BIOGAS 3000

BIOGAS 3000

BIOGAS 3000

Product catalog summary
Overview: The BIOGAS 3000 is a fixed biogas and landfill gas analyzer designed for continuous monitoring of gas production processes. It supports up to four sample ports to measure CH4, CO2, O2, H2S, and H2 levels, ensuring optimal process control and regulatory compliance.
Specifications:
  • Monitors up to 4 sample points for comprehensive gas control.
  • Continuous monitoring with a full-color display.
  • Calibration to ISO/IEC 17025 standards.
  • IP65 rated enclosure for durability.
  • Certified for use in CSA, ATEX, and IECeX Zone 2 areas.
  • Communication options include Modbus RTU, with optional Profibus and Profinet.
Technical Specifications:
  • Gas cells measure CH4, CO2, O2, with optional H2S, H2, and CO.
  • Response times vary by gas, with CH4 and CO2 ≤10 seconds.
  • Operating temperature range from 0°C to +50°C without heater, -20°C to +50°C with heater.
  • Power supply: 110-230 VAC, 50/60Hz, with a maximum consumption of 155W.
Features:
  • Simultaneous multi-gas sampling.
  • Verification of H2S removal.
  • Enhanced data collection and safety notifications.
  • Corrosion-resistant and suitable for explosive atmospheres.
  • Remote communication capabilities for flexible system integration.
Applications:
  • Anaerobic Digestion
  • Biogas Monitoring
  • Landfill Gas Monitoring
Certifications:
  • ISO17025 calibrated under UKAS accreditation.
  • ATEX / IECEx and CSA certified for safety and electromagnetic compatibility.
See more

Catalog excerpts

BIOGAS 3000-1

BIOGAS 3000 BIOMETHANE FIXED BIOGAS AND LANDFILL GAS ANALYSER | ANAEROBIC DIGESTION THE BIOGAS 3000 BUILDS ON FIELD-PROVEN GAS ANALYSIS TECHNOLOGY TO OFFER COST-EFFECTIVE ONLINE MONITORING. The BIOGAS 3000 is our next generation fixed analyzer that offers optimal continuous monitoring of the gas production process, using up to four sample ports to monitor CH4, CO2, O2, H2S and H2 levels. The BIOGAS 3000 design builds on previous analyzer strengths and incorporates easy installation with on-site maintenance of all parts, resulting in zero operational downtime for servicing. The hot swap device saves time and allows you to keep working. The Biogas 3000 works as long as you do. *Does not apply to auto calibration section. 2355 Bishop Circle West Dexter, MI 48130,USA Easy Installation and operation. Get up and running quickly. ATEX and CSA certified and meeting Method 21 requirements for regulatory compliance. © Product designs and specifications are subject to change without notice. User is responsible for determining suitability of product.

 Open the catalog to page 1
BIOGAS 3000-2

Up to 4 sample points to monitor the complete gas control process Monitor before and after desulphurization Continuous monitoring Option Full Color display Calibration to ISO/IEC 17025 Built-in Liquid level monitoring with dedicated alarm and fault notifications IP65 Rated enclosure Certified for use in CSA, ATEX and IECeX Zone 2 areas Modbus RTU communication Optional Profibus and Profinet communication *Plus accuracy of calibration gas used QED Environmental Systems Inc. 2355 Bishop Circle West Dexter, MI 48130,USA

 Open the catalog to page 2
BIOGAS 3000-3

BENEFITS APPLICATIONS WQHU • Sample multiple gases simultaneously • Verify removal of H2S • Increased data collection • Easy-to-Read • Optimum accuracy • Precise notification and increased saftey • Highly corrosion resistant • Use in potentially explosive gas atmospheres - zone 2 • Remote communication • More flexible system intergration TECHNICAL SPECIFICATIONS CONTINUED • Anaerobic Digestion • Biogas Monitoring • Landfill Gas Monitoring LANDTEC BIOGAS 3000 PUMP 1 Continuous option will include a minimum 3 minute daily air purge QED Environmental Systems Inc. 2355 Bishop Circle West Dexter,...

 Open the catalog to page 3
BIOGAS 3000-4

© Product designs and specifications are subject to change without notice. User is responsible for determining suitability of product. 2355 Bishop Circle West Dexter, MI 48130,USA

 Open the catalog to page 4

All QED Environmental catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.