Catalog excerpts
remote I/O future inside
Open the catalog to page 1Remote I/O solutions for today and tomorrow Systems with PROFIBUS DP and Ethernet Asset Management Level Control Level Field Level Zone 2 Field Level Zone 1 2 Fieldbus Isolating Repeater Fibre Optics Ex op is Ex-Interface Level
Open the catalog to page 2Think Tnrlay ahnuT Tnmnrrnw_ For many years now, IS1 has been the system that is most often installed in explosive atmospheres all over the world. It is continuously improved and expanded by new functions, such as PROFIBUS redundancy, DTM support, integration of optical rings or modules with integrated solenoid valves. In combination with more than 30 years of expertise and know-how in system solutions by R. STAHL, almost every task can be solved. With IS1 Ethernet, the first step towards the future was taken in 2009 - the first Remote I/O with communication via Industrial Ethernet in Zone...
Open the catalog to page 3Ifiss is mnm - multifunctional mnílnlns IÜ1+ +Analog Universal Module HART, 8 channels For the intrinsically safe operation of 2-wire transmitters, including supply, and of positioners with standard signals ranging from 0/4 to 20 mA. Digital communication with the connected field devices can be effected bidirectionally via the HART protocol. Every channel can be parameterized as input or output. Versions: 9468/32-08-11 AUMH, 8 channels for Zone 1 with Ex ¡ inputs/outputs and channel status LEDs 9468/33-08-10 AUMH, 8 channels for Zone 2 with Ex ¡ inputs/outputs + Digital Input Output Module,...
Open the catalog to page 4Yniir plus: ThR nnwl/0 mnriulRS IS1+_ Plants can now be operated even more effectively with the new or improved functions of the multifunctional modules. Ex- tended diagnostics and status messages make processes more transparent and give warning of failures in due time. The innovative low-power design does not only saves energy but also significantly extends lifetime - even at higher ambient temperatures. New modules, optimized for Zone 2, allow for further savings and the guaranteed downward compatibility protects your investments. Multifunctional - parameters Increased temperature range...
Open the catalog to page 5I Railing fnr fixplnsivfi aTmnsphfims With the explosion-protected Remote I/O system IS1, R. STAHL set standards that still serve as market standards to this day: unique flexibility, efficiency and profitability. IS1+fulfils all these requirements even better, no matter how com- plex your facility is. With the completely intrinsically safe system structure with intrinsically safe fieldbus, IS1+ can be easily extended and modified in hazardous areas (hot work, hot swap). Our long-standing experience with almost all auto- mation systems and the respective bus protocols, and of course the...
Open the catalog to page 6The real innovation is its simplicity - another advantage of IS1+. The system can be mounted and modified without any requirement for special engineering software, complicated regulations or tools. Almost anything is possible - horizontal or vertical assembly, vacant positions and preconfigured vacancies or a last-minute change of modules on site. + BusRail -the modular & stable system basis The internal wiring of the system for energy, data and address lines. Sensi- tive backplane solutions or numerous nectors are not required. Just snap it onto a DIN rail and the installation is For...
Open the catalog to page 7Optimal procfiss availahility FxtRnsix/R iliapsiic features COMMUNICATION PROTOCOL To optimize processes in process engineering plants and to reduce downtime, informative diagnoses and integration of the devices in Asset Management Sys- tems become more and more important. For conventional analogue field devices, the well-established HART protocol is used in most cases. Remote I/O systems also have to offer the option of being integrated into the diagnostic structure and making HART information transparently available. The times in which each ma- nufacturer offered their own, proprietary...
Open the catalog to page 8Optimi plant availahility IS1+ offers various configuration possibilities to maximize the plant availability for critical processes. +System redundancy To achieve the best availability, all system components and cables are installed in a redundant way. The standard PROFIBUS slave re- dundancy is used with PROFIBUS DP, extended with IS1+ to support other flying master systems too. For Ethernet, redundant networks are supported as well - with a reaction time of less than 200 ms. +Media redundancy The good-value solution that works together with any PROFIBUS DP master. Two cables are connected...
