PURION 2500 DUAL 90 W configuration option DUALOPD Professional & DUAL OPD Ultra

PURION 2500 DUAL 90 W configuration option DUALOPD Professional & DUAL OPD Ultra

Product catalog summary
Overview
The document describes the PURION DUAL OPD Ultra and Professional monitoring options for UV lamp systems, focusing on their operational capabilities, safety features, and technical specifications.
Specifications
  • Control System: Both versions integrate the control system into a single electronic cabinet with Operating Power Detection (OPD 2) for monitoring UVC intensity.
  • Backup Mechanism: The systems ensure high safety by automatically switching on a second UV plant or interrupting water flow if UVC intensity is insufficient.
  • Control Cabinet Dimensions: 250 x 350 x 160 mm.
  • Signal Lights: Two for operating status and two for disinfection power (2x OPD 2).
  • Electrical Connection: 110-240 V 50/60 Hz and 12 V DC.
  • Over Current Protection: 10 A for AC and 6 A for DC.
  • Protection Type: IP 54.
Advantages
  • Integrated electric control system in one cabinet.
  • High safety through UVC intensity monitoring and backup mechanisms.
  • Cost-effective equipment acquisition.
Additional Equipment for Ultra Version
  • Supplied and electrically prefabricated magnet valve for enhanced safety.
Flow Rates
  • PURION 1000 DUAL: 2 m3/h
  • PURION 2500 DUAL 36 W: 5 m3/h
  • PURION 2500 DUAL 90 W: 8 m3/h
  • PURION 2001 DUAL: 10 m3/h
  • PURION 2501 DUAL: 20 m3/h
  • PURION 1000 DUAL H: 3 m3/h
  • PURION 2500 DUAL H: 8 m3/h
  • PURION 2501 DUAL H: 20 m3/h
See more

Catalog excerpts

PURION 2500 DUAL 90 W configuration option DUALOPD Professional & DUAL OPD Ultra-1

monitoring option DUAL OPD Ultra monitoring option DUAL-plants With the version PURION DUAL OPD is possible to operate one or both UV lamps. The control system is realized in one electronic control cabinet with Operating Power Detection (OPD 2) for both UV lamps to monitor the UVC intensity. The second UV plant in flow direction can be additionally switched on (priority circuit). If only the first UV plant (in flow direction) is operated the second UV plant will be immediately and automatically switched on if there is an error or too less UVC intensity within the first UV plant. With this backup mechanisms in case of operation only one UV lamp, a very high degree of safety is ensured. With the version PURION DUAL OPD Ultra both UV lamps are switched and operated simultaneously. For both plants a monitoring of the UVC intensity is integrated (OPD 2). Both plants are equipped with a potential free contact to switch the magnet valve. In case of an error or too less UVC intensity the water flow will be immediately and automatically interrupted by the magnet valve. A renewed release of the water flow requires the correction of the error. The version DUAL Professional OPD enables a well engineered protection to ensure the guaranteed disinfection power.

 Open the catalog to page 1

All PURION GmbH catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.