The Electrochemical Automatic Single Point Lubricator (SPL), specifically the Pulsarlube C model, is designed to extend the life of bearings in industrial applications by providing a precise and predictable supply of lubricant. It utilizes an electrochemical reaction to generate inert Nitrogen gas for dispensing lubricant, offering a safer alternative to traditional methods that use combustible Hydrogen gas.
Operating Principles
The device features a microprocessor-controlled system with a programmed logic circuit, offering four variable dispensing rates. It includes a user-friendly LED panel and is water submergible, ensuring accurate and reliable lubricant dispensing.
Features
- Operating Temperature: -20˚C to 60˚C (-4˚F to 140˚F)
- Maximum Working Pressure: 5.0 kgf/cm² (70 psi)
- Grease Capacity: 125cc or 250cc
- Anti-Explosive Certificate: Ex ia IIB T4
- Available Greases: Multipurpose, High Temperature, High Speed, Food Grade, Heavy Duty
Applications
The SPL is ideal for environments where access is hazardous, contamination is present, or there is insufficient staff for regular lubrication.
Gas Generation Cells
The gas production rate is directly related to the current reduced into the electrolyte. Pressure is generated based on resistance to flow, with no flow resulting in pressure and no resistance resulting in no pressure.
Installation Procedure
1. Check application requirements.
2. Prepare unit and accessories.
3. Remove grease nipple and install the unit.
4. Turn on the unit and select the mode.
5. Ensure the unit is operational within two weeks.
6. Address any operational issues.
Mode Settings Guidelines
To start, press and lock the green button, then select the dispensing mode using the red button. The LED will blink every 7 seconds to indicate operation.
Installation Notes
- Remove contaminants before installation.
- Install one unit per bearing point.
- Bearings larger than 120mm require two units with a non-return valve.
- Install one unit per nipple if a bearing has multiple nipples.
Ordering Information
Models available: KLT100C / PL1 (125cc) and KLT200C / PL1 (250cc). Specify the grease type when ordering.
See more

Catalog excerpts

Leaflet Pulsarlube C-1

Electrochemical Automatic Single Point Lubricator KLT200C The Single-Point Lubricator (SPL) is one of how to extend the life of the bearing in the manufacturing process. Pulsarlube C, Is the New Generation of electrochemical, Automatic, SPL, and is designed to ensure a precise, predictable, and fresh supply of lubricant in a wide variety of Industrial applications. Pulsarlube C delivers a self contained (pre-packed) lubricant, under pressure, by means of a controlled reaction that generates inert Nitrogen (N2) gas. Unlike traditional gas charged lubricators using combustible Hydrogen (H2) gas generation as the result of metal / acid reaction. Pulsarlube C uses an inert Nitrogen gas generation co trolled by a Microprocessor, which is similar to safety airbag technology widely used in vehicles. Operating Principles œ Simple operation œ Microprocessor inside œ Programmed logic circuit œ 4(Four) variable dispensing rates œ Water Submergible œ User-friendly LED panel œ Accurate / Reliable dispensing œ High Performance Lubricant Features Operating Temp -20¢ªC ~ 60¢ªC (-4¢ªF ~ 140¢ªF ) Max working pressure 5.0 kgf/ (70 psi) Grease capacity 125cc / 250cc Anti Explosive Certificate Ex ia IIB T4 5 Standard Greases Multipurpose/High Temperature High Speed/Food Grade/Heavy Duty Specifications Common applications include œ Where access is hazardous or inconvenient œ Contamination is present œ Where there is insufficient staff to guarantee lubrication Applications

 Open the catalog to page 1
Leaflet Pulsarlube C-2

KLT200C Pulsarlube USA, Inc. 4312 DiPaolo Center, Glenview, IL 60025, USA TEL: 1-847-795-0591 FAX: 1-847-795-0119 www.pulsarlubeusa.com [email protected] Gas Generation Cells: Liner gas production rate. Volume of Gas produced in direct equation of current reduced into electrolyte. Pressure generated is result of resistance pressure equals resistance t flow. No Flow = Pressure No resistance = No Pressure Details Shaft Diameter 102~165mm 4”~ 6 1/2” N / A - 1month 8.3 90~101mm 3 1/2”~ 4” 1month 4.2 N / A - 77~89mm 3”~ 3 1/2” N / A - 3months 2.8 65~76mm 2 1/2”~ 3” 3months 1.4 6months 1.4 51~64mm...

 Open the catalog to page 2

Archived catalogs

  1. Pulsarlube E

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.