connection diagram refer to Pic.A, Pic.B and Pic.C. #1, #2 AC AC working power supply inputflnput from DC power module U1 and U2 in AC current) #25, #26 connect with neutral pole or input from current transformer. Note: • If the F, X, M voltage of control power is different, it need connect with different power supply. #35 can be connected with power supply directlyfautomatic energy storage), also can be connected with NC button firstly, then for power supply (manual energy storage). • #6-#7 NC contact...
Open the catalog to page 5Provide Professional Low-Voltage Distribution Solutions RDW1(DW45) Seriesv • Other connection of intelligent controller #1 #2 AC working power supply input (Input from DC power module U1 and U2 in AC current) #12 overload alarm #14 Instantaneous short time-delay output #15 long time-delay output #16 earthing fault output #19 public line output #20 self-checking output #21 tripping output #25, #26 connect with neutral pole or input from current transformer Power (transformer r~J~|— Relay coil —--NO contact (8> - Indicator light Relay connection diagram 1)The controller output drives relay J...
Open the catalog to page 6RDW1(DW45) Seriesv Note: • If the F, X, M voltage of control power is different, it need connect with different power supply. • #35 can be connected with power supply directly(automatic energy storage), also can be connected with NC button firstly, then for power supply (manual energy storage). • #6-#7 NC contact output (user provide accessories) • User provide additional accessories, o When the controller working power supply is DC current, it need add DC power module.(#1 and #2 terminals cannot be connected with AC power supply).The secondary diagram refer to picture (DC110V or 220V input...
Open the catalog to page 7wide Professional Low-Voltage Distribution Solutions Note: • If the F, X, M voltage of control power is different, it need connect with different power supply. • #35 can be connected with power supply directly(automatic energy storage), also can be connected with NC button firstly, then for power supply (manual energy storage). • #6-#7 NC contact output (user provide accessories) • User provide additional accessories. When the controller working power supply is DC current, it need add DC power module.(#1 and #2 terminals cannot be connected with AC power supply).The secondary diagram refer...
Open the catalog to page 8RDW1(DW45) Seriesv Overall And Mounting Dimensions (mm) • Fixed type circuit breaker mounting and overall dimensions (RDW1-3200) • Draw-out circuit breaker mounting and overall dimensions (RDW1-2000)
Open the catalog to page 9rofessional Low-Voltage Distribution Solutions RDW1(DW45) Seriesv Overall And Mounting Dimensions (mm) • Draw-out circuit breaker mounting and overall dimensions (RDW1-3200) HofBOfMl ccrooctOn • Draw-out circuit breaker mounting and overall dimensions (RDW1-4000, 5000/3Poles)
Open the catalog to page 10RDW1(DW45) Seriesv Overall And Mounting Dimensions (mm) • Draw-out circuit breaker mounting and overall dimensions (RDW1-4000, 5000A/4P) Note: From panel center to circuit breaker center is 206.5 • Draw-out circuit breaker mounting and overall dimensions (RDW1-6300, 6300A/4ln=4000A, 5000A) Note: From panel center to circuit breaker center is 189(3P), 246.5(4P)
Open the catalog to page 11rofessional Low-Voltage Distribution Solutions RDW1(DW45) Seriesv Overall And Mounting Dimensions (mm) • Draw-out circuit breaker mounting and overall dimensions (RDW1-6300 ln=6300A) Note: From panel center to circuit breaker center is 246.5 • Draw-out circuit breaker mounting and overall dimensions (RDW1-6300/4 ln=6300A) Note: From panel center to circuit breaker center is 304