QL Series-2

QL Series Positive Displacement Pumps Max. Pressure Rating= 290 psi (Viscous Liquids) Viscosity Correction Factor (v) Standard Clearances Standard Port Size = 1.0” Displacement = 0.013 Gal/Rev (0.050 L/Rev) Q-Pumps QL Series Model: QL10 Operating Specifications:  0-1000 RPM Range  290 PSI (20 bar) Max. Pressure  Temperature Range -40 oF (-40oC) to 250 oF (121oC) Correction Factor 15 Subject to change without notice Where: p = pressure (psi or bar) v = viscosity correction factor (from graph) (English units) Total Power (HP) = (.0007 p + .0051 v) n c n = speed (RPM) (Metric units) Total Power...

 Open the catalog to page 2
QL Series-3

Max. Pressure Rating= 175 psi (Viscous Liquids) Standard Clearances Standard Port Size = 1.5” Displacement = 0.032 Gal/Rev (0.121 L/Rev) QL Series Positive Displacement Pumps Viscosity Correction Factor (v) Operating Specifications:  0-800 RPM Range  175 PSI (12.07 bar) Max. Pressure  Temperature Range -40 oF (-40oC) to 250 oF (121oC) Correction Factor Subject to change without notice Where: p = pressure (psi or bar) v = viscosity correction factor (from graph) Viscosity (cP) n = speed (RPM) (English units) Total Power (HP) = (.0007x p + .0051x v) xnx c c = displacement (G/rev. or L/rev from...

 Open the catalog to page 3
QL Series-4

Operating Specifications:  0-800 RPM Range  115 PSI (7.93 bar) Max. Pressure  Temperature Range -40 oF (-40oC) to 250 oF (121oC) Viscosity Correction Factor (v) Correction Factor Standard Clearances Standard Port Size = 2.0” Displacement = 0.056 Gal/Rev (0.212 L/Rev) Q-Pumps QL Series Model: QL20 QL Series Positive Displacement Pumps Subject to change without notice (English units) Total Power (HP) = (.0007x p + .0051x v) xnx c (Metric units) Total Power (Kw) = (2x p + v)xnx c 1000 www.qpumps.com Where: p = pressure (psi or bar) v = viscosity correction factor (from graph) n = speed (RPM)...

 Open the catalog to page 4
QL Series-5

QL Series Positive Displacement Pumps 0 Q-Pumps QL Series Model: QL22 Standard Clearances Standard Port Size = 2.0” Displacement = 0.106 Gal/Rev (0.401 L/Rev) Operating Specifications:  0-700 RPM Range  175 PSI (12.07 bar) Max. Pressure  Temperature Range -40 oF (-40oC) to 250 oF (121oC) Viscosity Correction Factor (v) Correction Factor Subject to change without notice (English units) Total Power (HP) = (.0007x p + .0051x v) xnx c (Metric units) Total Power (Kw) = (2x p + v)x nx c 1000 v = viscosity correction factor (from graph) n = speed (RPM) c = displacement (G/rev. or L/rev from table...

 Open the catalog to page 5
QL Series-6

QL Series Positive Displacement Pumps GPM Q-Pumps QL Series Model: QL25 Standard Clearances Standard Port Size = 2.5” Displacement = 0.164 Gal/Rev (0.621 L/Rev) Operating Specifications:  0-700 RPM Range  115 PSI (7.93 bar) Max. Pressure  Temperature Range -40 oF (-40oC) to 250 oF (121oC) Viscosity Correction Factor (v) Correction Factor Subject to change without notice (English units) Total Power (HP) = (.0007x p + .0051x v) xnx c (Metric units) Total Power (Kw) = (2x p + v)x nx c 1000 v = viscosity correction factor (from graph) n = speed (RPM) c = displacement (G/rev. or L/rev from table...

 Open the catalog to page 6
QL Series-7

QL Series Positive Displacement Pumps 0 Q-Pumps QL Series Model: QL33 Standard Clearances Standard Port Size = 3.0” Displacement = 0.269 Gal/Rev (1.018 L/Rev) Correction Factor Operating Specifications: Viscosity Correction Factor (v) • 0-600 RPM Range • 175 PSI (12.07 bar) Max. Pressure • Temperature Range -40 oF (-40oC) to 250 oF (121oC) 5 Subject to change without notice (English units) Total Power (HP) = (.0007x p + .0051x v)x nx c (Metric units) Total Power (Kw) = (2x p + v)x nx c 1000 v = viscosity correction factor (from graph) n = speed (RPM) c = displacement (G/rev. or L/rev from table...

 Open the catalog to page 7
QL Series-8

Q-Pumps QL Series Model: QL34 Standard Clearances Standard Port Size = 4.0” Displacement = 0.380 Gal/Rev (1.438 L/Rev) Operating Specifications:  0-600 RPM Range  115 PSI (7.93 bar) Max. Pressure  Temperature Range -40 oF (-40oC) to 250 oF (121oC) Viscosity Correction Factor (v) Correction Factor QL Series Positive Displacement Pumps Subject to change without notice (English units) Total Power (HP) = (.0007x p + .0051x v) xnx c (Metric units) Total Power (Kw) = (2x p + v)x nx c 1000 Where: p = pressure (psi or bar) v = viscosity correction factor (from graph) n = speed (RPM) c = displacement...

 Open the catalog to page 8
QL Series-9

WATER CAPACITY AND ABSORBED POWER GRAPH |f LU 1000 < 800 J 600 o 400 ^ 200 0 ABSORBED kW FIGURES ARE FOR 1 CP VISCOSITY Q-Pumps QL Series Model: QL44 Standard Clearances Standard Port Size = 4.0" Displacement = .60 Gal/Rev 2.27 L/Rev Operating Specifications • 0-500 RPM range Subject to change without notice

 Open the catalog to page 9
QL Series-10

Q-Pumps QL Series Model: QL46 Standard Clearances Standard Port Size = 6.0" Displacement = 0.88 Gal/Rev 3.34 L/Rev (English units) Total Power (HP) = (.0007* p + ,0051*v)*n*c (Metric units) Total Power (Kw) = (2*p + v)*n*c 1000 Where: p = pressure (psi or bar) v = viscosity correction factor (from graph) n = speed (RPM) c = displacement (G/rev. or L/rev from table below) Operating Specifications • 0-500 RPM range Max. Pressure • Temperature range -40°F (-40°C) to 250°F(121°C) Subject to change without notice

 Open the catalog to page 10

All Q-Pumps catalogs and technical brochures

  1. All Series

    18  Pages

  2. QC/QC+ SERIES

    4  Pages

  3. QL SERIES

    4  Pages

  4. QP SERIES

    8  Pages

  5. QTS Series

    8  Pages

  6. SIS+ Series

    4  Pages

  7. QC Series

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.