PURION® THE BEST SOLUTION SOLUTIONS FOR TREATMENT OF WATER
Open the catalog to page 1PURION® THE BEST SOLUTION UV: DISINFECTION WITHOUT CHEMICALS UVC based disinfection operating principle 3 configuration options for monitoring of the PURION UV plants 4-8 disinfection of water and liquids 9 - 62 equipment spare parts 63 - 72 company with tradition and innovation 73 - 76
Open the catalog to page 2visible light OPERATING PRINCIPLE Wavelength at around 264 nm effectively inactivate microorganism. Microorganisms such as bacteria, moulds, yeasts and protozoa can be destroyed or removed by physical, biological and chemical methods. UVC works using a photolytic effect whereby the radiation destroys or inactivates the microorganism so that it can no longer multiply. The phenomenon whereby microorganisms can be disfigured or destroyed is independent of host state (fluid or solid) and indeed pH or temperature. Therefore disinfection of fluides, air and surfaces without using chemicals or...
Open the catalog to page 3CONFIGURATION OPTIONES FOR MONITORING OF THE PURION UV-PLANTS PURION guarantees disinfection for an operating time up to max. 10.000 h or max. 8.000 h for PURION UV-lamps with Amalgam technology for high ambient temperaturees up to 90 C°. After 10.000 h or 8.000 h of operation the UVC-intensity falls below 60% of the initial value. All technical performance data of the PURION UV plants have been derived from this “end of life” value. Therefore the PURION UV-lamp has to be replaced after 10.000 h / 8.000 h. The UVC-light that is decisive for disinfection has a wavelength of approx. 260 nm...
Open the catalog to page 4PURION Monitoring of the UV-lamps operational time Operating Time Counter -OTC The Operating Time Counter (OTC) option monitors the life time of the UV lamp via summation of the operating time. The current status is displayed via LED's. The OTC option works as a time counter and is integrated in the control box. The monitoring system is designed as a traffic light. Two thresholds for the operating time have been saved: - As long as the operating time is below 95% of the guaranteed life time the green LED is illuminated. - If the operating time exceeds 95% of the guaranteed life time...
Open the catalog to page 5Operating Power Detection OPD The Operating Power Detection (OPD) option monitors the life time of the UV lamp via detecting the UV intensity. The current status is displayed via LED's. product line Operating Power Detection - OPD automatic recording of the exact 230 V AC or 12 V DC or UVC intensity that is currently ge pply 24 V DC signal input automatic (pre-)alarm when lamp replacement is necessary signal output safe reset procedure maintenance free operation optional: potential free contact for any LED load potential free contacts special function calibration after replacement of...
Open the catalog to page 6This sensor is suitable for monitoring of the intensity of PURION UVC low-pressure lamps, PURION UVC high-output lamps und PURION UVC amalgam lamps. silicon carbide chip warrants extreme radiation power The sensor is equipped with a silicon carbide photodiode (SiC). The photodiode has a very good sensitivity within the range of 250 and 260 nm. Therfore the diode is suitable to monitor UV light that is used for disinfection and with a peak emission rate at 254 nm. This is in line with the DNS absorbtion curve. The monitoring unit is designed as a traffic light. During monitoring the...
Open the catalog to page 7linear sensitivity to light (A/W) This sensor is suitable for monitoring of the intensity of PURION UVC low-pressure lamps, PURION UVC high-output lamps und PURION UVC amalgam lamps. angle spread approx. 30° 0°C up to 60°C stainless steel 1.4571 connection flanges supplied voltage TO-18 metallic housing - 0.054 mm² active chip surface power output silicon carbide chip warrants extreme radiation power optimal ability for measuring powerful UVC radiation wideband UVA-UVB-UVC Photodiode product line in a stainless steel housing with integrated booster and power output The sensor type is...
Open the catalog to page 8PVC-U Single-plants PURION Single UV-plants for disinfection of water and liquids are available in stainless steel 1.4571. Therefore Requirements of the drinking water regulation con be met. PURION Single UV-plants made from stainless steel are available for several flow rates. Moreover it is possible to choose from various options for monitoring the disinfection performance of the PURION UV-lamps, e.g. sensor systems to detect the current UVC-intensity. PURION Single UV-plants for disinfection of water and liquids are available in PVC-U. Therefore the UV-plants can be operated for...
Open the catalog to page 10Single-plants PURION guarantees disinfection up to a temperature of 40 C° of the water or fluid as a standard configuration. Temperatures above 40 C° lead to a decreasing UVC output und therefore a less disinfection performance. The UV-plants of the PURION H series are using a special Amalgam technology and have been developed for warm and hot environments up to 90 C°. The PURION UV-lamps of the H series are perfectly suitable to remove Legionella bacteria in warm water circuits. PURION guarantees disinfection for a UVC transmission of >90%T1cm as a standard configuration. For disinfection...
Open the catalog to page 11The UV-plant PURION 400 is made from electropolished stainless steel 1.4571. The PURION 400 is applied to disinfect drinking water up to a flow rate of 300 l/h and a transmission (or turbidity) of the water of at least 90% per cm. Due to the compact design and the options for power supply with direct current the UV-Plant PURION 400 is perfectly suitable for mobile applications. equipment PURION 400 & 500 assembly system Single 1 stainless steel article number: 290 11000 0000 assembly system Single 1 galvanized article number: 290 10900 0000 PURION UV-lamp 10 W article number: 200 01300 0000...
Open the catalog to page 12The UV-plant PURION 500 is made from electropolished stainless steel 1.4571. The PURION 500 is applied to disinfect drinking water up to a flow rate of 400 l/h and a transmission (or turbidity) of the water of at least 90% per cm. For the UV-plant PURION 500 the complete range of PURION options to monitor the disinfection performance is available. The PURION 500 can be operated with direct current.
Open the catalog to page 13All PURION GmbH catalogs and technical brochures
-
Datasheet PURION UVC BOX
1 Pages
-
CATALOG OF PRODUCTS
118 Pages
-
PURION Solutions pour la surface
32 Pages