1. Catalogs
  2. QAWRUMS Ltd.
  3. QAWRUMS Acoustic Emission Sensors Selection Guide

QAWRUMS Acoustic Emission Sensors Selection Guide

QAWRUMS Acoustic Emission Sensors Selection Guide
1 / 14 PagesView full catalog

QAWRUMS Acoustic Emission Sensors Selection Guide

Product catalog summary
Overview: This document is a selection guide and technical comparison for QAWRUMS Acoustic Emission Sensors, detailing models and specifications for browsing, model screening, and technical discussions.
Sensor Categories: Sensors are categorized into general-purpose, integral preamplifier, wideband, high-temperature, miniature, differential, intrinsically safe, and customized designs.
Selection Parameters: Key parameters include resonant frequency, frequency range, sensitivity, preamplifier type, size, temperature rating, protection grade, connector type, and application suitability.
System Compatibility: Sensors are designed for QAWRUMS systems and compatible with standard acoustic emission acquisition instruments, given power, impedance, and connector requirements are met.
Choosing an AE Sensor: Recommendations are provided based on application needs, with specific models suggested for metal crack detection, partial discharge, and geological monitoring.
Model Specifications: Detailed specifications include resonant frequency, frequency range, sensitivity, size, weight, working temperature, and protection level, along with materials, connection types, and typical applications.
Commonly Used Models: Models G150, GI150, G40, and GI40 are highlighted for applications in metallic-structure, leakage, corrosion, and partial-discharge.
Passive vs. Integral Preamplifier: Differences between passive sensors and those with integral preamplifiers are explained, including typical use cases and installation considerations.
High Temperature and Intrinsically Safe Sensors: Specifications for high-temperature and intrinsically safe sensors emphasize their use in extreme environments and safety-critical applications.
Miniature and Wideband Sensors: Miniature sensors are recommended for narrow spaces, while wideband sensors are suitable for spectrum research and composite materials.
Conclusion: Final specifications, certification, cable assembly, and environmental suitability should be confirmed at the time of quotation.
Specifications and Models: Models like WI800 and WM500/1 are made from SUS 304 ceramic and stainless steel, designed for specific cable types and applications in spectrum research and composite materials.
Waterproof and Environmental Considerations: SMA connector models can have upgraded protection grades. Standard waterproof sensors are suitable for fresh water, while customized solutions are needed for harsher environments.
Customization Options: Sensors can be customized for sensitivity, frequency response, cable length, connector type, and temperature resistance.
Compatibility and Selection Checklist: A checklist guides the selection process, confirming compatibility regarding connectors, power supply, signal polarity, and impedance.
Connection Diagrams: Connection setups for passive sensors with external preamplifiers and integral-preamplifier sensors are outlined.
Frequently Asked Questions: The FAQ section addresses common queries about choosing AE sensors, frequency usage, broadband sensor applications, and customization possibilities.
Contact Information: Contact details are provided for assistance in selecting an AE sensor.
See more

Catalog excerpts

QAWRUMS Acoustic Emission Sensors Selection Guide-1

QAWRUMS ACOUSTIC EMISSION TECHNOLOGY Acoustic Emission Sensor Model List Selection guide and technical comparison Fast model comparison Frequency, sensitivity, temperature, preamplifier, dimensions, protection, connection and application. Customer-ready reference Use this PDF for browsing, model screening and technical discussions. General purpose | Integral preamp | Wideband High temperature | Miniature | Differential Intrinsically safe | Customized designs Prepared from the online model list - July 2026

 Open the catalog to page 1
QAWRUMS Acoustic Emission Sensors Selection Guide-2

Selection Guide and Technical Comparison QAWRUMS | Acoustic Emission Sensor Model List Complete sensor portfolio General-purpose, integral preamplifier, broadband, high-temperature, miniature, differential, intrinsically safe and customized acoustic emission sensors. Selection parameters Compare resonant frequency, frequency range, sensitivity, preamplifier type, size, temperature rating, protection grade, connector and application. System compatibility Designed for QAWRUMS systems and compatible with many standard acoustic emission acquisition instruments when power, impedance and connector...

