Catalog excerpts
Isolating Repeater Loop Powered Field Circuit Ex i Series 9167/..-11-00 > For HART output signals 0/4 ... 20 mA > Intrinsically safe output [Ex ia] IIC > Galvanic isolation between inputs and outputs > Without power supply > Very low internal resistance > HART communication signal transmitting, bidirectionally > For use up to SIL 3 (IEC 61508) A3 The Isolating Repeaters loop powered are used for intrinsically safe operation of control values, i/p-converters, analog and digital indicators, fire & gas detectors etc. The modules transmit the HART communication signal bidirectionally. A separate power supply is not required. ATEX / GOST Class I Class II Class III Restrictions see table explosion protection
Open the catalog to page 1Isolating Repeater Loop Powered Field Circuit Ex i Series 9167/..-11-00 Selection Table Version Order number Isolating Repeater, Loop Powered Series 9167, Field Circuit Ex i The order numbers listed in the table are for transducers equipped with screw terminals. For transducers equipped with spring clamp terminals, replace the ending "s" for screw terminals with "k" for spring clamp terminals.
Open the catalog to page 2Isolating Repeater Loop Powered Field Circuit Ex i Series 9167/..-11-00 Explosion Protection Global (IECEx) Gas and dust Europe (ATEX) Gas and dust USA (NEC) Gas and dust Russia (Gost-R) Gas Certificates and approvals Certificates Other approvals Safety data Version Max. voltage Uo / Voc Max. current Io / Isc Max. power Po Max. connectable capacitance Co / Ca IIC IIB Max. connectable inductance Lo / La IIC IIB internal capacitance Ci internal inductance Li Rated insulation voltage Um Further parameters Installation Further information Functional safety (IEC 61508) Test report Max. SIL Safe...
Open the catalog to page 3Isolating Repeater Loop Powered Field Circuit Ex i Series 9167/..-11-00 Technical Data Electrical data Version Auxiliary power Supply Max. power losses per channel 20 mA 40 mA Galvanic isolation Test voltages Acc. to standard Ex i output to input Ex i outputs to each other Acc. to standard Inputs to each other Input from nonhazardous location Input signal IE Input_Function range Internal resistance Ri (at 20 mA) (at 40 mA) additional constant voltage drop ãU Own consumption Input voltage UE Max. effective voltage UE eff Polarity reversal protection Ex i output Output signal Function range...
Open the catalog to page 4Isolating Repeater Loop Powered Field Circuit Ex i Series 9167/..-11-00 Technical Data Electrical connection Connection diagram Hazardous area Safe area Field device ISpac Isolator Control system Hazardous area Safe area Field device ISpac Isolator Technical Data Mechanical data Connection A3 Spring clamp terminals Connection single-wire - rigid - flexible - flexible, end covering sleeves (without / with plastic sleeving) Connection two wires - rigid - flexible - flexible, end covering sleeves Weight Installation type Installation position Enclosure Terminals Enclosure material Fire...
Open the catalog to page 5Isolating Repeater Loop Powered Field Circuit Ex i Series 9167/..-11-00 Dimensional Drawings (All Dimensions in mm / inch) - Subject to Alterations 17,6 mm / 0.69 “ Screw terminals Spring cage terminals We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding.
Open the catalog to page 6All R. STAHL AG catalogs and technical brochures
-
IS1+ The Remote I/O
16 Pages
-
NETWORK TECHNOLOGY
20 Pages
-
HMIs IN OIL & GAS APPLICATIONS
20 Pages
-
Actuators Series 8602/3
20 Pages
-
PRODUCT CATALOGUE 2019
909 Pages
-
electrical catalog 9016
236 Pages
-
IS1+ Remote I/O - future inside
16 Pages
-
CATALOGUE 2018
1094 Pages
-
Floodlight LED Series 6125
7 Pages
-
LED floodlight 6125
2 Pages
-
WLAN ACCESS POINT 8265
5 Pages
-
ModibEx by R. STAHL
4 Pages
-
Small Fuse Bases Series 8560
4 Pages
-
Contactor Relay Series 8510
5 Pages
-
Ex-Poster
1 Pages
-
BROCHURE: LIGHTING
24 Pages
-
Signalling_Catalogue_S2_2014
148 Pages
-
Condensed Catalogue 2015
622 Pages
-
LinearLuminaire_EK00_III
7 Pages
-
AK00_III
12 Pages
-
EN/IEC 61439
4 Pages
-
Seminare D-A-CH 2014
25 Pages
-
IsolatingRepeater_AK00_III_
6 Pages
-
AnalogInputModule_AK00_III
5 Pages
-
SERIES 200
8 Pages
-
HMI Oil and Gas
20 Pages
-
HMI Overview
36 Pages
-
SolConeX
12 Pages
-
Together we invent the solution
12 Pages
-
HVAC and pressurization
12 Pages
-
GUBox
4 Pages
-
Pedant light fittings
16 Pages
-
Inspection Light 6149/2
4 Pages
-
Portable Lamp 6148
4 Pages
-
EXLUX 6001
4 Pages
-
Focus customer
24 Pages
-
AK00_III
5 Pages
-
BinaryOutput_Auto
5 Pages
-
9160601310_de_en
24 Pages
-
STAHL HMI Solutions
32 Pages
-
Distributing and Controlling
19 Pages
-
Lighting
16 Pages
-
Competence at a glance
24 Pages
-
Isolators
6 Pages
-
Safety Barriers
27 Pages
-
Ex Magazine 2012
70 Pages
-
IS1+Remote I/O
16 Pages
-
Stahl - Catalog
1306 Pages
Archived catalogs
-
ISpac isolators
16 Pages
-
IS1 remote I/O
12 Pages
-
Fieldbus Solutions
16 Pages
-
Cable glands
18 Pages
-
Lighting
16 Pages
-
Distributing and Controlling
20 Pages
-
Company brochure
24 Pages
-
Marine Solutions
24 Pages
-
Poster Explosion Protection
1 Pages