ADVANCED FLUID MANAGEMENT SOLUTIONS 5 YEARS WARRANTY Made In Italy
Open the catalog to page 1ADVANCED FLUID MANAGEMENT SOLUTIONS the human side of Quality founded in 1975
Open the catalog to page 3SERVICE COLUMNS Page 12 Frontal service columns
Open the catalog to page 4Page 18 Frontal service columns with collection tank Page 21 Bilateral service columns Page 24 Bilateral service columns with collection tank The service columns are the ideal product to use in any working environment with reduced free spaces on walls or with vertical no-loading surfaces. The wide range of available models allows to optimize and to rationalize the working spaces, satisfying both simplicity and ergonomics. Our sales department is at your disposal to provide information and solutions.
Open the catalog to page 5ADVANCED FLUID MANAGEMENT SOLUTIONS
Open the catalog to page 6More than 5000 products available for your business
Open the catalog to page 7ADVANCED FLUID MANAGEMENT SOLUTIONS
Open the catalog to page 8Technical Characteristics Universal holes to fix hose reels (see quantities and models in the table on the inside pages). The connection to the system is from the ceiling. CEILING INSTALLATION Internal preparation to mount pulser mono-valve and bi-valve for operation with FCS system. Universal holes to fix modular drip trays (not available for the stainless steel version). Solid steel structure in anti-scratch painted steel. Some models have lateral holes to attach SERIES 250, 260, 280 and 300 swivelling hose reels. The connection to the system is from the floor. FLOOR INSTALLATION Anchoring...
Open the catalog to page 10FRONTAL SERVICE COLUMNS in PAINTED steel Frontal service columns. Made of anti-scratch painted steel, they are installable on walls or like a free standing station. Available also in suction version, these columns are designed to arrange 1 fixed hose reel. COLUMN FOR SUCTION Look at the example on the left. P/N 39320 Max number of fixed hose reels that can be installed: 1 Suction pump: 1 N° 1 0,26 m3 42 kg P/N 39321 Max number of fixed hose reels that can be installed: 1 MAX NUMBER OF FIXED HOSE REELS FOR SERIES ACCESSORIES P/N 88630 Modular drip-tray equipped with hook for oil gun and removable...
Open the catalog to page 12FRONTAL SERVICE COLUMNS in PAINTED steel Frontal service columns. Made of anti-scratch painted steel, they are installable on walls or like a free standing station. These columns are designed to arrange up to 3 fixed hose reels. P/N 39323 Max number of fixed hose reels that can be installed: 3 N° 1 0,26 m3 56 kg P/N 39322 Max number of fixed hose reels that can be installed: 2 N° 1 0,26 m3 50,9 kg P/N 88630 Modular drip-tray equipped with hook for oil gun and removable drip-tray.
Open the catalog to page 13FRONTAL SERVICE COLUMNS in PAINTED steel Frontal service columns. Made of anti-scratch painted steel, they are installable on walls or like a free standing station connected to the centralized distribution system to work as independent operational stations. These columns are designed to arrange up to 9 hose reels. Floor Ceiling installation installation Max number of fixed hose reels that can be installed: 5 Max number of swivelling hose reels that can be installed: 4 Max number of swivelling hose reels that can be installed: 4 MAX NUMBER OF HOSE REELS FOR SERIES ACCESSORIES P/N 88630 Modular...
Open the catalog to page 14FRONTAL SERVICE COLUMNS in AISI 304 - 316 STAINLESS steel Front service columns. Made of AISI 304 or AISI 316 stainless steel, they are suitable to be used in the most aggressive work environments. These columns are designed to arrange up to 2 fixed hose reels and are the ideal solution for the cleaning sector. Max number of fixed hose reels that can be installed: 1 Max number of fixed hose reels that can be installed: 1 Max number of fixed hose reels that can be installed: 2 AISI 316 stainless steel AISI 304 stainless steel AISI 304 stainless steel MAX NUMBER OF FIXED HOSE REELS FOR SERIES ACCESSORIES...
Open the catalog to page 15Universal holes to install the hose reels (see quantities and models in the table on the inside pages). Internal arrangement for mounting pulser mono-valve and bi-valve for operation with FCS system. Easy hose-holder hook for dispensing guns (not available on P/N 39351 and 39352, where, instead, you can apply a modular tray and/or a suction pump). Solid steel structure in anti-scratch painted steel. Anchoring base to the floor. The connection to the system is from the ceiling. Drip tank. The emptying can be done by mounting the ball tap, that has to be ordered separately. Articles 39351 and 39352...
Open the catalog to page 16FRONTAL SERVICE COLUMNS in PAINTED steel - WITH COLLECTION TANK Front service columns with collection tank. Made of anti-scratch painted steel, they are installable on walls or like a free standing station connected to the centralized distribution system to work as independent operational stations. They have an easy drip-tray to recover any oil or fluids leaks, ensuring the cleaning of the floor. These columns are designed to arrange up to 6 fixed hose reels. MAX NUMBER OF FIXED HOSE REELS FOR SERIES ACCESSORIES P/N 38209 Ball valve G 1/2” (m) x G 1/2” (f) for emptying the drip-tank (mounting...
Open the catalog to page 18FRONTAL SERVICE COLUMNS in PAINTED steel - WITH CONTAINMENT TANK Front service columns with collection tank. Made of anti-scratch painted steel, they are installable on walls or like a free standing station connected to the centralized distribution system to work as independent operational stations. They have a sturdy containment tank to load 1 or 2 tanks up to 180 - 220 kg. These columns are designed to arrange up to 3 fixed hose reels. P/N 39351 P/N 39352 Max number of fixed hose reels that can be installed: 2 Max number of fixed hose reels that can be installed: 3 Max number of drums that...
Open the catalog to page 19Technical Characteristics The connection to the system is from the ceiling. CEILING INSTALLATION Universal holes to fix hose reels at both sides of the column (see quantities and models in the table on the inside pages). Internal preparation to mount pulser mono-valve and bi-valve for operation with FCS system. Universal holes to fix modular drip trays in both sides of the column. Solid steel structure in anti-scratch painted steel. Some models have lateral holes to attach series 250, 260, 280 and 300 swivelling hose reels. Anchoring base to the floor. The connection to the system is from the...