Catalog excerpts

IS1+ The Remote I/O - 1

IS1+ THE REMOTE I/O Expect the best for all hazardous areas

Open the catalog to page 1
IS1+ The Remote I/O - 2

For 30 years, explosion-protected remote I/O systems from R. STAHL have been used for a wide range of process automation applications in Zone 1 and 2 as well as in Division 1 and 2. It is here that they have proven to be the most cost-effective solution with regards to procurement and installation (CAPEX) as well as during operation (OPEX). Thanks to their large range of functions and unique flexibility, remote I/O solutions from R. STAHL are suitable for virtually all tasks relating to process technology. • Savings in field wiring and associated project engineering. • No need to take up...

Open the catalog to page 2
IS1+ The Remote I/O - 3

SIMPLY THE BEST REMOTE I/O With the intrinsically safe IS1+ Remote I/O, R. STAHL has set standards on which the market has been based up to the present day. • xtension, modification, maintenance – in ongoing E operation in Zone 1 and 2 or Division 1 and 2. • Hot-swappable for all modules and fieldbus interface connections in Zone 1 and 2 or Division 1 and 2. • Extensive protocol support: PROFIBUS DP, Modbus TCP + RTU, PROFINET, EtherNet/IP. • Extended temperature range -40 °C to +75 °C. • Use of cost-effective Ex e GRP or stainless steel field enclosures – no Ex d or Ex p solutions...

Open the catalog to page 3
IS1+ The Remote I/O - 4

SAFE AREA Modbus Modbus Modbus TCP + RTU TCP RS485 (IS1+ ServiceBus) RS485 (PROFIBUS DP, Modbus RTU) Ethernet (PROFINET, EtherNet/IP, Modbus TCP) RS485-I.S. (Ex i ServiceBus), RS485-I.S. (PROFIBUS DP, Modbus RTU) FO “op is“ (PROFIBUS DP, Modbus RTU, Ethernet

Open the catalog to page 4
IS1+ The Remote I/O - 5

Fieldbus isolating repeater Ex i PROFIBUS DP, Modbus RTU. SAFE AREA Fibre optic isolating repeater “op is“ PROFIBUS DP, Modbus RTU. Switch 4 FX/2 TX “op is“ fibre optic. Zone 2 CPU and Power Module PROFIBUS DP, PROFINET, Modbus TCP, EtherNet/IP. Zone 2 I/O modules for Ex i field devices. Zone 2 I/O modules for non-Ex i field devices. Zone 1 CPU and Power Module PROFIBUS DP, Modbus RTU. Ex i analogue/digital field signals Non-Ex i analogue/digital field signals Zone 1 CPU and Power Module PROFIBUS DP, PROFINET, Modbus TCP, EtherNet/IP. Zone 1 I/O modules for Ex i field devices. Zone 1 I/O...

Open the catalog to page 5
IS1+ The Remote I/O - 6

YOUR BENEFITS AT A GLANCE IS1+ SUPPORTS PROFIBUS DP, PROFINET, MODBUS TCP/RTU AND ETHERNET/IP. Flexible and easy to use in virtually any automation system. IS1+ BASED ON GLOBAL STANDARDS. Can be combined with other products and technologies regardless of the manufacturer and process control system. IS1+ FACILITATES INSTALLATION AND MAINTENANCE. By effectively combining types of protection, there is no need for the “d“ and “p“ enclosure – all components in Zone 1 and 2 or Division 1 and 2 are hot-swappable. IS1+ IS EASY TO PLAN AND QUICK TO INSTALL. IS1+ IS UNIQUELY ROBUST AND DURABLE....

Open the catalog to page 6
IS1+ The Remote I/O - 7

IS1+ IS INNOVATION WITH 30 YEARS OF EXPERIENCE. IS1+ is our third generation of remote I/O. Our experienced system specialists mean that we can find solutions for virtually all requirements. IS1+ IS DESIGNED AND MANUFACTURED FOR EXTREME ENVIRONMENTS. Can be used both horizontally and vertically for temperatures from -40 °C to +75 °C. Also perfect for use on offshore platforms and LNG tankers. IS1+ IS CONTINUOUSLY BEING EXTENDED AND OPTIMISED. As a result of our continuous further development, the system is becoming increasingly diverse – but is always downward compatible. IS1+ INCREASES THE...