 Open the catalog to page 2
QAWRUMS Acoustic Emission Sensors Selection Guide-3

QAWRUMS | Acoustic Emission Sensor Model List Selection Guide and Technical Comparison Commonly Used Acoustic Emission Sensors Four frequently selected models cover many metallic-structure, leakage, corrosion and partial-discharge applications. Final selection should still consider attenuation, noise, installation conditions and system compatibility. Frequency range: 60-400 kHz Sensitivity peak: >75 dB Configuration: Passive Typical use: Metal crack or fault diagnosis Frequency range: 60-400 kHz Sensitivity peak: >75 dB Configuration: 40 dB / 28 V integral preamp Typical use: Metal cracks, partial...

 Open the catalog to page 3
QAWRUMS Acoustic Emission Sensors Selection Guide-4

Selection Guide and Technical Comparison QAWRUMS | Acoustic Emission Sensor Model List Sensitivity peak dB Integral preamp Working temp. °C Protection G150 Leakage and slope monitoring G10/1 SUS 304 Ceramic Single-core LEMO Side M36 RG178 Note: Data is reproduced and typographically normalized from the online model list. Confirm final specifications, certification, cable assembly and environmental suitability at quotation.

 Open the catalog to page 4
QAWRUMS Acoustic Emission Sensors Selection Guide-5

Selection Guide and Technical Comparison QAWRUMS | Acoustic Emission Sensor Model List Partial discharge, leakage, corrosion Note: Data is reproduced and typographically normalized from the online model list. Confirm final specifications, certification, cable assembly and environmental suitability at quotation.

 Open the catalog to page 5
QAWRUMS Acoustic Emission Sensors Selection Guide-6

Selection Guide and Technical Comparison QAWRUMS | Acoustic Emission Sensor Model List Spectrum research WI800/1 SUS 304 Ceramic SMA Side Saddle type RG178 / RG316 Note: Data is reproduced and typographically normalized from the online model list. Confirm final specifications, certification, cable assembly and environmental suitability at quotation.

 Open the catalog to page 6
QAWRUMS Acoustic Emission Sensors Selection Guide-7

Selection Guide and Technical Comparison QAWRUMS | Acoustic Emission Sensor Model List Sensitivity peak dB Integral preamp Note: Data is reproduced and typographically normalized from the online model list. Confirm final specifications, certification, cable assembly and environmental suitability at quotation.

 Open the catalog to page 7
QAWRUMS Acoustic Emission Sensors Selection Guide-8

Selection Guide and Technical Comparison QAWRUMS | Acoustic Emission Sensor Model List Sensitivity peak dB Integral preamp Note: Data is reproduced and typographically normalized from the online model list. Confirm final specifications, certification, cable assembly and environmental suitability at quotation.

 Open the catalog to page 8
QAWRUMS Acoustic Emission Sensors Selection Guide-9

Selection Guide and Technical Comparison QAWRUMS | Acoustic Emission Sensor Model List Sensitivity peak dB Integral preamp Working temp. °C Protection GD150 Materials, connection and recommended useModel Case material Sensing face Connector Location Hold-down Cable model Typical applications GD150 SUS 304 Ceramic Dual-core BNC on integral cable Side M20A - Crack detection in high-noise environments GD40 SUS 304 Ceramic Dual-core BNC on integral cable Side Saddle type - Partial discharge, leakage, corrosion Note: Data is reproduced and typographically normalized from the online model list. Confirm...

 Open the catalog to page 9
QAWRUMS Acoustic Emission Sensors Selection Guide-10

Selection Guide and Technical Comparison QAWRUMS | Acoustic Emission Sensor Model List Sensitivity peak dB Integral preamp Note: Data is reproduced and typographically normalized from the online model list. Confirm final specifications, certification, cable assembly and environmental suitability at quotation.

