Series 8562/5 miniature circuit-breakers meet all technical requirements relating to safe and selective tripping. When short-circuits occur, they restrict the load on the installed circuits due to their excellent current limiting and related high breaking capacity and provide a high level of discrimination for lineside fuses. > 1 to 3 pole versions > Rated current from 0.5 ... 40 A > 6 or 10 kA breaking capacity to DIN VDE 0641, respectively EN 60898 > Isolating Function to EN 60947-2 > Permanently set thermal and magnetic trips > Power limitation class 3 Components for System Solutions E9/1
Open the catalog to page 1Selection Table other versions and accessories on request E9/2 Components for System Solutions
Open the catalog to page 2Miniature Circuit-Breaker IEC Series 8562 Selection Table Components for System Solutions E9/3
Open the catalog to page 3Miniature Circuit-Breaker 1-pole Selection Table - Order Specific Configuration Version / Version Breaking capacity AC AC UL Auxiliary contact without E9/4 Components for System Solutions 8562/..-...4-... 8562/..-...5-... -005 8562/..--005
Open the catalog to page 4Miniature Circuit-Breaker IEC Series 8562 Miniature Circuit-Breaker 1-pole Selection Table - Order Specific Configuration Version / Breaking capacity Version Breaking capacity Auxiliary contact 1 CO Fault signal 1 CO Rated operational 6 current in A 10 Components for System Solutions E9/5
Open the catalog to page 5Miniature Circuit-Breaker 1-pole + N Selection Table - Order Specific Configuration Version / Breaking capacity Version Breaking capacity Auxiliary contact E9/6 Components for System Solutions ..4-... ..5-... ...-005 ...-010 ...-020 ...-030 ...-040 ...-060 ...-100 ...-130 ...-160 ...-200 ...-250 ...-320
Open the catalog to page 6Miniature Circuit-Breaker 2-pole Selection Table - Order Specific Configuration Version / Breaking capacity Auxiliary contact Rated operational current in A Version AC AC AC / DC UL UL 135 % without 1 CO Fault signal 1 CO order spec. 0.5 1 2 3 4 6 10 13 16 20 25 32 Components for System Solutions E9/7
Open the catalog to page 7Miniature Circuit-Breaker 2-pole Selection Table - Order Specific Configuration Version / Version Breaking capacity Auxiliary contact without 8562/..-...0-... -- E9/8 Components for System Solutions 8562/..-...4-... 8562/..-...5-... -005 8562/..--005
Open the catalog to page 8Miniature Circuit-Breaker 3-pole Selection Table - Order Specific Configuration Version / Breaking capacity Auxiliary contact Rated operational current in A Version Breaking capacit without 1 CO Fault signal 1 CO 2 CO - 1 CO normal and fault signal 1 CO 0.5 1 2 3 4 6 10 13 16 20 25 32 Components for System Solutions E9/9
Open the catalog to page 9Miniature Circuit-Breaker 3-pole Selection Table - Order Specific Configuration Version / Version Breaking capacity Auxiliary contact without 8562/ 1 CO -Fault signal 1 CO - 2 CO - 1 CO normal and fault signal 1 CO -- Miniature Circuit-Breaker 3-pole + N Selection Table - Order Specific Configuration Module width Order Number Width 99 mm 8562/54-4...- Order Number Supplement Version / Breaking capacity Auxiliary contact Rated operational current in A Version Breaking capacity without 1 CO Fault signal 1 CO 2 CO - 1 CO normal and Fault signal 1 CO 6 10 13 16 20 25 32 E9/10...
Open the catalog to page 10Miniature Circuit-Breaker 3-pole + N Selection Table - Order Specific Configuration Version / Version Breaking capacity 2 CO - 1 CO normal and Fault signal 1 CO 8562/ Components for System Solutions E9/11
Open the catalog to page 11Explosion Protection Marking lECEx Europe (ATEX) Certificates lECEx Europe (ATEX) Other certificates IECEx PTB 06.0062U PTB 02 ATEX 1049 U Belarus (Gospromnadzor) Technical Data Device version Version No. of poles Electrical data Version Rated operational voltage AC MCBs 1 pole, 1 pole + N, 2 pole, 3 pole, 3 pole + N AC / DC MCBs 1 pole, 2 pole AC MCBs Standard version AC DC 1 pole + N 230 V - - AC / DC MCBs Standard version AC DC 1 pole + N - - - - Minimal Voltage Ubmin Maximal Voltage Ub max Rated insulation voltage 500 V 500 V Rated operational current Tripping...
