IsolatingRepeater_AK00_III_
6Pages

{{requestButtons}}

Catalog excerpts

IsolatingRepeater_AK00_III_ - 1

Fibre Optics Fieldbus Isolating Repeater Series 9186 > Easy installation and mainetance due to: – Inherently safe optical interface – Intrinsically safe bus connection via RS-485 IS (PNO) > High availability due to: – Build-up of ring structures, redundant Point-to-Point, line structures – Integrated analysis of optical input signal – Error message if critical levels of input signal reached > Transmission of Profibus DP, Modbus, HART on RS-485, R. STAHL Servicebus > 9186/.5 – Installation in Zone 2 possible > 9186/12 – Installation in Zone 1 and Zone 2 possible – Fieldbus interface for intrinsically safe Profibus DP (PNO) The Fibre Optic Isolating Repeater is used to build-up fibre optic network structures in hazardous areas. It enables to transmit Profibus DP or Modbus signals over distances of up to 2 km or 1,2 miles. The optical interfaces are designed to be inherently safe (Ex op is). The protection scheme Ex op is allows to apply usual standardized industry connectors. The Zone 1 / Div. 2 version of the Fibre Optic Isolating Repeater offers an intrinsically safe RS-485 interface acc. to the standard RS-485 IS (PNO). Critical levels of the received optical signal are detected by the integrated diagnostic function. The fault is indicated by LEDs on the front side of the device and in addition by a line fault contact. The contact is used to trigger a remote fault indication in the control room. The diagnostic function enables preventive maintenance and improves the availability of the plant. IECEx / ATEX

Open the catalog to page 1
IsolatingRepeater_AK00_III_ - 2

Fibre Optics Fieldbus Isolating Repeater Series 9186 Selection Table Version Network structure Order number Fibre optics fieldbus isolating repeater Series 9186 Ring, point-to-point redundant, line Zone 2 and in the safe area Ring, point-to-point redundant, line Explosion Protection Global (IECEx) Version Installation in Gas and dust Europe (ATEX) Version Installation in Gas and dust Certifications and certificates Version Installation in Certificates Ship approval Safety data Version Installation in Max. voltage Uo Max. current Io Max. power Po For connection RS 485 IS Max. permissible...

Open the catalog to page 2
IsolatingRepeater_AK00_III_ - 3

Fibre Optics Fieldbus Isolating Repeater Series 9186 Technical Data Electrical data Version Installation in Auxiliary power Nominal voltage UN Voltage range Residual ripple Nominal current (at UN) Power input Operation indication Polarity reversal protection Galvanic separation Test voltage acc. to standard between RS-485 and power supply Ex i RS485 to power supply Error-contact to power supply PA to power supply Ex i RS 485 to error-contact Ex i RS 485 to PA Error contact to PA Optical interface Protocols Network topologies Redundancy Connection Wavelength Transmission distance Recommended...

Open the catalog to page 3
IsolatingRepeater_AK00_III_ - 4

Fibre Optics Fieldbus Isolating Repeater Series 9186 Technical Data Fault control Power supply failure Transmission level is good Transmission level reduced (-1,5 dBm) Fibre breakage or transmission level is too low (-3 dBm) Version Installation in Switching capacity of fault-contact Ambient conditions Version Installation in Ambient temperature Storage temperature Relative humidity (no condensation) Connectors Version Installation in Power supply Fault-contact Screen connection to PA Serial connection Shield Fibre optic cable Mechanical data Version Installation in Weight Mounting type...

Open the catalog to page 4
IsolatingRepeater_AK00_III_ - 5

Fibre Optics Fieldbus Isolating Repeater Series 9186 Technical Data Electrical connection Connection diagram Accessories and Spare Parts Designation 9-pin for connection of the fieldbus or ServiceBus to the CPU & power module Series 9440/15 and fieldbusisolating repeater 9185. Integrated terminator can be switched on or off. For non-intrinsically safe RS-485. 9-pin for connection of the fieldbus or ServiceBus to the CPU & power module Series 9440/22 and fieldbusisolating repeater 9185. Integrated terminator can be switched on or off. For RS-485 IS to PNOstandard. 9-pin, for connection of...

Open the catalog to page 5
IsolatingRepeater_AK00_III_ - 6

Fibre Optics Fieldbus Isolating Repeater Dimensional Drawings (All Dimensions in mm / inches) - Subject to Alterations Safe area Hazardous area Safe area Hazardous area Point-to-Point structure Line structure We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding.

Open the catalog to page 6

All R. STAHL AG catalogs and technical brochures

  1. CATALOGUE 2018

    1094 Pages

  2. Ex-Poster

    1 Pages

  3. AK00_III

    12 Pages

  4. EN/IEC 61439

    4 Pages

  5. SERIES 200

    8 Pages

  6. HMI Overview

    36 Pages

  7. SolConeX

    12 Pages

  8. GUBox

    4 Pages

  9. EXLUX 6001

    4 Pages

  10. Focus customer

    24 Pages

  11. AK00_III

    5 Pages

  12. Lighting

    16 Pages

  13. Isolators

    6 Pages

  14. IS1+Remote I/O

    16 Pages

  15. Stahl - Catalog

    1306 Pages

Archived catalogs

  1. IS1 remote I/O

    12 Pages

  2. Cable glands

    18 Pages

  3. Lighting

    16 Pages