 Open the catalog to page 10
QAWRUMS Acoustic Emission Sensors Selection Guide-11

Selection Guide and Technical Comparison QAWRUMS | Acoustic Emission Sensor Model List Sensitivity peak dB Integral preamp Note: Data is reproduced and typographically normalized from the online model list. Confirm final specifications, certification, cable assembly and environmental suitability at quotation.

 Open the catalog to page 11
QAWRUMS Acoustic Emission Sensors Selection Guide-12

Selection Guide and Technical Comparison QAWRUMS | Acoustic Emission Sensor Model List SMA connector models: Protection grade may be upgraded according to cable and sealing design. A waterproof cable assembly is required for waterproof installations. Standard waterproof designs: Standard waterproof sensors are generally intended for fresh water at room temperature. Seawater, salt-lake water, corrosive liquids or long-term underwater use at elevated temperature require a customized sealing and material solution. Customization: Sensitivity, frequency response, cable length, connector type, mounting...

 Open the catalog to page 12
QAWRUMS Acoustic Emission Sensors Selection Guide-13

QAWRUMS | Acoustic Emission Sensor Model List Selection Guide and Technical Comparison AE Sensor Connection Diagrams 1. Passive sensor + external preamplifier + professional AE acquisition system + SWAE software 2. Passive sensor + externally powered preamplifier + general analog input / oscilloscope 3. Integral-preamplifier sensor + professional AE acquisition system + SWAE software

 Open the catalog to page 13
QAWRUMS Acoustic Emission Sensors Selection Guide-14

QAWRUMS | Acoustic Emission Sensor Model List Selection Guide and Technical Comparison Frequently Asked Questions 1. How do I choose an acoustic emission sensor? Choose according to material, expected AE source, frequency range, sensitivity, operating temperature, installation space, background noise and acquisition-system compatibility. 2. What is the most commonly used AE sensor frequency? For many metallic structures, 150 kHz resonant sensors are commonly used because they provide high sensitivity and good signal-to-noise performance for crack detection and structural monitoring. 3. When should...

 Open the catalog to page 14

All QAWRUMS Ltd. catalogs and technical brochures

  1. SVLD1

    26  Pages

  2. WI800

    1  Page

  3. PAS3

    2  Pages

  4. WI800-1

    1  Page

  5. WI500-1

    1  Page

  6. WI500

    1  Page

  7. W800-1

    1  Page

  8. W800

    1  Page

  9. W500-1

    1  Page

  10. W500

    1  Page

  11. LS5VDCB

    1  Page

  12. LS5VDCA

    1  Page

  13. GSI150

    1  Page

  14. GM150-1

    1  Page

  15. GM150

    1  Page

  16. WM500-1

    1  Page

  17. GIS35

    1  Page

  18. GI150-4

    1  Page

  19. GI150-3

    1  Page

  20. GI150-2

    1  Page

  21. GI150-1

    1  Page

  22. GI150

    1  Page

  23. GI80

    1  Page

  24. GI40-2

    1  Page

  25. GI40

    1  Page

  26. GI35-2

    1  Page

  27. GI35-1

    1  Page

  28. GI35

    1  Page

  29. GI10-1

    1  Page

  30. GI10

    1  Page

  31. GH150-2

    1  Page

  32. GH150-1

    1  Page

  33. GH150

    1  Page

  34. G150-2

    1  Page

  35. G150-1

    1  Page

  36. G150

    1  Page

  37. G80-1

    1  Page

  38. G80

    1  Page

  39. G40

    1  Page

  40. G10-1

    1  Page

  41. G10

    1  Page

  42. GD150

    1  Page

  43. GD14

    1  Page

  44. Waveguide

    2  Pages

  45. Vacuum Holder

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.