1. Catalogs
  2. Pulsarlube
  3. Operation manual E
video corpo

Operation manual E

Operation manual E

Operation manual E

Product catalog summary
Installation and Disposal Guidelines
1. Remove contaminants around the lubrication point and install appropriate adaptors after removing the grease nipple.
2. Align the window on the housing cap with the body for proper positioning.
3. After the dispensing period of the Pulsarlube E is complete, remove the lubricator.
4. Use a flat-head screwdriver to detach the PCB and remove the batteries.
5. Push the Mode Selector into the desired period slot and unscrew the battery cover to remove it.
6. Disassemble the product for disposal by turning the housing cap counterclockwise.
7. Dispose of plastic components according to local recycling regulations.

Mounting Installations
1. Use an angle adapter for installations at 45° or 90° angles.
2. For remote installations, use 8mm O.D. tubing with a maximum distance of 1m.
3. Ensure a clear passage with a manual grease gun and use compatible grease.
4. Note that dispensing may be delayed by up to 1-3 weeks depending on conditions.

Product Details and Certifications
1. The Pulsarlube E is designed for single-point lubrication and should be directly mounted when possible.
2. For remote installations, use pre-filled tubing with compatible grease.
3. The product is intrinsically safe and should be cleaned with a damp cloth to avoid electrostatic hazards.
4. The temperature code is T4: -25°C to +55°C.

Dispensing Volume and Warranty
1. The shelf life is 1 year from production, with a warranty covering defects in material and workmanship.
2. Dispensing volumes vary based on the period and are affected by temperature and pressure changes.

Grease Types
1. Various grease types are available, including extreme pressure, high speed, food grade, and multipurpose lubricants.
2. Each type is designed for specific applications, such as low temperature or high vibration resistance.

Contact Information
Pulsarlube USA, Inc., 1480 Howard Street, Elk Grove Village, IL 60007, USA. TEL: 1-847-593-5300, FAX: 1-847-593-5303, www.pulsarlube.com, [email protected]
See more

Catalog excerpts

Operation manual E-1

Product Details Installation/Disposal Guidelines Mounting Installations High backpressure can cause a delay in dispensing (must be under 5 bar). Housing Cap Battery Cover Mode Selector Remove contaminants around the lube point. Firmly push the Mode Selector into the slot of the desired period. When the selected dispensing period of the Pulsarlube E has completed, remove the lubricator from the application. If the product is installed at a 45° or 90° angle, please use an angle adapter with a diameter greater than or equal to 1/4". Lubricant Reservoir Ensure a clear passage using a manual grease gun. Note1 Remove any hardened grease by purging the lube point with a manual grease gun. Note2 The grease in the equipment and the grease contained in the unit should be the same or compatible. Turn the housing cap counterclockwise and unscrew the cap. To position the window properly, align the on the housing cap with the on the body. The Pulsarlube E is an eco-friendly product that can be disposed of separately. Turn the housing cap counterclockwise to disassemble the product for proper disposal. Using a hand tool such as a flat-head screwdriver, detach the PCB from the unit. Connecting Thread (1/4" PT) Protector Remove the grease nipple and install appropriate adaptors. Pull out the red Mode Selector from the default OFF position. Note the installation date and the scheduled date of lube cycle completion on the label of the Pulsarlube E. Note Please note there is a delay before the actual dispensing starts. It may take up to 1~3 weeks for enough gas to be formed depending on the dispensing setting & installation condition. Unscrew the screws to remove the battery cover. Dispose of remaining plastic components complying with local regulations for recycling. Warning Do not cut, puncture, or reuse lubricator. For remote installation using an 8mm O.D. tubing, keep the maximum distance at 1m (3ft) or less.

 Open the catalog to page 1
Operation manual E-2

Pulsarlube E Standard Lubricants Grease Grease Type Multi Purpose Product Certifications Description High performance multipurpose lubricant Heavy Duty High Speed Excellent extreme pressure lubricant containing solid lubricants Superior high speed (over 3,000 rpm) or high DN lubricant NSF H1 registered food grade lubricant High Temperature High oxidation stability lubricant Multi Purpose with MoS 2 Multipurpose lubricant fortified with extreme pressure additives and MoS 2 Synthetic lubricant for extreme low temp applications (below 15˚C) Electric Motor Bearing High vibration-resistance lubricant...

 Open the catalog to page 2

Archived catalogs

  1. Pulsarlube E

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.