Open the catalog to page 9Q System snliitinns with ISI-f FnginRRring mariR hy fl. ÜTAHI Offshore and marine applications where space is restricted + Ready for connection for Zone 1 with ATEX and lECEx approvals + Compact cabinet with double door for space-saving opening + Installation of 3 Remote I/O systems for 150 analogue or 300 digital signals + Cable shields are attached directly to the input side - optimum EMC properties + Integration of mA displays in the front doors + Additional indicator lamps, push-buttons and emergency stop buttons integrated on the front of the cabinet and connected directly to the...
Open the catalog to page 10Tim whnlfi is mnm than the sum nf ¡ís pans_ From the idea to the implementation of a project, R. STAHL is a competent partner. With our 30 years of experience world- wide with different system solutions in explosion protection we will surely find a solution. From planning to commissio- ning. From service to maintenance and modernization. Mobile offshore drilling unit + NEC500-conform solution for Class I Division 1 + Remote I/O system IS1 with PROFIBUS DP communication + Non-intrinsically safe circuits with conduit connection + Installation in a high-quality stainless steel enclosure,...
Open the catalog to page 11Q GInhal nistnmfirs - glnhal prnjficts A fRw RxamplRS frnm all nvRr ThR wnrlfl In Germany, the country of origin of remote I/O, there is also one of the world's first installations with Ethernet in Zone 1 and it even features redundant communication. The IS1 is one of the very few Remote I/O systems that can be fully utilized in a Division 1 in accordance with NEC500 requirements. This is for a customer from chemical 'I industries who uses the system as their standard solution. Remote I/O goes offshore Robust and compact - Remote I/O field stations certified for use in Zone 1 and Zone 2 on...
Open the catalog to page 12All R. STAHL AG catalogs and technical brochures
-
IS1+ The Remote I/O
16 Pages
-
NETWORK TECHNOLOGY
20 Pages
-
HMIs IN OIL & GAS APPLICATIONS
20 Pages
-
Actuators Series 8602/3
20 Pages
-
PRODUCT CATALOGUE 2019
909 Pages
-
electrical catalog 9016
236 Pages
-
IS1+ Remote I/O - future inside
16 Pages
-
CATALOGUE 2018
1094 Pages
-
Floodlight LED Series 6125
7 Pages
-
LED floodlight 6125
2 Pages
-
WLAN ACCESS POINT 8265
5 Pages
-
ModibEx by R. STAHL
4 Pages
-
Small Fuse Bases Series 8560
4 Pages
-
Contactor Relay Series 8510
5 Pages
-
Ex-Poster
1 Pages
-
BROCHURE: LIGHTING
24 Pages
-
Signalling_Catalogue_S2_2014
148 Pages
-
Condensed Catalogue 2015
622 Pages
-
LinearLuminaire_EK00_III
7 Pages
-
AK00_III
12 Pages
-
EN/IEC 61439
4 Pages
-
Seminare D-A-CH 2014
25 Pages
-
IsolatingRepeater_AK00_III_
6 Pages
-
AnalogInputModule_AK00_III
5 Pages
-
SERIES 200
8 Pages
-
HMI Oil and Gas
20 Pages
-
HMI Overview
36 Pages
-
SolConeX
12 Pages
-
Together we invent the solution
12 Pages
-
HVAC and pressurization
12 Pages
-
GUBox
4 Pages
-
Pedant light fittings
16 Pages
-
Inspection Light 6149/2
4 Pages
-
Portable Lamp 6148
4 Pages
-
EXLUX 6001
4 Pages
-
Focus customer
24 Pages
-
IsolatingRepeater_AK00_II
6 Pages
-
AK00_III
5 Pages
-
BinaryOutput_Auto
5 Pages
-
9160601310_de_en
24 Pages
-
STAHL HMI Solutions
32 Pages
-
Distributing and Controlling
19 Pages
-
Lighting
16 Pages
-
Competence at a glance
24 Pages
-
Isolators
6 Pages
-
Safety Barriers
27 Pages
-
Ex Magazine 2012
70 Pages
-
Stahl - Catalog
1306 Pages
Archived catalogs
-
ISpac isolators
16 Pages
-
IS1 remote I/O
12 Pages
-
Fieldbus Solutions
16 Pages
-
Cable glands
18 Pages
-
Lighting
16 Pages
-
Distributing and Controlling
20 Pages
-
Company brochure
24 Pages
-
Marine Solutions
24 Pages
-
Poster Explosion Protection
1 Pages