> Floodlight Zones 1,2 and 21,22 with highly efficient LEDs > 3 different light distribution types for adjusting to the illumination task > Enclosure made of sheet steel single powder coated or stainless steel V4 A (SS316L) double powder coated for marine applications > Broad operating temperature range from -30 ... +50 °C > Low-maintenance due to long service life of up to 100,000 operating hours Explosion Protection Global (IECEx) Gas and dust IECEx EPS 15.0087 Ex db eb op is IIB T4 Gb Ex tb IIIC T80°C, T95°C Db Europe (ATEX) Gas and dust EPS 15 ATEX 1 114 E II 2G Ex db eb op is IIB T4 Gb E II 2D Ex tb IIIC T80°C, T95°C Db Type Power Ambient temperature Certifications and certificates Certificates IECEx, ATEX, India (PESO)
Open the catalog to page 1Selection Table Light Terminals Cable Material Order number Art. no. distribution glands Sheet steel Stainless steel V4A Sheet steel Stainless steel V4A Sheet steel Stainless steel V4A Sheet steel Stainless steel V4A Sheet steel Stainless steel V4A Sheet steel Stainless steel V4A Sheet steel Stainless steel V4A Sheet steel Stainless steel V4A Sheet steel Stainless steel V4A Sheet steel Stainless steel V4A Sheet steel Stainless steel V4A Sheet steel Stainless steel V4A
Open the catalog to page 2Selection Table Light Terminals Cable Material Order number Art. no. distribution glands Sheet steel Stainless steel V4A Sheet steel Stainless steel V4A Sheet steel Stainless steel V4A Sheet steel Stainless steel V4A Sheet steel Stainless steel V4A Sheet steel Stainless steel V4A Sheet steel Stainless steel V4A Sheet steel Stainless steel V4A Sheet steel Stainless steel V4A Sheet steel Stainless steel V4A Sheet steel Stainless steel V4A Sheet steel Stainless steel V4A
Open the catalog to page 3Technical Data Luminous characteristics Colour rendering [CRI] > 70 wide beam Luminous flux [lm] 11,763 medium beam Luminous flux [lm] 11,155 narrow beam Luminous flux [lm] 12,081 Values apply to Ta = +25 °C. Luminous flux decrease at Ta = +50 °C • > 90 % of the nominal value. (120 W Version) • > 60 % of the nominal value. (210 W Version) Loop in/loop out max. 12 A
Open the catalog to page 4E2 Light Distribution Curves
Open the catalog to page 5Floodlight LED Series 6125 Light Distribution Curves
Open the catalog to page 6E2 Dimensional Drawings (All Dimensions in mm [inches]) - Subject to Alterations 180,50 [7,11] 133,50 [5,26] Floodlight Series 6125 with cooling element (210 W version) Floodlight Series 6125 without cooling element (120 W version) Mounting bracket We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding.
Open the catalog to page 716 Pages
20 Pages
20 Pages
20 Pages
909 Pages
236 Pages
1094 Pages
16 Pages
2 Pages
5 Pages
4 Pages
4 Pages
5 Pages
1 Page
24 Pages
622 Pages
148 Pages
7 Pages
12 Pages
4 Pages
25 Pages
24 Pages
6 Pages
5 Pages
8 Pages
20 Pages
36 Pages
12 Pages
12 Pages
12 Pages
4 Pages
16 Pages
4 Pages
4 Pages
4 Pages
6 Pages
5 Pages
24 Pages
16 Pages
32 Pages
19 Pages
16 Pages
24 Pages
27 Pages
70 Pages
1306 Pages
5 Pages
6 Pages
24 Pages
24 Pages
20 Pages
16 Pages
18 Pages
16 Pages
12 Pages
16 Pages