

Catalog excerpts

FLOWCERT High MCERT’s Class 1 Accuracy on flumes, weirs, and AreaVelocity applications The industry’s highest accuracy, noncontacting, ultrasonic measurement of open channel flows. Designed for flumes and weirs, FlowCERT gives temperatureindependent, reliable measurement, and logging facilities. It includes five alarm / control relays plus 4-20mA output, data logging, digital input with the ability to accept a velocity sensor input for non-PMD applications. Programming the unit is a simple, menu-driven process. MCERTs class 1 approval when used with DUET. Open Channel Flow with NO Primary Measuring Device (PMD) The FlowCERT unit can be combined with a MicroFlow or a Speedy for velocity measurement. For Area-Velocity measurement, FlowCERT provides both contacting and noncontacting options. Combine a MicroFlow and a dB transducer for non-contacting applications and the Speedy for a contacting solution. Open Channel Flow WITH a Primary Measuring Device (PMD) Primary measuring devices include application assets like flumes or weirs. When you have an application with one of these already installed, FlowCERT can be combined with dB transducers from a dBMACH3, all the way up to a dB15. For those applications that require MCERT certified accuracy, FlowCERT can be combined with the DUET transducer enabling it to become the most accurate MCERT system in the world. THE RIGHT METER FOR • High Accuracy • Influent/ Flow on Flumes and Weirs • Area-Velocity Applications • Open Channels Effluent Flow Monitoring Discharge Monitoring Unit Software & Data Logging Pulsar’s Data Logger provides wall mounted Ultra Controllers with data logging functionality, it records and stores a wealth of information onto the supplied 8 GB micro SD card. Log intervals can be user selected. Files are compatible with standard spreadsheet software. The Ultra Software Package is a powerful tool that can be used alongside the data logging board, providing the ability to program the FlowCERT data logging facility, download, view, and export stored data. The software is an optional product and is supplied with a USB/RJ11 cable for connecting your PC directly to the FlowCERT.
Open the catalog to page 1
Area-Velocity Measurement / Open Channel Flow Measurement with no Primary Measuring Device FlowCERT can be combined with either a MicroFlow or Speedy for velocity measurement. Or for area-velocity flow measurement FlowCERT can be used with a MicroFlow and dB transducer for a non-contacting solution or with Speedy for a contacting solution. Open Channel Flow Measurement with a Primary Measuring Device When you have an application with a primary measuring device (PMD), FlowCERT can be combined with dB transducers up to a dB15. For MCERTS certified applications, FlowCERT can be combined with...
Open the catalog to page 2
Technical Specifications PHYSICAL Mounting Option: Controller Body Dimensions: Weight: Standard Wall Mount: 235 mm x 184 mm x 120 mm (9.3 in x 7.2 in x 4.7 in) Nominal 1 kg (2.2 lb) Enclosure Material/ Description: Polycarbonate, flame resistant to UL94-5V Transducer Cable Extensions: Cable Entry Detail: Maximum Separation: Max. & Min. Temperature (Electronics): Flammable Atmosphere Approval: CE Approval: 10 cable entry knock outs, 5 x M20, 1 x M16 underside, x 18 mm (0.7 in) dia (PG11) at rear IP65 / NEMA 4X -20 °C to +50 °C (-4 °F to +120 °F) Safe area: compatible with approved dB...
Open the catalog to page 3
Onboard Programming: Programming Security: Via passcode (user selectable and adjustable) Programmed Data Integrity: Via non-volatile RAM, plus backup SUPPLY Power Supply: 115 V AC +5% / -10% 50/60 Hz, 230 V AC +5% / -10% 50/60 Hz, 22-28 V DC, 10 W maximum power (typically 6 W) FlowCERT Drawing FlowCERT Cable Entry Delivering the Measure of Possibility Pulsar Measurement offers worldwide professional support for all of our products, and our network of global partners all offer full support and training. Our facilities in Malvern, UK and Largo, USA are home to technical support teams who are...
Open the catalog to page 4All Pulsar Measurement catalogs and technical brochures
-
PULSARGUARD 2010 SERIES
2 Pages
-
PULSARGUARD 2001 SAND SENSOR
4 Pages
-
REFLECT 2-wire Radar Sensor
4 Pages
-
MICROFLOW
2 Pages
-
FLOW PULSE
2 Pages
-
Quantum 3 Sales Brochure
4 Pages
-
Quantum 2 Sales Brochure
4 Pages
-
IMP Sales Brochure
4 Pages
-
IMP Lite Sales Brochure
4 Pages
-
IMP I.S. Sales Brochure
4 Pages
-
Blackbox Level Controller
4 Pages
-
The Ultimate Controller
4 Pages
-
Radar Sensors
4 Pages
-
dB Ultrasonic Sensors
4 Pages
-
Ultra 4 Sales Brochure
4 Pages
-
SFM 6.1 Slurry Flow Meter
4 Pages
-
Open Channel Flow Monitors
2 Pages
-
ISM 5.0 Insertion Magmeter
4 Pages
-
DFS 5.1 Doppler Flow Switch
4 Pages
-
Model DFM 6.1
4 Pages
-
AVFM 6.1
4 Pages
-
TTFM 6.1
4 Pages