Open the catalog to page 7
IS1+ The Remote I/O - 8

REMOTE I/O IS1+ IN DETAIL Modbus Modbus Modbus TCP + RTU TCP 24 V DC or 120/230 V AC * Power supply for Ex i supply of 8 Zone 1 or 16 Zone 2 modules. * for Zone 1 PROFIBUS DP and Modbus RTU. Increased availability with CPU, Power Module or system redundancy and ring structures. Free fieldbus selection via rotary switch ** and multiprotocol CPU.** ** For new Zone 2 CPU. Plant asset management and engineering via ServiceBus or process bus. Intrinsically safe fieldbus via copper cable or inherently safe “op is“ with fibre optic

Open the catalog to page 8
IS1+ The Remote I/O - 9

4-, 8- and 16-channel modules for Ex i and non-Ex i signals, digital outputs with SIL2. Extensive integrated diagnostics for signal errors or maintenance requirements with LED indicators and alarms. Ex i and non-Ex i signals can be mixed on the BusRail and are hot-swappable in Zone 1 and 2 or Division 1 and 2. Robust BusRail installation with internal Ex i system bus for power supply and data transmission. Detachable terminals for field signals in screw-type and spring terminals, with lock.

Open the catalog to page 9
IS1+ The Remote I/O - 10

Signal/error status LED per channel. Extensive diagnostics, maintenance requirements display with blue LED. Downward compatible with previous models. Multifunctional input/output, adjustable parameters. Communications modules for Zone 1 and Zone 2 or Division 1 and 2 Protocols Power supply Type series Modbus TCP or EtherNet/IP or PROFINET PROFIBUS DP, PROFINET, EtherNet/IP and Modbus TCP Zone 2 and Division 2 I/O modules, Ex i signals Function Channels Application Type series Analogue Universal Module HART Analogue inputs/outputs: 0/4 … 20 mA with HART Temperature Input Module Resistance...

Open the catalog to page 10
IS1+ The Remote I/O - 11

Separate shutdown input Shuts down all digital outputs – suitable for SIL2. Special functions e.g., integrated solenoid valves in Zone 1 and Division 1. Modules with Ex i and non-Ex i signals can be mixed in the system. Zone 1 and Division 1 I/O modules, Ex i signals Function Channels Application Type series Analogue Universal Module HART 8 Analogue inputs/outputs: 0/4 … 20 mA with HART Temperature Input Module Resistance thermometers (2-, 3-, 4-wire), THCs and potentiometers, joysticks Digital Input Output Module Digital inputs/outputs: Contacts, proximity switches and low-power solenoid...

Open the catalog to page 11
IS1+ The Remote I/O - 12

THE STANDARD FOR ZONE 1 AND 2 OR DIVISION 2 STANDARD ENCLOSURES FOR IS1+ – DELIVERY TIMES APPROX. 3 WEEKS. IS1+ Remote I/O offers great flexibility for a wide range of intended purposes. We have designed a series of STANDARD field enclosures based on many years of experience with customer-specific system solutions. These field enclosures are available from stock with short delivery times and already meet most requirements in the standard version. For even greater flexibility, in the STANDARD+ version, we provide the option of performing adaptations and modifications in a very short time...

Open the catalog to page 12

All R. STAHL AG catalogs and technical brochures

  1. CATALOGUE 2018

    1094 Pages

  2. Ex-Poster

    1 Pages

  3. AK00_III

    12 Pages

  4. EN/IEC 61439

    4 Pages

  5. SERIES 200

    8 Pages

  6. HMI Overview

    36 Pages

  7. SolConeX

    12 Pages

  8. GUBox

    4 Pages

  9. EXLUX 6001

    4 Pages

  10. Focus customer

    24 Pages

  11. AK00_III

    5 Pages

  12. Lighting

    16 Pages

  13. Isolators

    6 Pages

  14. IS1+Remote I/O

    16 Pages

  15. Stahl - Catalog

    1306 Pages

Archived catalogs

  1. IS1 remote I/O

    12 Pages

  2. Cable glands

    18 Pages

  3. Lighting

    16 Pages