PURION 1000 DUAL configuration option DUAL OPD Professional & DUAL OPD Ultra

PURION 1000 DUAL configuration option DUAL OPD Professional & DUAL OPD Ultra

Product catalog summary
Overview: The document describes the PURION DUAL OPD Ultra and Professional monitoring options for UV lamp operation, focusing on safety and efficiency in disinfection processes.
Specifications:
  • Both versions allow operation of one or both UV lamps with integrated UVC intensity monitoring (OPD 2).
  • Control system housed in a single electronic cabinet with dimensions 250 x 350 x 160 mm.
  • Electrical connection options include 110-240 V 50/60 Hz and 12 V DC, with overcurrent protection of 10 A (AC) and 6 A (DC).
  • Type of protection: IP 54.
Procedures:
  • In the DUAL OPD Ultra version, both UV lamps operate simultaneously, and a magnet valve interrupts water flow if errors or low UVC intensity are detected.
  • The DUAL Professional OPD version provides engineered protection to maintain disinfection power.
Advantages:
  • High safety level through UVC intensity monitoring and backup mechanisms.
  • Cost-effective equipment acquisition.
  • Integrated electric control system in one cabinet.
Flow Rates:
  • PURION 1000 DUAL: 2 m3/h
  • PURION 2500 DUAL 36 W: 5 m3/h
  • PURION 2500 DUAL 90 W: 8 m3/h
  • PURION 2001 DUAL: 10 m3/h
  • PURION 2501 DUAL: 20 m3/h
  • PURION 1000 DUAL H: 3 m3/h
  • PURION 2500 DUAL H: 8 m3/h
  • PURION 2501 DUAL H: 20 m3/h
See more

Catalog excerpts

PURION 1000 DUAL configuration option DUAL OPD Professional & DUAL OPD Ultra-1

monitoring option DUAL OPD Ultra monitoring option DUAL-plants With the version PURION DUAL OPD is possible to operate one or both UV lamps. The control system is realized in one electronic control cabinet with Operating Power Detection (OPD 2) for both UV lamps to monitor the UVC intensity. The second UV plant in flow direction can be additionally switched on (priority circuit). If only the first UV plant (in flow direction) is operated the second UV plant will be immediately and automatically switched on if there is an error or too less UVC intensity within the first UV plant. With this backup mechanisms in case of operation only one UV lamp, a very high degree of safety is ensured. With the version PURION DUAL OPD Ultra both UV lamps are switched and operated simultaneously. For both plants a monitoring of the UVC intensity is integrated (OPD 2). Both plants are equipped with a potential free contact to switch the magnet valve. In case of an error or too less UVC intensity the water flow will be immediately and automatically interrupted by the magnet valve. A renewed release of the water flow requires the correction of the error. The version DUAL Professional OPD enables a well engineered protection to ensure the guaranteed disinfection power.

 Open the catalog to page 1

All PURION GmbH catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.