Open the catalog to page 12Miniature Circuit-Breaker IEC Series 8562 Technical Data Electrical data Tripping characteristic curves Components for System Solutions
Open the catalog to page 13Technical Data Electrical data Tripping characteristic curves Selectivity class 3 (IEC/EN 60898) Breaking capacity 6 kA resp. 10 kA Rated switching capacities AC MCBs Poles Series with 6 kA Series with 10 kA DC to IEC/EN 609472 (Time constante 15 ms) Circuit breaker, current limiting with thermal and magnetic release E9/14 Components for System Solutions 2016-04-04-EK00-ili-en
Open the catalog to page 14Technical Data Characteristics Characteristic to IEC/EN 60898 Rated current range Loads Normal temperature Thermal overload trip Thermal overload trip 135% UL Magnetic trip B 6 ... 32 A > Elektric heatings > Lighting > Socket outlet circuits > Control circuits e.t.c. 30 °C 1.13 ... 1.45 In > Operating equipment > Light fitting groups > Motors > Transformers D 0.5 ... 32 A > Operating equipment > Motors with heavy starting characteristic e.t.c. 30 °C 1.13 ... 1.45 In Components for System Solutions E9/15
Open the catalog to page 15Technical Data Electrical data Response value of short-circuit trip Back-up protection The response value of the short-circuit trip is approximately 40 % higher for DC than for AC at 50 / 60 Hz Fuses must be fitted upstream to protect miniature circuit-breakers against high short-circuit currents in high power networks. These protect the miniature circuit-breakers against short-circuit currents of up to 50 kA. If a short-circuit occurs, both protective devices cut out simultaneously, so that the miniature circuit-breaker is not destroyed and remains fully functional. Following MCBs...
Open the catalog to page 16Technical Data Mechanical data Degree of protection Degree of protection acc. to IEC/EN 60529 Connecting terminals IP20 Material Enclosure Epoxy resin Mounting / Installation Terminals Main contacts 1.5 ... 10 mm2 clamp terminals Auxilliary contacts 1.5 mm2 clamp terminals Universal current +/-, 1 pole Universal current +/-, 2 pole Fault indication contact 1 CO Auxiliary contact 1 NO Fault indication contact 1 NO 12219E00 Auxiliary contact 1 CO Fault indication contact 1 CO Undervoltage trip Components for System Solutions E9/17
Open the catalog to page 17All R. STAHL AG catalogs and technical brochures
-
IS1+ The Remote I/O
16 Pages
-
NETWORK TECHNOLOGY
20 Pages
-
HMIs IN OIL & GAS APPLICATIONS
20 Pages
-
Actuators Series 8602/3
20 Pages
-
PRODUCT CATALOGUE 2019
909 Pages
-
electrical catalog 9016
236 Pages
-
IS1+ Remote I/O - future inside
16 Pages
-
CATALOGUE 2018
1094 Pages
-
Floodlight LED Series 6125
7 Pages
-
LED floodlight 6125
2 Pages
-
WLAN ACCESS POINT 8265
5 Pages
-
ModibEx by R. STAHL
4 Pages
-
Small Fuse Bases Series 8560
4 Pages
-
Contactor Relay Series 8510
5 Pages
-
Ex-Poster
1 Pages
-
BROCHURE: LIGHTING
24 Pages
-
Signalling_Catalogue_S2_2014
148 Pages
-
Condensed Catalogue 2015
622 Pages
-
LinearLuminaire_EK00_III
7 Pages
-
AK00_III
12 Pages
-
EN/IEC 61439
4 Pages
-
Seminare D-A-CH 2014
25 Pages
-
IsolatingRepeater_AK00_III_
6 Pages
-
AnalogInputModule_AK00_III
5 Pages
-
SERIES 200
8 Pages
-
HMI Oil and Gas
20 Pages
-
HMI Overview
36 Pages
-
SolConeX
12 Pages
-
Together we invent the solution
12 Pages
-
HVAC and pressurization
12 Pages
-
GUBox
4 Pages
-
Pedant light fittings
16 Pages
-
Inspection Light 6149/2
4 Pages
-
Portable Lamp 6148
4 Pages
-
EXLUX 6001
4 Pages
-
Focus customer
24 Pages
-
IsolatingRepeater_AK00_II
6 Pages
-
AK00_III
5 Pages
-
BinaryOutput_Auto
5 Pages
-
9160601310_de_en
24 Pages
-
STAHL HMI Solutions
32 Pages
-
Distributing and Controlling
19 Pages
-
Lighting
16 Pages
-
Competence at a glance
24 Pages
-
Isolators
6 Pages
-
Safety Barriers
27 Pages
-
Ex Magazine 2012
70 Pages
-
IS1+Remote I/O
16 Pages
-
Stahl - Catalog
1306 Pages
Archived catalogs
-
ISpac isolators
16 Pages
-
IS1 remote I/O
12 Pages
-
Fieldbus Solutions
16 Pages
-
Cable glands
18 Pages
-
Lighting
16 Pages
-
Distributing and Controlling
20 Pages
-
Company brochure
24 Pages
-
Marine Solutions
24 Pages
-
Poster Explosion Protection
1 Pages